22 research outputs found

    Oxidative stress in hemodialysis patients: Is NADPH oxidase complex the culprit?

    Get PDF
    Oxidative stress in hemodialysis patients: Is NADPH oxidase complex the culprit?Oxidative stress results from an imbalance between oxidant production, including reactive oxygen species (ROS), reactive nitrogen species (RNS), chlorinated compounds, and antioxidant defense mechanisms. Most reports prove that oxidative stress is present in ESRD patients. Several studies tend to accreditate the hypothesis by which oxidative stress is a strong co-factor for the development of complications related to long-term HD such as atherosclerosis, amyloidosis, malnutrition, anemia, and infection.In order to evaluate the rationale for curative action against oxidative damage in chronic renal failure patients, we reviewed the putative factors involved in this process. Antioxidant systems are severely impaired in uremic patients and gradually altered with the degree of renal failure. Moreover, the inflammatory state caused by the hemoincompatibility of the dialysis system plays a critical role in the activation of NADPH oxidase, aggravating the pro-oxidant status of uremic patients.Prevention of ROS overproduction by improvement of dialysis biocompatibility, an important component of adequate dialysis, might be completed by antioxidant supplementation

    Anaphylactoid reactions during hemodialysis in sheep are ACE inhibitor dose-dependent and mediated by bradykinin

    Get PDF
    Anaphylactoid reactions during hemodialysis in sheep are ACE inhibitor dose-dependent and mediated by bradykinin. Anaphylactoid reactions (AR) have been attributed to the generation of bradykinin (BK) when AN69 membranes are used together with angiotensin converting enzyme (ACE) inhibitors during hemodialysis. However, conclusive evidence for the involvement of the BK as the mediator of these AR is still lacking. This study examined the degree of contact activation in an animal model caused by three PAN membranes—AN69, PAN DX, and SPAN—and the effects of different doses of the ACE inhibitor enalapril (ENA) and the BK B2-receptor antagonist icatibant on AR during hemodialysis. Six sheep were dialyzed for one hour with or without ENA pre-treatment using the different membranes in random order. Severe AR were observed only during hemodialysis with AN69 dialyzers together with ENA pre-treatment; the severity of AR increased with the ENA dose. Mild hypotension was noted during hemodialysis with AN69 without ACE inhibition and with PAN DX and 20 mg ENA. Compared to pre-dialysis values, maximum generation of BK after blood passage through the dialyzer was found at five minutes: 73-fold (AN69 without ENA), 161-fold (AN69 with 10 mg ENA), 97-fold (AN69 with 20 mg ENA), 108-fold (AN69 with 30 mg ENA), 154-fold (AN69 with 30 mg ENA and 0.1 mg/kg icatibant), 18-fold (PAN DX without ENA), and 42-fold (PAN DX with 20 mg ENA). Elevated BK levels in arterial blood were detected during hemodialysis with AN69 membranes even without ACE inhibition (2.5-fold); pre-treatment with 20 mg ENA further increased arterial BK concentrations (4-fold). Furthermore, a marked decline of prekallikrein and high molecular weight kininogen concentrations was noted for both AN69 and PAN DX membranes. Anaphylactoid reactions during hemodialysis were completely prevented by icatibant even after pre-treatment with ENA and in the presence of high BK concentrations. Concentrations of prekallikrein, high molecular weight kininogen, and BK remained unchanged and no AR were observed during hemodialysis with SPAN and pre-treatment with 20 mg ENA. Our findings confirm that AR during hemodialysis with the negatively charged AN69 membrane are mediated by BK, since they can be prevented by the BK B2-receptor antagonist icatibant

    Associations between depressive symptoms and disease progression in older patients with chronic kidney disease: results of the EQUAL study

    Get PDF
    Background Depressive symptoms are associated with adverse clinical outcomes in patients with end-stage kidney disease; however, few small studies have examined this association in patients with earlier phases of chronic kidney disease (CKD). We studied associations between baseline depressive symptoms and clinical outcomes in older patients with advanced CKD and examined whether these associations differed depending on sex. Methods CKD patients (>= 65 years; estimated glomerular filtration rate <= 20 mL/min/1.73 m(2)) were included from a European multicentre prospective cohort between 2012 and 2019. Depressive symptoms were measured by the five-item Mental Health Inventory (cut-off <= 70; 0-100 scale). Cox proportional hazard analysis was used to study associations between depressive symptoms and time to dialysis initiation, all-cause mortality and these outcomes combined. A joint model was used to study the association between depressive symptoms and kidney function over time. Analyses were adjusted for potential baseline confounders. Results Overall kidney function decline in 1326 patients was -0.12 mL/min/1.73 m(2)/month. A total of 515 patients showed depressive symptoms. No significant association was found between depressive symptoms and kidney function over time (P = 0.08). Unlike women, men with depressive symptoms had an increased mortality rate compared with those without symptoms [adjusted hazard ratio 1.41 (95% confidence interval 1.03-1.93)]. Depressive symptoms were not significantly associated with a higher hazard of dialysis initiation, or with the combined outcome (i.e. dialysis initiation and all-cause mortality). Conclusions There was no significant association between depressive symptoms at baseline and decline in kidney function over time in older patients with advanced CKD. Depressive symptoms at baseline were associated with a higher mortality rate in men

