2 research outputs found

    Development of light atomic injector for beam emission spectroscopy (BES) diagnostic of Uragan-2M torsatron

    Get PDF
    The improvement of the light atomic injector for beam emission spectroscopy (BES) diagnostic for Uragan-2M was held. The investigation was carried out with the energy of the sodium ion beam was 20…25 keV, the ion current up to 2 mA, and the beam diameter of 15…20 mm with 2 types of neutralizers. Neutralization of the beam was carried out on sodium vapor at an evaporator temperature of up to 300 Β°C. The neutralization efficiency is now near 60…80 % for Na ion current 1.5…2 mA and 20…25 keV beam energy.ΠŸΡ€ΠΎΠ²Π΅Π΄Π΅Π½ΠΎ випробування Ρ–Π½ΠΆΠ΅ΠΊΡ‚ΠΎΡ€Π° Π»Π΅Π³ΠΊΠΈΡ… Π°Ρ‚ΠΎΠΌΡ–Π² для ΠΏΡƒΡ‡ΠΊΠΎΠ²ΠΎ-Смісійної спСктроскопії (ΠŸΠ•Π‘) для діагностики торсатронa Π£Ρ€Π°Π³Π°Π½-2М. ДослідТСння проводилися Π· Π΅Π½Π΅Ρ€Π³Ρ–Ρ”ΡŽ ΠΏΡƒΡ‡ΠΊΠ° Ρ–ΠΎΠ½Ρ–Π² Π½Π°Ρ‚Ρ€Ρ–ΡŽ 20…25 кэВ Ρ–ΠΎΠ½Π½ΠΈΠΌ струмом Π΄ΠΎ 2 мА Ρ‚Π° Π΄Ρ–Π°ΠΌΠ΅Ρ‚Ρ€ΠΎΠΌ ΠΏΡƒΡ‡ΠΊΠ° 15…20 ΠΌΠΌ Π· Π΄Π²ΠΎΠΌΠ° Ρ‚ΠΈΠΏΠ°ΠΌΠΈ Π½Π΅ΠΉΡ‚Ρ€Π°Π»Ρ–Π·Π°Ρ‚ΠΎΡ€Ρ–Π². НСйтралізація ΠΏΡƒΡ‡ΠΊΠ° проводилася Π½Π° ΠΏΠ°Ρ€Π°Ρ… Π½Π°Ρ‚Ρ€Ρ–ΡŽ Π·Π° Ρ‚Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€ΠΎΡŽ Π²ΠΈΠΏΠ°Ρ€Π½ΠΈΠΊΠ° Π΄ΠΎ 300 Β°Π‘. Π•Ρ„Π΅ΠΊΡ‚ΠΈΠ²Π½Ρ–ΡΡ‚ΡŒ Π½Π΅ΠΉΡ‚Ρ€Π°Π»Ρ–Π·Π°Ρ†Ρ–Ρ— Π½Π° Π΄Π°Π½ΠΈΠΉ час ΡΡ‚Π°Π½ΠΎΠ²ΠΈΡ‚ΡŒ 60…80 % для Ρ–ΠΎΠ½Π½ΠΎΠ³ΠΎ струму Π½Π°Ρ‚Ρ€Ρ–ΡŽ 1,5…2 мА Ρ‚Π° Π΅Π½Π΅Ρ€Π³Ρ–Ρ— ΠΏΡƒΡ‡ΠΊΠ° 20…25 ΠΊΠ΅Π’.ΠŸΡ€ΠΎΠ²Π΅Π΄Π΅Π½Ρ‹ испытания ΠΈΠ½ΠΆΠ΅ΠΊΡ‚ΠΎΡ€Π° Π»Π΅Π³ΠΊΠΈΡ… Π°Ρ‚ΠΎΠΌΠΎΠ² для ΠΏΡƒΡ‡ΠΊΠΎΠ²ΠΎ-эмиссионной спСктроскопии (ПЭБ) для диагностики торсатрона Π£Ρ€Π°Π³Π°Π½-2М. ИсслСдования ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΠ»ΠΈΡΡŒ ΠΏΡ€ΠΈ энСргии ΠΏΡƒΡ‡ΠΊΠ° ΠΈΠΎΠ½ΠΎΠ² натрия 20…25 кэВ ΠΈΠΎΠ½Π½Ρ‹ΠΌ Ρ‚ΠΎΠΊΠΎΠΌ Π΄ΠΎ 2 мА ΠΈ Π΄ΠΈΠ°ΠΌΠ΅Ρ‚Ρ€ΠΎΠΌ ΠΏΡƒΡ‡ΠΊΠ° 15…20 ΠΌΠΌ с двумя Ρ‚ΠΈΠΏΠ°ΠΌΠΈ Π½Π΅ΠΉΡ‚Ρ€Π°Π»ΠΈΠ·Π°Ρ‚ΠΎΡ€ΠΎΠ². НСйтрализация ΠΏΡƒΡ‡ΠΊΠ° ΠΏΡ€ΠΎΠ²ΠΎΠ΄ΠΈΠ»Π°ΡΡŒ Π½Π° ΠΏΠ°Ρ€Π°Ρ… натрия ΠΏΡ€ΠΈ Ρ‚Π΅ΠΌΠΏΠ΅Ρ€Π°Ρ‚ΡƒΡ€Π΅ испаритСля Π΄ΠΎ 300 Β°Π‘. Π­Ρ„Ρ„Π΅ΠΊΡ‚ΠΈΠ²Π½ΠΎΡΡ‚ΡŒ Π½Π΅ΠΉΡ‚Ρ€Π°Π»ΠΈΠ·Π°Ρ†ΠΈΠΈ Π² настоящСС врСмя составляСт 60…80 % для ΠΈΠΎΠ½Π½ΠΎΠ³ΠΎ Ρ‚ΠΎΠΊΠ° натрия 1,5…2 мА ΠΈ энСргии ΠΏΡƒΡ‡ΠΊΠ° 20…25 кэВ

