61 research outputs found

    Modifiable predictors of ventricular ectopy in the community

    Get PDF
    Background Premature ventricular contractions (PVCs) predict heart failure and death. Data regarding modifiable risk factors for PVCs are scarce. Methods and Results We studied 1424 Cardiovascular Health Study participants randomly assigned to 24-hour Holter monitoring. Demographics, comorbidities, habits, and echocardiographic measurements were examined as predictors of PVC frequency and, among 845 participants, change in PVC frequency 5 years later. Participants exhibited a median of 0.6 (interquartile range, 0.1-7.1) PVCs per hour. Of the more directly modifiable characteristics and after multivariable adjustment, every SD increase in systolic blood pressure was associated with 9% more PVCs (95% confidence interval [CI], 2%-17%; P=0.01), regularly performing no or low-intensity exercise compared with more physical activity was associated with ≈15% more PVCs (95% CI, 3-25%; P=0.02), and those with a history of smoking exhibited an average of 18% more PVCs (95% CI, 3-36%; P=0.02) than did never smokers. After 5 years, PVC frequency increased from a median of 0.5 (IQR, 0.1-4.7) to 1.2 (IQR, 0.1-13.8) per hour ( P<0.0001). Directly modifiable predictors of 5-year increase in PVCs, described as the odds per each quintile increase in PVCs, included increased diastolic blood pressure (odds ratio per SD increase, 1.16; 95% CI, 1.02-1.31; P=0.02) and a history of smoking (OR, 1.31; 95% CI, 1.02-1.68; P=0.04). Conclusions Enhancing physical activity, smoking cessation, and aggressive control of blood pressure may represent fruitful strategies to mitigate PVC frequency and PVC-associated adverse outcomes

    Ectopy on a single 12‐lead ECG, incident cardiac myopathy, and death in the community

    Get PDF
    BackgroundAtrial fibrillation and heart failure are 2 of the most common diseases, yet ready means to identify individuals at risk are lacking. The 12-lead ECG is one of the most accessible tests in medicine. Our objective was to determine whether a premature atrial contraction observed on a standard 12-lead ECG would predict atrial fibrillation and mortality and whether a premature ventricular contraction would predict heart failure and mortality.Methods and resultsWe utilized the CHS (Cardiovascular Health) Study, which followed 5577 participants for a median of 12 years, as the primary cohort. The ARIC (Atherosclerosis Risk in Communities Study), the replication cohort, captured data from 15 792 participants over a median of 22 years. In the CHS, multivariable analyses revealed that a baseline 12-lead ECG premature atrial contraction predicted a 60% increased risk of atrial fibrillation (hazard ratio, 1.6; 95% CI, 1.3-2.0; P<0.001) and a premature ventricular contraction predicted a 30% increased risk of heart failure (hazard ratio, 1.3; 95% CI, 1.0-1.6; P=0.021). In the negative control analyses, neither predicted incident myocardial infarction. A premature atrial contraction was associated with a 30% increased risk of death (hazard ratio, 1.3; 95% CI, 1.1-1.5; P=0.008) and a premature ventricular contraction was associated with a 20% increased risk of death (hazard ratio, 1.2; 95% CI, 1.0-1.3; P=0.044). Similarly statistically significant results for each analysis were also observed in ARIC.ConclusionsBased on a single standard ECG, a premature atrial contraction predicted incident atrial fibrillation and death and a premature ventricular contraction predicted incident heart failure and death, suggesting that this commonly used test may predict future disease

    Randomized trial of conventional transseptal needle versus radiofrequency energy needle puncture for left atrial access (the TRAVERSE-LA study).

    Get PDF
    BackgroundTransseptal puncture is a critical step in achieving left atrial (LA) access for a variety of cardiac procedures. Although the mechanical Brockenbrough needle has historically been used for this procedure, a needle employing radiofrequency (RF) energy has more recently been approved for clinical use. We sought to investigate the comparative effectiveness of an RF versus conventional needle for transseptal LA access.Methods and resultsIn this prospective, single-blinded, controlled trial, 72 patients were randomized in a 1:1 fashion to an RF versus conventional (BRK-1) transseptal needle. In an intention-to-treat analysis, the primary outcome was time required for transseptal LA access. Secondary outcomes included failure of the assigned needle, visible plastic dilator shavings from needle introduction, and any procedural complication. The median transseptal puncture time was 68% shorter using the RF needle compared with the conventional needle (2.3 minutes [interquartile range {IQR}, 1.7 to 3.8 minutes] versus 7.3 minutes [IQR, 2.7 to 14.1 minutes], P = 0.005). Failure to achieve transseptal LA access with the assigned needle was less common using the RF versus conventional needle (0/36 [0%] versus 10/36 [27.8%], P < 0.001). Plastic shavings were grossly visible after needle advancement through the dilator and sheath in 0 (0%) RF needle cases and 12 (33.3%) conventional needle cases (P < 0.001). There were no differences in procedural complications (1/36 [2.8%] versus 1/36 [2.8%]).ConclusionsUse of an RF needle resulted in shorter time to transseptal LA access, less failure in achieving transseptal LA access, and fewer visible plastic shavings

    Ventricular Ectopy as a Predictor of Heart Failure and Death

    Get PDF
    AbstractBackgroundStudies of patients presenting for catheter ablation suggest that premature ventricular contractions (PVCs) are a modifiable risk factor for congestive heart failure (CHF). The relationship among PVC frequency, incident CHF, and mortality in the general population remains unknown.ObjectivesThe goal of this study was to determine whether PVC frequency ascertained using a 24-h Holter monitor is a predictor of a decrease in the left ventricular ejection fraction (LVEF), incident CHF, and death in a population-based cohort.MethodsWe studied 1,139 Cardiovascular Health Study (CHS) participants who were randomly assigned to 24-h ambulatory electrocardiography (Holter) monitoring and who had a normal LVEF and no history of CHF. PVC frequency was quantified using Holter studies, and LVEF was measured from baseline and 5-year echocardiograms. Participants were followed for incident CHF and death.ResultsThose in the upper quartile versus the lowest quartile of PVC frequency had a multivariable-adjusted, 3-fold greater odds of a 5-year decrease in LVEF (odds ratio [OR]: 3.10; 95% confidence interval [CI]: 1.42 to 6.77; p = 0.005), a 48% increased risk of incident CHF (HR: 1.48; 95% CI: 1.08 to 2.04; p = 0.02), and a 31% increased risk of death (HR: 1.31; 95% CI: 1.06 to 1.63; p = 0.01) during a median follow-up of >13 years. Similar statistically significant results were observed for PVCs analyzed as a continuous variable. The specificity for the 15-year risk of CHF exceeded 90% when PVCs included at least 0.7% of ventricular beats. The population-level risk for incident CHF attributed to PVCs was 8.1% (95% CI: 1.2% to 14.9%).ConclusionsIn a population-based sample, a higher frequency of PVCs was associated with a decrease in LVEF, an increase in incident CHF, and increased mortality. Because of the capacity to prevent PVCs through medical or ablation therapy, PVCs may represent a modifiable risk factor for CHF and death

    Pharmacologic Prevention of Incident Atrial Fibrillation

    No full text
    corecore