    Binding Affinity and Capacity for the Uremic Toxin Indoxyl Sulfate

    Get PDF
    Protein binding prevents uremic toxins from removal by conventional extracorporeal therapies leading to accumulation in maintenance dialysis patients. Weakening of the protein binding may enhance the dialytic elimination of these toxins. In ultrafiltration and equilibrium dialysis experiments, different measures to modify the plasma binding affinity and capacity were tested: (i), increasing the sodium chloride (NaCl) concentration to achieve a higher ionic strength; (ii), increasing the temperature; and (iii), dilution. The effects on the dissociation constant K-D and the protein bound fraction of the prototypical uremic toxin indoxyl sulfate (IS) in plasma of healthy and uremic individuals were studied. Binding of IS corresponded to one site binding in normal plasma. K-D increased linearly with the NaCl concentration between 0.15 (K-D = 13.2 +/- 3.7 mu M) and 0.75 M (K-D = 56.2 +/- 2.0 mu M). Plasma dilution further reduced the protein bound toxin fraction by lowering the protein binding capacity of the plasma. Higher temperatures also decreased the protein bound fraction of IS in human plasma. Increasing the NaCl concentration was effective to weaken the binding of IS also in uremic plasma: the protein bound fraction decreased from 89% +/- 3% to 81% +/- 3% at 0.15 and 0.75 M NaCl, respectively. Dilution and increasing the ionic strength and temperature enhance the free fraction of IS allowing better removal of the substance during dialysis. Applied during clinical dialysis, this may have beneficial effects on the long-term outcome of maintenance dialysis patients

    Clinical performance comparison of two medium cut-off dialyzers

    No full text
    Introduction Medium-cut-off (MCO) dialyzers may beneficially impact outcomes in patients on hemodialysis. Methods In a randomized, controlled trial in maintenance hemodialysis patients, the new Nipro ELISIO-17HX MCO dialyzer was compared to the Baxter Theranova 400 filter regarding middle molecule removal. Furthermore, the suitability of two assays for free lambda-light chain (λFLC) detection (Freelite vs. N-Latex) was verified. Results ELISIO-HX achieved slightly lower reduction ratios for ÎČ2-microglobulin (71.8 ± 6.0 vs. 75.3 ± 5.8%; p = 0.001), myoglobin (54.7 ± 8.6 vs. 64.9 ± 8.7%; p < 0.001), and kappa-FLC (62.1 ± 8.8 vs. 56.3 ± 7.7%; p = 0.021). λFLC reduction ratios were more conclusive with the Freelite assay and not different between ELISIO-HX and Theranova (28.4 ± 3.9 vs. 38.7 ± 13.4%; p = 0.069). The albumin loss of Theranova was considerably higher (2.14 ± 0.45 vs. 0.77 ± 0.25 g; p = 0.001) and the Global Removal ScoreLoss alb largely inferior (30.6 ± 7.4 vs. 82.4 ± 29.2%/g; p = 0.006) to ELISIO-HX. Conclusions The new ELISIO-HX expands the choice of dialyzers for MCO hemodialysis

    A multi-center, prospective, open-label, 8-week study of certoparin for anticoagulation during maintenance hemodialysis – the membrane study

    Get PDF
    Background Adequate anticoagulation is prerequisite for effective hemodialysis to prevent clotting in the extracorporeal circuit. We aimed providing first data on the efficacy and safety of the low-molecular-weight heparin certoparin in this setting. Methods Multicenter, open-label, 8-week trial. Patients received a single dose of 3,000 IU certoparin i.v. with additional titration steps of 600 IU and/or continuous infusion if necessary. Results 120 patients were screened, 109 enrolled (median age 71; range 26–90 years) and 106 available for efficacy analyses. The percentage of unsatisfactory dialysis results at 8 weeks due to clotting or bleeding, was 1.9% (n = 2/106; 95% confidence interval [CI] 0.23–6.65%); no major bleeding. 1.9% had moderate/severe clotting in the lines/bubble catcher and 2.8% in the dialyser at week 8. 15.7 ± 14.3% of the dialysis filters’ visual surface area was showing redness. In subgroups of patients receiving median doses of 3000 ± 0, 3000 (2400–6000) and 4200 (3000–6600) IU, plasma aXa levels at baseline, 4 and 8 weeks were 0.24 [95%CI 0.21–0.27], 0.33 [0.27–0.40] and 0.38 [0.33–0.45] aXa IU/ml at 2 h. C48hC_{48h} was 0.01 [0.01–0.02] aXa IU at all visits. At baseline and 4 weeks AUC0−48hAUC_{0-48h} was 2.66 [2.19–3.24] and 3.66 [3.00–4.45] aXa IU*h/ml. In 3.0% of dialyses (n = 83/2724) prolonged fistula compression times were documented. Eight patients (7.34%) had at least one episode of minor bleeding. 4) 85.3% of patients had any adverse event, 9.2% were serious without suspected drug relation; and in 32 patients a drug-relation was suspected. Conclusions Certoparin appears effective and safe for anticoagulation in patients undergoing maintenance hemodialysis

