61 research outputs found

    Исследование характеристик щелевого теплообменника с развитой поверхностью теплообмена

    Get PDF
    Предложена конструкция водяного многоканального щелевого теплообменника, позволяющего отводить мощность до 750 Вт при температуре имитатора теплового потока 60°С, а также пути повышения технологичности изготовления теплообменника

    Radiation dose reduction in pediatric great vessel stent computed tomography using iterative reconstruction: A phantom study

    Get PDF
    Background To study dose reduction using iterative reconstruction (IR) for pediatric great vessel stent computed tomography (CT). Methods Five different great vessel stents were separately placed in a gel-containing plastic holder within an anthropomorphic chest phantom. The stent lumen was filled with diluted contrast gel. CT acquisitions were performed at routine dose, 52% and 81% reduced dose and reconstructed with filtered back projection (FBP) and IR. Objective image quality in terms of noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as subjective image quality were evaluated. Results Noise, SNR and CNR were improved with IR at routine and 52% reduced dose, compared to FBP at routine dose. The lowest dose level resulted in decreased objective image quality with both FBP and IR. Subjective image quality was excellent at all dose levels. Conclusion IR resulted in improved objective image quality at routine dose and 52% reduced dose, while objective image quality deteriorated at 81% reduced dose. Subjective image quality was not affected by dose reduction

    Vascular uptake on 18F-sodium fluoride positron emission tomography:precursor of vascular calcification?

    Get PDF
    Background: Microcalcifications cannot be identified with the present resolution of CT; however, 18F-sodium fluoride (18F-NaF) positron emission tomography (PET) imaging has been proposed for non-invasive identification of microcalcification. The primary objective of this study was to assess whether 18F-NaF activity can assess the presence and predict the progression of CT detectable vascular calcification. Methods and Results: The data of two longitudinal studies in which patients received a 18F-NaF PET-CT at baseline and after 6 months or 1-year follow-up were used. The target to background ratio (TBR) was measured on PET at baseline and CT calcification was quantified in the femoral arteries at baseline and follow-up. 128 patients were included. A higher TBR at baseline was associated with higher calcification mass at baseline and calcification progression (β = 1.006 [1.005-1.007] and β = 1.002 [1.002-1.003] in the studies with 6 months and 1-year follow-up, respectively). In areas without calcification at baseline and where calcification developed at follow-up, the TBR was.11–.13 (P < .001) higher compared to areas where no calcification developed. Conclusion: The activity of 18F-NaF is related to the amount of calcification and calcification progression. In areas where calcification formation occurred, the TBR was slightly but significantly higher

    Normal imaging findings after aortic valve implantation on 18F-Fluorodeoxyglucose positron emission tomography with computed tomography

    Get PDF
    Background: To determine the normal perivalvular 18F-Fluorodeoxyglucose (18F-FDG) uptake on positron emission tomography (PET) with computed tomography (CT) within one year after aortic prosthetic heart valve (PHV) implantation. Methods: Patients with uncomplicated aortic PHV implantation were prospectively included and underwent 18F-FDG PET/CT at either 5 (± 1) weeks (group 1), 12 (± 2) weeks (group 2) or 52 (± 8) weeks (group 3) after implantation. 18F-FDG uptake around the PHV was scored qualitatively (none/low/intermediate/high) and quantitatively by measuring the maximum Standardized Uptake Value (SUVmax) and target to background ratio (SUVratio). Results: In total, 37 patients (group 1: n = 12, group 2: n = 12, group 3: n = 13) (mean age 66 ± 8 years) were prospectively included. Perivalvular 18F-FDG uptake was low (8/12 (67%)) and intermediate (4/12 (33%)) in group 1, low (7/12 (58%)) and intermediate (5/12 (42%)) in group 2, and low (8/13 (62%)) and intermediate (5/13 (38%)) in group 3 (P = 0.91). SUVmax was 4.1 ± 0.7, 4.6 ± 0.9 and 3.8 ± 0.7 (mean ± SD, P = 0.08), and SUVratio was 2.0 [1.9 to 2.2], 2.0 [1.8 to 2.6], and 1.9 [1.7 to 2.0] (median [IQR], P = 0.81) for groups 1, 2, and 3, respectively. Conclusion: Non-infected aortic PHV have similar low to intermediate perivalvular 18F-FDG uptake with similar SUVmax and SUVratio at 5, 12, and 52 weeks after implantation

    Radiation dose reduction for CT assessment of urolithiasis using iterative reconstruction: A prospective intra-individual study

