7 research outputs found
A geospatial approach to flash flood hazard mapping in the city of Warangal, Telangana, India
Dense urbanization leading to uncontrolled transformations within settlements result in flash flooding with overflowing drains leading to a greater inconvenience for the public and damage to private properties. Hence mapping of flash floods would be useful in identifying the high-risk flood zones for disaster response and urban services, during emergencies with rainfall events of high intensity. This article aims to prepare a flood hazard map of Warangal Municipal Corporation (WMC) in Telangana State, India. WMC is chronically affected due to a rise in water levels resulting in flash floods, with an increase in encroachments. The factors considered in this study are rainfall (curve number), surface slope and surface roughness, type of soil, and distance to main channel, drainage density, and land use cover. To decide the relative weight of the impact of each flood causative factors an Analytical Hierarchical Process (AHP) was used. Accordingly, a composite Flood Hazard Index (FHI) has been derived by using the multiple-criteria decision-making tools by integrating these into a Geographical Information System (GIS). The Soil and Water Assessment Tool (SWAT) in Quantum GIS (QGIS), which is a hydrological model, was used to evaluate the projection of streamflow over the water basin and model parameters were optimized using water balance equations during calibration and validation periods
Flow Simulation and Storage Assessment in an Ungauged Irrigation Tank Cascade System Using the SWAT Model
In the semi-arid regions of South Asia, tank systems are the major source of irrigation. In India, the Telangana state government has initiated the Mission Kakatiya program to rejuvenate irrigation tank systems. Understanding the hydrological processes that supply water to these systems is critical to the success of these types of programs in India. The current study attempted to comprehend the hydrological processes and flow routing in the Salivagu watershed tank cascade system in Telangana. There are a lot of ungauged tank cascade systems in this region. Soil Water Assessment Tool (SWAT), a physically-based model, was used to simulate flow patterns in the Salivagu watershed with and without tank systems. The geospatially extracted area and volume were used for this study provided by WBIS-Bhuvan-NRSC. Additionally, the Katakshapur Tank Cascade System (KTCS) was chosen to analyze the water availability in each tank using the water balance approach. The Salivagu watershed flow simulation without tanks overestimated streamflow. The volume difference in flow between with and without tank was 606 Mm3, 615.9 Mm3, and 1011 Mm3 in 2017, 2018, and 2019, respectively. The SWAT simulated volumes of the Ramchandrapur and Dharmaraopalle tanks in KTCS were merely satisfied because the tank size was less than 0.7 km2 and the storage capacity was up to 1 Mm3. Due to tank sizes more than 0.8 km2 and capacities greater than 2 Mm3, the Mallampalli and Katakshapur tank simulation findings were in good agreement with WBIS-Bhuvan-NRSC. This research advances our understanding of the hydrological processes in ungauged cascading tank systems in tropical semi-arid regions
Flow Simulation and Storage Assessment in an Ungauged Irrigation Tank Cascade System Using the SWAT Model
In the semi-arid regions of South Asia, tank systems are the major source of irrigation. In India, the Telangana state government has initiated the Mission Kakatiya program to rejuvenate irrigation tank systems. Understanding the hydrological processes that supply water to these systems is critical to the success of these types of programs in India. The current study attempted to comprehend the hydrological processes and flow routing in the Salivagu watershed tank cascade system in Telangana. There are a lot of ungauged tank cascade systems in this region. Soil Water Assessment Tool (SWAT), a physically-based model, was used to simulate flow patterns in the Salivagu watershed with and without tank systems. The geospatially extracted area and volume were used for this study provided by WBIS-Bhuvan-NRSC. Additionally, the Katakshapur Tank Cascade System (KTCS) was chosen to analyze the water availability in each tank using the water balance approach. The Salivagu watershed flow simulation without tanks overestimated streamflow. The volume difference in flow between with and without tank was 606 Mm3, 615.9 Mm3, and 1011 Mm3 in 2017, 2018, and 2019, respectively. The SWAT simulated volumes of the Ramchandrapur and Dharmaraopalle tanks in KTCS were merely satisfied because the tank size was less than 0.7 km2 and the storage capacity was up to 1 Mm3. Due to tank sizes more than 0.8 km2 and capacities greater than 2 Mm3, the Mallampalli and Katakshapur tank simulation findings were in good agreement with WBIS-Bhuvan-NRSC. This research advances our understanding of the hydrological processes in ungauged cascading tank systems in tropical semi-arid regions
Effectiveness and safety of optical coherence tomography-guided PCI in Indian patients with complex lesions: A multicenter, prospective registry
Background: Optical coherence tomography (OCT) is reported to be a feasible and safe imaging modality for the guidance of percutaneous coronary intervention (PCI) of complex lesions. Methods: This multicenter, prospective registry assessed the minimum stent area (MSA) achieved under OCT guidance. A performance goal of 24% improvement in MSA over and above the recommendation set by the European Association of Percutaneous Cardiovascular Interventions Consensus 2018 (4.5 mm2 MSA for non-left main and 3.5 mm2 for small vessels). The incidence of contrast-induced nephropathy was also assessed. Core lab analysis was conducted. Results: Five hundred patients (average age: 59.4 ± 10.1 years; 83% males) with unstable angina (36.8%), NSTEMI (26.4%), and STEMI (22%) were enrolled. The primary endpoint was achieved in 93% of lesions with stent diameter ≥2.75 mm (average MSA: 6.44 mm2) and 87% of lesions with stent diameter ≤2.5 mm (average MSA: 4.56 mm2). The average MSA (with expansion ≥80% cutoff) was 6.63 mm2 and 4.74 mm2 with a stent diameter ≥2.75 mm and ≤2.5 mm, respectively. According to the core lab analysis, the average MSA achieved with a stent diameter ≥2.75 mm and ≤2.5 mm was 6.23 mm2 and 3.95 mm2, respectively (with expansion ≥80% cutoff). Clinically significant serum creatinine was noted in two patients (0.45%). Major adverse cardiac events at 1 year were noted in 1.2% (n = 6) of the patients; all were cardiac deaths. Conclusion: PCI under OCT guidance improves procedural and long-term clinical outcomes in patients with complex lesions not just in a controlled trial environment but also in routine clinical practice
Abstracts of National Conference on Research and Developments in Material Processing, Modelling and Characterization 2020
This book presents the abstracts of the papers presented to the Online National Conference on Research and Developments in Material Processing, Modelling and Characterization 2020 (RDMPMC-2020) held on 26th and 27th August 2020 organized by the Department of Metallurgical and Materials Science in Association with the Department of Production and Industrial Engineering, National Institute of Technology Jamshedpur, Jharkhand, India.
Conference Title: National Conference on Research and Developments in Material Processing, Modelling and Characterization 2020Conference Acronym: RDMPMC-2020Conference Date: 26–27 August 2020Conference Location: Online (Virtual Mode)Conference Organizer: Department of Metallurgical and Materials Engineering, National Institute of Technology JamshedpurCo-organizer: Department of Production and Industrial Engineering, National Institute of Technology Jamshedpur, Jharkhand, IndiaConference Sponsor: TEQIP-