6,102 research outputs found

    GEOS-3 C-Band radar investigations

    Get PDF
    The absolute accuracy of instrumentation radar systems, refined methods of calibrating these systems, and the techniques employed in processing the associated data. A world-wide network of C-Band instrumentation radars augmented by lasers and other tracking instrumentation systems were used. The NASA WFC AN/FPQ-6 instrumentation radar and the AN/FPS-16 instrumentation radar also located at NASA WFC were the primary instruments used in the accuracy and calibration evaluations. The results achieved at WFC were then disseminated to other Ranges where they were verified, augmented and used as part of routine operations

    Vibration simulator studies for the development of passenger ride comfort criteria

    Get PDF
    A test program to determine the total discomfort associated with vehicle vibration is described. The program utilizes a three-degree-of-freedom vibration simulator to determine the effects of multifrequency and multiaxis vibration inputs. The approach to multifrequency vibration includes a separate consideration of the discomfort associated with each frequency component or band of the total spectrum and a subsequent empirical weighting of the discomfort components of these frequency bands when in various random combinations. The results are in the form of equal discomfort curves that specify the discomfort associated with discrete frequencies between 1 and 30 Hz and different acceleration levels. These results provide detailed information of the human discomfort response to increases in acceleration level for each frequency investigated. More importantly, the results provide a method for adding the discomfort associated with separate frequencies to give a total typification of the discomfort of a random spectrum of vibration

    Experimental studies for determining human discomfort response to vertical sinusoidal vibration

    Get PDF
    A study was conducted to investigate several problems related to methodology and design of experiments to obtain human comfort response to vertical sinusoidal vibration. Specifically, the studies were directed to the determination of (1) the adequacy of frequency averaging of vibration data to obtain discomfort predictors, (2) the effect of practice on subject ratings, (3) the effect of the demographic factors of age, sex, and weight, and (4) the relative importance of seat and floor vibrations in the determination of measurement and criteria specification location. Results indicate that accurate prediction of discomfort requires knowledge of both the acceleration level and frequency content of the vibration stimuli. More importantly, the prediction of discomfort was shown to be equally good based upon either floor accelerations or seat accelerations. Furthermore, it was demonstrated that the discomfort levels in different seats resulting from similar vibratory imputs were equal. Therefore, it was recommended that criteria specifications and acceleration measurements be made at the floor location. The results also indicated that practice did not systematically influence discomfort responses nor did the demographic factors of age, weight, and sex contribute to the discomfort response variation

    A proposed group management scheme for XTP multicast

    Get PDF
    The purpose of a group management scheme is to enable its associated transfer layer protocol to be responsive to user determined reliability requirements for multicasting. Group management (GM) must assist the client process in coordinating multicast group membership, allow the user to express the subset of the multicast group that a particular multicast distribution must reach in order to be successful (reliable), and provide the transfer layer protocol with the group membership information necessary to guarantee delivery to this subset. GM provides services and mechanisms that respond to the need of the client process or process level management protocols to coordinate, modify, and determine attributes of the multicast group, especially membership. XTP GM provides a link between process groups and their multicast groups by maintaining a group membership database that identifies members in a name space understood by the underlying transfer layer protocol. Other attributes of the multicast group useful to both the client process and the data transfer protocol may be stored in the database. Examples include the relative dispersion, most recent update, and default delivery parameters of a group

    C-band radar pulse Doppler error: Its discovery, modeling, and elimination

    Get PDF
    The discovery of a C Band radar pulse Doppler error is discussed and use of the GEOS 3 satellite's coherent transponder to isolate the error source is described. An analysis of the pulse Doppler tracking loop is presented and a mathematical model for the error was developed. Error correction techniques were developed and are described including implementation details