    Get PDF
    Objective: To assess the performance of hybrid (HIR) and model-based iterative reconstruction (MIR) in patients with urolithiasis at reduced-dose computed tomography (CT). Methods: Twenty patients scheduled for unenhanced abdominal CT for follow-up of urolithiasis were prospectively included. Routine dose acquisition was followed by three low-dose acquisitions at 40%, 60% and 80% reduced doses. All images were reconstructed with filtered back projection (FBP), HIR and MIR. Urolithiasis detection rates, gall bladder, appendix and rectosigmoid evaluation and overall subjective image quality were evaluated by two observers. Results: 74 stones were present in 17 patients. Half the stones were not detected on FBP at the lowest dose level, but this improved with MIR to a sensitivity of 100%. HIR resulted in a slight decrease in sensitivity at the lowest dose to 72%, but outperformed FBP. Evaluation of other structures with HIR at 40% and with MIR at 60% dose reductions was comparable to FBP at routine dose, but 80% dose reduction resulted in non-evaluable images. Conclusions: CT radiation dose for urolithiasis detection can be safely reduced by 40 (HIR)–60 (MIR) % without affecting assessment of urolithiasis, possible extra-urinary tract pathology or overall image quality. Key Points: • Iterative reconstruction can be used to substantially lower the radiation dose. • This allows for radiation reduction without affecting sensitivity of stone detection. • Possible extra-urinary tract pathology evaluation is feasible at 40–60% reduced dose

    Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation

    Get PDF
    Background: Stents are commonly used to treat aortic coarctation. The objective of this study was to evaluate the post-implantation computed tomography (CT) image quality of different stent types used to treat aortic coarctation. Methods: Adult and paediatric patients with stent-treated aortic coarctation who underwent contrast-enhanced CT were retrospectively included from three tertiary care centres. CT scans were subjectively scored for image quality using a 4-point scale (1 = unacceptable; 2 = poor; 3 = good; 4 = excellent). Furthermore, the amount of stent-induced blooming artefacts was measured as the percentage of the difference between outer and inner stent diameters over the outer stent diameter. Results: A total of 35 children and 34 adults implanted with 71 stents of six different types were included. The most commonly used stent type was the Cheatham Platinum stent (52 stents, 73%). The subjective image quality of the Cheatham Platinum stents was moderate with a score of 2.0±0.8 (mean ± standard deviation) in children and 2.3±0.6 in adults. The image quality in patients with Formula stents was 2.3±1.2. The Cheatham Platinum stents induced 34–48% blooming, the Formula stents 44–55%. The image quality in patients with the less commonly used Atrium Advanta V12, IntraStent, AndraStent and Palmaz stents was scored 3 (good) to 4 (excellent) with less blooming. The electrocardiographic gating and tube voltage (kVp) did not affect image quality. Conclusions: There is a substantial variation in CT image quality a

    New clinical prediction model for early recognition of sepsis in adult primary care patients:a prospective diagnostic cohort study of development and external validation

    Get PDF
    Background Recognising patients who need immediate hospital treatment for sepsis while simultaneously limiting unnecessary referrals is challenging for GPs.Aim To develop and validate a sepsis prediction model for adult patients in primary care.Design and setting This was a prospective cohort study in four out-of-hours primary care services in the Netherlands, conducted between June 2018 and March 2020.Method Adult patients who were acutely ill and received home visits were included. A total of nine clinical variables were selected as candidate predictors, next to the biomarkers C-reactive protein, procalcitonin, and lactate. The primary endpoint was sepsis within 72 hours of inclusion, as established by an expert panel. Multivariable logistic regression with backwards selection was used to design an optimal model with continuous clinical variables. The added value of the biomarkers was evaluated. Subsequently, a simple model using single cut-off points of continuous variables was developed and externally validated in two emergency department populations.Results A total of 357 patients were included with a median age of 80 years (interquartile range 71–86), of which 151 (42%) were diagnosed with sepsis. A model based on a simple count of one point for each of six variables (aged &gt;65 years; temperature &gt;38°C; systolic blood pressure ≤110 mmHg; heart rate &gt;110/min; saturation ≤95%; and altered mental status) had good discrimination and calibration (C-statistic of 0.80 [95% confidence interval = 0.75 to 0.84]; Brier score 0.175). Biomarkers did not improve the performance of the model and were therefore not included. The model was robust during external validation.Conclusion Based on this study’s GP out-of-hours population, a simple model can accurately predict sepsis in acutely ill adult patients using readily available clinical parameters

    Aortic homograft replacement in a patient with a porcelain aorta : A case report

    No full text
    Patients with a severely calcified (porcelain) aorta are often unsuitable candidates for cardiac surgery because of the high risk of neuroembolic complications from loose calcified particles.We describe a surgical technique in a patient with a porcelain aorta undergoing an aortic homograft replacement for infective endocarditis that used an oscillating saw and a surgical hand drill for suturing the calcified plates
    corecore