    Differences in Dialysis Efficacy Have Limited Effects on Protein-Bound Uremic Toxins Plasma Levels over Time

    Get PDF
    The protein-bound uremic toxins para-cresyl sulfate (pCS) and indoxyl sulfate (IS) are associated with cardiovascular disease in chronic renal failure, but the effect of different dialysis procedures on their plasma levels over time is poorly studied. The present prospective, randomized, cross-over trial tested dialysis efficacy and monitored pre-treatment pCS and IS concentrations in 15 patients on low-flux and high-flux hemodialysis and high-convective volume postdilution hemodiafiltration over six weeks each. Although hemodiafiltration achieved by far the highest toxin removal, only the mean total IS level was decreased at week three (16.6 &plusmn; 12.1 mg/L) compared to baseline (18.9 &plusmn; 13.0 mg/L, p = 0.027) and to low-flux dialysis (20.0 &plusmn; 12.7 mg/L, p = 0.021). At week six, the total IS concentration in hemodiafiltration reached the initial values again. Concentrations of free IS and free and total pCS remained unaltered. Highest beta2-microglobulin elimination in hemodiafiltration (p &lt; 0.001) led to a persistent decrease of the plasma levels at week three and six (each p &lt; 0.001). In contrast, absent removal in low-flux dialysis resulted in rising beta2-microglobulin concentrations (p &lt; 0.001). In conclusion, this trial demonstrated that even large differences in instantaneous protein-bound toxin removal by current extracorporeal dialysis techniques may have only limited impact on IS and pCS plasma levels in the longer term

    Enhancement of solute clearance using pulsatile push-pull dialysate flow for the Quanta SC+: A novel clinic-to-home haemodialysis system.

    No full text
    BACKGROUND AND OBJECTIVE:The SC+ haemodialysis system developed by Quanta Dialysis Technologies is a small, easy-to-use dialysis system designed to improve patient access to self-care and home haemodialysis. A prototype variant of the standard SC+ device with a modified fluidic management system generating a pulsatile push-pull dialysate flow through the dialyser during use has been developed for evaluation. It was hypothesized that, as a consequence of the pulsatile push-pull flow through the dialyser, the boundary layers at the membrane surface would be disrupted, thereby enhancing solute transport across the membrane, modifying protein fouling and maintaining the surface area available for mass and fluid transport throughout the whole treatment, leading to solute transport (clearance) enhancement compared to normal haemodialysis (HD) operation. METHODS:The pumping action of the SC+ system was modified by altering the sequence and timings of the valves and pumps associated with the flow balancing chambers that push and pull dialysis fluid to and from the dialyser. Using this unique prototype device, solute clearance performance was assessed across a range of molecular weights in two related series of laboratory bench studies. The first measured dialysis fluid moving across the dialyser membrane using ultrasonic flowmeters to establish the validity of the approach; solute clearance was subsequently measured using fluorescently tagged dextran molecules as surrogates for uraemic toxins. The second study used human blood doped with uraemic toxins collected from the spent dialysate of dialysis patients to quantify solute transport. In both, the performance of the SC+ prototype was assessed alongside reference devices operating in HD and pre-dilution haemodiafiltration (HDF) modes. RESULTS:Initial testing with fluorescein-tagged dextran molecules (0.3 kDa, 4 kDa, 10 kDa and 20 kDa) established the validity of the experimental pulsatile push-pull operation in the SC+ system to enhance clearance and demonstrated a 10 to 15% improvement above the current HD mode used in clinic today. The magnitude of the observed enhancement compared favourably with that achieved using pre-dilution HDF with a substitution fluid flow rate of 60 mL/min (equivalent to a substitution volume of 14.4 L in a 4-hour session) with the same dialyser and marker molecules. Additional testing using human blood indicated a comparable performance to pre-dilution HDF; however, in contrast with HDF, which demonstrated a gradual decrease in solute removal, the clearance values using the pulsatile push-pull method on the SC+ system were maintained over the entire duration of treatment. Overall albumin losses were not different. CONCLUSIONS:Results obtained using an experimental pulsatile push-pull dialysis flow configuration with an aqueous blood analogue and human blood ex vivo demonstrate an enhancement of solute transport across the dialyser membrane. The level of enhancement makes this approach comparable with that achieved using pre-dilution HDF with a substitution fluid flow rate of 60 mL/min (equivalent to a substitution volume of 14.4 L in a 4-hour session). The observed enhancement of solute transport is attributed to the disruption of the boundary layers at the fluid-membrane interface which, when used with blood, minimizes protein fouling and maintains the surface area

