57 research outputs found

    Survival following coronary angioplasty versus coronary artery bypass surgery in anatomic subsets in which coronary artery bypass surgery improves survival compared with medical therapy Results from the Bypass Angioplasty Revascularization Investigation (BARI)

    Get PDF
    AbstractOBJECTIVESWe sought to compare survival after coronary artery bypass graft (CABG) and percutaneous transluminal coronary angioplasty (PTCA) in high-risk anatomic subsets.BACKGROUNDCompared with medical therapy, CABG decreases mortality in patients with three-vessel disease and two-vessel disease involving the proximal left anterior descending artery (LAD), particularly if left ventricular (LV) dysfunction is present. How survival after PTCA and CABG compares in these high-risk anatomic subsets is unknown.METHODSIn the Bypass Angioplasty Revascularization Investigation (BARI), 1,829 patients with multivessel disease were randomized to an initial strategy of PTCA or CABG between 1988 and 1991. Stents and IIb/IIIa inhibitors were not utilized. Since patients in BARI with diabetes mellitus had greater survival with CABG, separate analyses of patients without diabetes were performed.RESULTSSeven-year survival among patients with three-vessel disease undergoing PTCA and CABG (n = 754) was 79% versus 84% (p = 0.06), respectively, and 85% versus 87% (p = 0.36) when only non-diabetics (n = 592) were analyzed. In patients with three-vessel disease and reduced LV function (ejection fraction <50%), seven-year survival was 70% versus 74% (p = 0.6) in all PTCA and CABG patients (n = 176), and 82% versus 73% (p = 0.29) among non-diabetic patients (n = 124). Seven-year survival was 87% versus 84% (p = 0.9) in all PTCA and CABG patients (including diabetics) with two-vessel disease involving the proximal LAD (n = 352), and 78% versus 71% (p = 0.7) in patients with two-vessel disease involving the proximal LAD with reduced LV function (n = 72).CONCLUSIONIn high–risk anatomic subsets in which survival is prolonged by CABG versus medical therapy, revascularization by PTCA and CABG yielded equivalent survival over seven years

    A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators.

    Get PDF
    BACKGROUND: Coronary-stent placement is a new technique in which a balloon-expandable, stainless-steel, slotted tube is implanted at the site of a coronary stenosis. The purpose of this study was to compare the effects of stent placement and standard balloon angioplasty on angiographically detected restenosis and clinical outcomes. METHODS: We randomly assigned 410 patients with symptomatic coronary disease to elective placement of a Palmaz-Schatz stent or to standard balloon angioplasty. Coronary angiography was performed at base line, immediately after the procedure, and six months later. RESULTS: The patients who underwent stenting had a higher rate of procedural success than those who underwent standard balloon angioplasty (96.1 percent vs. 89.6 percent, P = 0.011), a larger immediate increase in the diameter of the lumen (1.72 +/- 0.46 vs. 1.23 +/- 0.48 mm, P \u3c 0.001), and a larger luminal diameter immediately after the procedure (2.49 +/- 0.43 vs. 1.99 +/- 0.47 mm, P \u3c 0.001). At six months, the patients with stented lesions continued to have a larger luminal diameter (1.74 +/- 0.60 vs. 1.56 +/- 0.65 mm, P = 0.007) and a lower rate of restenosis (31.6 percent vs. 42.1 percent, P = 0.046) than those treated with balloon angioplasty. There were no coronary events (death; myocardial infarction; coronary-artery bypass surgery; vessel closure, including stent thrombosis; or repeated angioplasty) in 80.5 percent of the patients in the stent group and 76.2 percent of those in the angioplasty group (P = 0.16). Revascularization of the original target lesion because of recurrent myocardial ischemia was performed less frequently in the stent group than in the angioplasty group (10.2 percent vs. 15.4 percent, P = 0.06). CONCLUSIONS: In selected patients, placement of an intracoronary stent, as compared with balloon angioplasty, results in an improved rate of procedural success, a lower rate of angiographically detected restenosis, a similar rate of clinical events after six months, and a less frequent need for revascularization of the original coronary lesion

    The Mid-infrared Instrument for JWST and Its In-flight Performance

    Get PDF
    The Mid-Infrared Instrument (MIRI) extends the reach of the James Webb Space Telescope (JWST) to 28.5 ÎŒm. It provides subarcsecond-resolution imaging, high sensitivity coronagraphy, and spectroscopy at resolutions of λ/Δλ ∌ 100-3500, with the high-resolution mode employing an integral field unit to provide spatial data cubes. The resulting broad suite of capabilities will enable huge advances in studies over this wavelength range. This overview describes the history of acquiring this capability for JWST. It discusses the basic attributes of the instrument optics, the detector arrays, and the cryocooler that keeps everything at approximately 7 K. It gives a short description of the data pipeline and of the instrument performance demonstrated during JWST commissioning. The bottom line is that the telescope and MIRI are both operating to the standards set by pre-launch predictions, and all of the MIRI capabilities are operating at, or even a bit better than, the level that had been expected. The paper is also designed to act as a roadmap to more detailed papers on different aspects of MIRI

    The Science Performance of JWST as Characterized in Commissioning

    Full text link
    This paper characterizes the actual science performance of the James Webb Space Telescope (JWST), as determined from the six month commissioning period. We summarize the performance of the spacecraft, telescope, science instruments, and ground system, with an emphasis on differences from pre-launch expectations. Commissioning has made clear that JWST is fully capable of achieving the discoveries for which it was built. Moreover, almost across the board, the science performance of JWST is better than expected; in most cases, JWST will go deeper faster than expected. The telescope and instrument suite have demonstrated the sensitivity, stability, image quality, and spectral range that are necessary to transform our understanding of the cosmos through observations spanning from near-earth asteroids to the most distant galaxies.Comment: 5th version as accepted to PASP; 31 pages, 18 figures; https://iopscience.iop.org/article/10.1088/1538-3873/acb29

    The James Webb Space Telescope Mission

    Full text link
    Twenty-six years ago a small committee report, building on earlier studies, expounded a compelling and poetic vision for the future of astronomy, calling for an infrared-optimized space telescope with an aperture of at least 4m4m. With the support of their governments in the US, Europe, and Canada, 20,000 people realized that vision as the 6.5m6.5m James Webb Space Telescope. A generation of astronomers will celebrate their accomplishments for the life of the mission, potentially as long as 20 years, and beyond. This report and the scientific discoveries that follow are extended thank-you notes to the 20,000 team members. The telescope is working perfectly, with much better image quality than expected. In this and accompanying papers, we give a brief history, describe the observatory, outline its objectives and current observing program, and discuss the inventions and people who made it possible. We cite detailed reports on the design and the measured performance on orbit.Comment: Accepted by PASP for the special issue on The James Webb Space Telescope Overview, 29 pages, 4 figure
    • 

    corecore