18 research outputs found

    Serious adverse side effects after pupillary dilation in preterm infants

    No full text
    International audiencePURPOSE:This study aimed at investigating serious side effects of the pupillary dilation protocol used in Caen University Hospital for the screening of retinopathy of prematurity. This protocol includes one drop of phenylephrine 5% and two drops of tropicamide 0.5% instilled at a 5-minute interval.PATIENTS AND METHODS:This retrospective study included all premature infants with a birth weight less than or equal to 1500 g and/or a gestational age less than or equal to 30 gestational weeks, hospitalized in the neonatal intensive care unit of Caen University Medical Center, having ocular fundus examinations for retinopathy of prematurity screening between 2009 and 2014. The medical records of patients who died or developed necrotizing enterocolitis were reviewed to analyze the imputability of the two eye drops used for pupil dilation.RESULTS:Five-hundred and twelve infants were included, corresponding to 1033 ocular fundus examinations. No case of death could be ascribed to the use of eye drops. Two cases of necrotizing enterocolitis could be ascribed to the use of tropicamide with a doubtful and plausible intrinsic imputability according to French imputability criteria.CONCLUSION:The pupillary dilation protocol used in Caen University Hospital for screening of retinopathy of prematurity might be implicated in two cases of necrotizing enterocolitis with an uncertain imputability of tropicamide 0.5% eye drops. No serious side effect could be ascribed to the use of phenylephrine 5% eye drops in this study

    Evaluation of diabetic retinopathy screening using non-mydriatic fundus camera performed by physicians' assistants in the endocrinology service

    No full text
    International audienceINTRODUCTION:Since 2010, the High Authority for health (HAS) recommends the use of non-mydriatic fundus camera for diabetic retinopathy screening. The purpose of this study is to evaluate the results of screening for diabetic retinopathy using the non-mydriatic retinal camera by a physician's assistant in the endocrinology service.MATERIALS AND METHODS:This is a retrospective study of all diabetic patients hospitalized in the endocrinology department between May 2013 and November 2013. For each endocrinology patient requiring screening, a previously trained physician's assistant performed fundus photos. The ophthalmologist then provided a written interpretation of the photos on a consultant's sheet.RESULTS:Of the 120 patients screened, 40 (33.3%) patients had uninterpretable photos. Among the 80 interpretable photos, 64 (53.4%) patients had no diabetic retinopathy, and 16 (13.3%) had diabetic retinopathy. No patient had diabetic maculopathy.DISCUSSION:Specific quality criteria were established by the HAS for screening for diabetic retinopathy using the non-mydriatic retinal camera in order to ensure sufficient sensitivity and specificity. In our study, the two quality criteria were not achieved: the rates of uninterpretable photos and the total number of photos analyzed in a given period.CONCLUSION:In our center, we discontinued this method of diabetic retinopathy screening due to the high rate of uninterpretable photos. Due to the logistic impossibility of the ophthalmologists taking all the fundus photos, we proposed that the ophthalmic nurses take the photos. They are better trained in the use of the equipment, and can confer directly with an ophthalmologist in questionable cases and to obtain pupil dilation as necessary

    A retrospective, multicenter study on the management of macular holes without residual internal limiting membrane: the refractory macular hole (ReMaHo) study

    No full text
    Purpose: To evaluate the surgical management, outcomes and prognostic factors of full thickness macular holes without residual internal limiting membrane (NO-ILM FTMHs). Methods: We performed a multicenter, retrospective study of 116 NO-ILM FTMHs. Human amniotic membrane (hAM) plug, autologous ILM free flap transplantation (AILMT), and autologous retinal graft transplantation (ART) were performed in 58, 48, and 10 patients, respectively. Data were collected before and up to 12 months after surgery. The primary outcomes were hole closure and final best-corrected visual acuity (BCVA). Results: The final BCVA (0.78 ± 0.51 logMAR) was significantly better than and correlated with the initial BCVA (p < 0.0001 and p = 0.004, respectively). Hole closure was achieved in 92% of eyes. The minimum FTMH diameter was wider and final BCVA was lower in the ART group than in the other groups (p < 0.003 and p < 0.001, respectively). FTMHs with diameter > 680 ÎĽm had a higher closure rate with hAM than with AILMT (p = 0.02). Conclusions: AILMT and hAM were the most frequently performed surgeries with both high closure rate and significant functional improvement. Preoperative BCVA was correlated with final BCVA. The minimum FTMH diameter may guide the treatment choice
    corecore