    Clinical hemocompatibility of double-filtration lipoprotein apheresis comparing polyethersulfone and ethylene-vinyl alcohol copolymer membranes

    No full text
    Activation of the complement system and leukocytes by blood–membrane interactions may further promote arteriosclerosis typically present in patients on lipoprotein apheresis. As clinical data on the hemocompatibility of lipoprotein apheresis are scarce, a controlled clinical study comparing two different types of plasma separation and fractionation membranes used in double-filtration lipoprotein apheresis was urgently needed, as its outcome may influence clinical decision-making. In a prospective, randomized, crossover controlled trial, eight patients on double-filtration lipoprotein apheresis were subjected to one treatment with recent polyethersulfone (PES) plasma separation and fractionation membranes and one control treatment using a set of ethylene-vinyl alcohol copolymer (EVAL) membranes. White blood cell (WBC) and platelet (PC) counts, complement factor C5a and thrombin–antithrombin III (TAT) concentrations were determined in samples drawn at defined times from different sites of the extracorporeal blood and plasma circuit. With a nadir at 25 minutes, WBCs in EVAL decreased to 33.5 ± 10.7% of baseline compared with 63.8 ± 22.0% at 20 minutes in PES (P < .001). The maximum C5a levels in venous blood reentering the patients were measured at 30 minutes, being 30.0 ± 11.2 ”g/L with EVAL and 12.3 ± 9.0 ”g/L with PES (P < .05). The highest C5a concentrations were found in plasma after the plasma filters (EVAL 56.1 ± 22.0 ”g/L at 15 minutes vs PES 23.3 ± 15.2 ”g/L at 10 minutes; P < .001). PC did not significantly decrease over time with both membrane types, whereas TAT levels did not rise until the end of the treatment without differences between membranes. Regarding lipoprotein(a) and low-density lipoprotein (LDL) cholesterol removal, both membrane sets performed equally. Compared with EVAL, PES membranes cause less leukocyte and complement system activation, the classical parameters of hemocompatibility of extracorporeal treatment procedures, at identical treatment efficacy. Better hemocompatibility may avoid inflammation-promoting effects through blood–material interactions in patients requiring double-filtration lipoprotein apheresis

    A multi-center, prospective, open-label, 8-week study of certoparin for anticoagulation during maintenance hemodialysis – the membrane study

    No full text
    Abstract Background Adequate anticoagulation is prerequisite for effective hemodialysis to prevent clotting in the extracorporeal circuit. We aimed providing first data on the efficacy and safety of the low-molecular-weight heparin certoparin in this setting. Methods Multicenter, open-label, 8-week trial. Patients received a single dose of 3,000 IU certoparin i.v. with additional titration steps of 600 IU and/or continuous infusion if necessary. Results 120 patients were screened, 109 enrolled (median age 71; range 26–90 years) and 106 available for efficacy analyses. The percentage of unsatisfactory dialysis results at 8 weeks due to clotting or bleeding, was 1.9% (n = 2/106; 95% confidence interval [CI] 0.23–6.65%); no major bleeding. 1.9% had moderate/severe clotting in the lines/bubble catcher and 2.8% in the dialyser at week 8. 15.7 ± 14.3% of the dialysis filters’ visual surface area was showing redness. In subgroups of patients receiving median doses of 3000 ± 0, 3000 (2400–6000) and 4200 (3000–6600) IU, plasma aXa levels at baseline, 4 and 8 weeks were 0.24 [95%CI 0.21–0.27], 0.33 [0.27–0.40] and 0.38 [0.33–0.45] aXa IU/ml at 2 h. C48h was 0.01 [0.01–0.02] aXa IU at all visits. At baseline and 4 weeks AUC0-48h was 2.66 [2.19–3.24] and 3.66 [3.00–4.45] aXa IU*h/ml. In 3.0% of dialyses (n = 83/2724) prolonged fistula compression times were documented. Eight patients (7.34%) had at least one episode of minor bleeding. 4) 85.3% of patients had any adverse event, 9.2% were serious without suspected drug relation; and in 32 patients a drug-relation was suspected. Conclusions Certoparin appears effective and safe for anticoagulation in patients undergoing maintenance hemodialysis.</p
    corecore