    High-intensity cesium ion beams for HIBP diagnostics

    Get PDF
    The goal of the research is to expand the capabilities of the heavy ion beam probing (HIBP) diagnostic. HIBP is a unique diagnostic, capable to measure plasma potential, density and their fluctuations, as well as the poloidal magnetic field fluctuations in the core and edge plasmas. The sensitivity of the diagnostic is determined by the level of the output signal related to the instrumental noise. The level of the probing beam current should be as high as possible, especially for measurements at the periphery with low output signal due to low plasma density, and in the core, where the beam is attenuated due to the high plasma density. Optimization experiments have shown the possibility of ion beam forming in the current range from 40 to 800 ΞΌA.ΠœΠ΅Ρ‚Π° дослідТСння – Ρ€ΠΎΠ·ΡˆΠΈΡ€ΠΈΡ‚ΠΈ моТливості діагностики Π·Π° допомогою зондування ΠΏΠ»Π°Π·ΠΌΠΈ ΠΏΡƒΡ‡ΠΊΠΎΠΌ Π²Π°ΠΆΠΊΠΈΡ… Ρ–ΠΎΠ½Ρ–Π² (Π—ΠŸΠŸΠ’Π†). Π—ΠŸΠŸΠ’Π† – Ρ†Π΅ ΡƒΠ½Ρ–ΠΊΠ°Π»ΡŒΠ½Π° діагностика, Π·Π΄Π°Ρ‚Π½Π° Π²ΠΈΠΌΡ–Ρ€ΡŽΠ²Π°Ρ‚ΠΈ ΠΏΠΎΡ‚Π΅Π½Ρ†Ρ–Π°Π», густину ΠΏΠ»Π°Π·ΠΌΠΈ Ρ– Ρ—Ρ… Ρ„Π»ΡƒΠΊΡ‚ΡƒΠ°Ρ†Ρ–Ρ—, Π° Ρ‚Π°ΠΊΠΎΠΆ Ρ„Π»ΡƒΠΊΡ‚ΡƒΠ°Ρ†Ρ–Ρ— ΠΏΠΎΠ»ΠΎΡ–Π΄Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΠΌΠ°Π³Π½Ρ–Ρ‚Π½ΠΎΠ³ΠΎ поля Π² Ρ†Π΅Π½Ρ‚Ρ€Ρ– Ρ‚Π° ΠΏΠ΅Ρ€ΠΈΡ„Π΅Ρ€Ρ–Ρ— ΠΏΠ»Π°Π·ΠΌΠΈ. Π§ΡƒΡ‚Π»ΠΈΠ²Ρ–ΡΡ‚ΡŒ діагностики Π²ΠΈΠ·Π½Π°Ρ‡Π°Ρ”Ρ‚ΡŒΡΡ Ρ€Ρ–Π²Π½Π΅ΠΌ Π²ΠΈΡ…Ρ–Π΄Π½ΠΎΠ³ΠΎ сигналу, Ρ‰ΠΎΠ΄ΠΎ Ρ–Π½ΡΡ‚Ρ€ΡƒΠΌΠ΅Π½Ρ‚Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΡˆΡƒΠΌΡƒ. Π Ρ–Π²Π΅Π½ΡŒ струму Π·ΠΎΠ½Π΄ΡƒΠ²Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° ΠΏΠΎΠ²ΠΈΠ½Π΅Π½ Π±ΡƒΡ‚ΠΈ якомога Π±Ρ–Π»ΡŒΡˆ високим, особливо для Π²ΠΈΠΌΡ–Ρ€ΡŽΠ²Π°Π½ΡŒ Π½Π° ΠΏΠ΅Ρ€ΠΈΡ„Π΅Ρ€Ρ–Ρ— Π· низьким Π²ΠΈΡ…Ρ–Π΄Π½ΠΈΠΌ сигналом Ρ‡Π΅Ρ€Π΅Π· Π½ΠΈΠ·ΡŒΠΊΡƒ густину ΠΏΠ»Π°Π·ΠΌΠΈ, Π° Ρ‚Π°ΠΊΠΎΠΆ Ρƒ Ρ†Π΅Π½Ρ‚Ρ€Ρ–, Π΄Π΅ ΠΏΡƒΡ‡ΠΎΠΊ ΠΏΠΎΡΠ»Π°Π±Π»ΡŽΡ”Ρ‚ΡŒΡΡ Ρ‡Π΅Ρ€Π΅Π· високу густину ΠΏΠ»Π°Π·ΠΌΠΈ. ЕкспСримСнти Π· ΠΎΠΏΡ‚ΠΈΠΌΡ–Π·Π°Ρ†Ρ–Ρ— ΠΏΠΎΠΊΠ°Π·Π°Π»ΠΈ ΠΌΠΎΠΆΠ»ΠΈΠ²Ρ–ΡΡ‚ΡŒ формування Ρ–ΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° Π² Π΄Ρ–Π°ΠΏΠ°Π·ΠΎΠ½Ρ– струму 40…800 мкА.ЦСль исслСдования – Ρ€Π°ΡΡˆΠΈΡ€ΠΈΡ‚ΡŒ возмоТности диагностики с ΠΏΠΎΠΌΠΎΡ‰ΡŒΡŽ зондирования ΠΏΠ»Π°Π·ΠΌΡ‹ ΠΏΡƒΡ‡ΠΊΠΎΠΌ тяТСлых ΠΈΠΎΠ½ΠΎΠ² (Π—ΠŸΠŸΠ’Π˜). Π—ΠŸΠŸΠ’Π˜ – это ΡƒΠ½ΠΈΠΊΠ°Π»ΡŒΠ½Π°Ρ диагностика, способная ΠΈΠ·ΠΌΠ΅Ρ€ΡΡ‚ΡŒ ΠΏΠΎΡ‚Π΅Π½Ρ†ΠΈΠ°Π», ΠΏΠ»ΠΎΡ‚Π½ΠΎΡΡ‚ΡŒ ΠΏΠ»Π°Π·ΠΌΡ‹ ΠΈ ΠΈΡ… Ρ„Π»ΡƒΠΊΡ‚ΡƒΠ°Ρ†ΠΈΠΈ, Π° Ρ‚Π°ΠΊΠΆΠ΅ Ρ„Π»ΡƒΠΊΡ‚ΡƒΠ°Ρ†ΠΈΠΈ полоидального ΠΌΠ°Π³Π½ΠΈΡ‚Π½ΠΎΠ³ΠΎ поля Π² Ρ†Π΅Π½Ρ‚Ρ€Π΅ ΠΈ ΠΏΠ΅Ρ€ΠΈΡ„Π΅Ρ€ΠΈΠΈ ΠΏΠ»Π°Π·ΠΌΡ‹. Π§ΡƒΠ²ΡΡ‚Π²ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΡŒ диагностики опрСдСляСтся ΡƒΡ€ΠΎΠ²Π½Π΅ΠΌ Π²Ρ‹Ρ…ΠΎΠ΄Π½ΠΎΠ³ΠΎ сигнала ΠΎΡ‚Π½ΠΎΡΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎ ΠΈΠ½ΡΡ‚Ρ€ΡƒΠΌΠ΅Π½Ρ‚Π°Π»ΡŒΠ½ΠΎΠ³ΠΎ ΡˆΡƒΠΌΠ°. Π£Ρ€ΠΎΠ²Π΅Π½ΡŒ Ρ‚ΠΎΠΊΠ° Π·ΠΎΠ½Π΄ΠΈΡ€ΡƒΡŽΡ‰Π΅Π³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° Π΄ΠΎΠ»ΠΆΠ΅Π½ Π±Ρ‹Ρ‚ΡŒ ΠΊΠ°ΠΊ ΠΌΠΎΠΆΠ½ΠΎ Π±ΠΎΠ»Π΅Π΅ высоким, особСнно для ΠΈΠ·ΠΌΠ΅Ρ€Π΅Π½ΠΈΠΉ Π½Π° ΠΏΠ΅Ρ€ΠΈΡ„Π΅Ρ€ΠΈΠΈ с Π½ΠΈΠ·ΠΊΠΈΠΌ Π²Ρ‹Ρ…ΠΎΠ΄Π½Ρ‹ΠΌ сигналом ΠΈΠ·-Π·Π° Π½ΠΈΠ·ΠΊΠΎΠΉ плотности ΠΏΠ»Π°Π·ΠΌΡ‹, Π° Ρ‚Π°ΠΊΠΆΠ΅ Π² Ρ†Π΅Π½Ρ‚Ρ€Π΅, Π³Π΄Π΅ ΠΏΡƒΡ‡ΠΎΠΊ ослабляСтся ΠΈΠ·-Π·Π° высокой плотности ΠΏΠ»Π°Π·ΠΌΡ‹. ЭкспСримСнты ΠΏΠΎ ΠΎΠΏΡ‚ΠΈΠΌΠΈΠ·Π°Ρ†ΠΈΠΈ ΠΏΠΎΠΊΠ°Π·Π°Π»ΠΈ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΡΡ‚ΡŒ формирования ΠΈΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΏΡƒΡ‡ΠΊΠ° Π² Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ Ρ‚ΠΎΠΊΠ° 40…800 мкА
    corecore