    Issues in designing transport layer multicast facilities

    Get PDF
    Multicasting denotes a facility in a communications system for providing efficient delivery from a message's source to some well-defined set of locations using a single logical address. While modem network hardware supports multidestination delivery, first generation Transport Layer protocols (e.g., the DoD Transmission Control Protocol (TCP) (15) and ISO TP-4 (41)) did not anticipate the changes over the past decade in underlying network hardware, transmission speeds, and communication patterns that have enabled and driven the interest in reliable multicast. Much recent research has focused on integrating the underlying hardware multicast capability with the reliable services of Transport Layer protocols. Here, we explore the communication issues surrounding the design of such a reliable multicast mechanism. Approaches and solutions from the literature are discussed, and four experimental Transport Layer protocols that incorporate reliable multicast are examined

    A reliable multicast for XTP

    Get PDF
    Multicast services needed for current distributed applications on LAN's fall generally into one of three categories: datagram, semi-reliable, and reliable. Transport layer multicast datagrams represent unreliable service in which the transmitting context 'fires and forgets'. XTP executes these semantics when the MULTI and NOERR mode bits are both set. Distributing sensor data and other applications in which application-level error recovery strategies are appropriate benefit from the efficiency in multidestination delivery offered by datagram service. Semi-reliable service refers to multicasting in which the control algorithms of the transport layer--error, flow, and rate control--are used in transferring the multicast distribution to the set of receiving contexts, the multicast group. The multicast defined in XTP provides semi-reliable service. Since, under a semi-reliable service, joining a multicast group means listening on the group address and entails no coordination with other members, a semi-reliable facility can be used for communication between a client and a server group as well as true peer-to-peer group communication. Resource location in a LAN is an important application domain. The term 'semi-reliable' refers to the fact that group membership changes go undetected. No attempt is made to assess the current membership of the group at any time--before, during, or after--the data transfer

    Using silicon diodes for detecting the liquid-vapor interface in hydrogen

    Get PDF
    Tests were performed using commercially available silicon diode temperature sensors to detect the location of the liquid-vapor interface in hydrogen during ground test programs. Results show that by increasing the current into the sensor, silicon diodes can be used as liquid level point sensors. After cycling the sensors from liquid to vapor several times, it was found that with a 30 mA (milliamps) input current, the sensors respond within 2 seconds by measuring a large voltage difference when transitioning from liquid to vapor across the interface. Nearly instantaneous response resulted during a transition form vapor to liquid. Detailed here are test procedures, experimental results, and guidelines for applying this information to other test facilities

    Techniques for improving the accuracy of cyrogenic temperature measurement in ground test programs

    Get PDF
    The performance of a sensor is often evaluated by determining to what degree of accuracy a measurement can be made using this sensor. The absolute accuracy of a sensor is an important parameter considered when choosing the type of sensor to use in research experiments. Tests were performed to improve the accuracy of cryogenic temperature measurements by calibration of the temperature sensors when installed in their experimental operating environment. The calibration information was then used to correct for temperature sensor measurement errors by adjusting the data acquisition system software. This paper describes a method to improve the accuracy of cryogenic temperature measurements using corrections in the data acquisition system software such that the uncertainty of an individual temperature sensor is improved from plus or minus 0.90 deg R to plus or minus 0.20 deg R over a specified range

    Sources, control, and effects of noise from aircraft propellers and rotors

    Get PDF
    Source noise predictions are compared with measurements for conventional low-speed propellers, for new high speed propellers (propfans), and for a helicopter. Results from a light aircraft demonstration program are described, indicating that about 5-dB reduction of flyover noise can be obtained without significant performance penalty. Sidewall design studies are described for interior noise control in light general aviation aircraft and in large transports using propfan propulsion. The weight of the added acoustic treatment is estimated and tradeoffs between weight and noise reduction are discussed. A laboratory study of passenger response to combined broadband and tonal propeller like noise is described. Subject discomfort ratings of combined tone broadband noises are compared with ratings of broadband (boundary layer) noise alone, and the relative importance of the propeller tones is examined
    corecore