47 research outputs found

    Aneurysm Coil Embolization Using a 1.5-Fr Distal Outer Diameter Microcatheter

    Get PDF
    The current assortment of microcatheters widely used for aneurysm coil embolization may not be well suited for several anatomic variants, including excessive vascular tortuosity and small aneurysms less than 3 mm. Longer microcatheters designed with a smaller caliber that can accommodate and deliver coils may be of use in these situations. This case series and literature review illustrates the advantages and limitations of the Marathon microcatheter (Covidien, Irvine, CA, USA) when used for coil embolization of cerebral aneurysms. Despite some technical compromises including the distal marker, length, and the risk of buckling, the Marathon microcatheter was able to adequately deliver coils to achieve satisfactory occlusion of cerebral aneurysms. We found unique advantages with regards to length and smaller distal outer diameter (OD). These results may serve as a guide for the further development of a microcatheter used for coil embolization that has the features of a smaller distal OD and longer length

    Mobile Real-time Tracking of Acute Stroke Patients and Instant, Secure Inter-team Communication - the Join App

    Get PDF
    PurposeThe primary correlate to survival and preservation of neurologic function in patients suffering from an acute ischemic stroke is time from symptom onset to initiation of therapy and reperfusion. Communication and coordination among members of the stroke team are essential to maximizing efficiency and subsequently early reperfusion. In this work, we aim to describe our preliminary experience using the Join mobile application as a means to improve interdisciplinary team communication and efficiency.Materials and MethodsWe describe our pilot experience with the initiation of the Join mobile application between July 2015 and July 2016. With this application, a mobile beacon is transported with the patient on the ambulance. Transportation milestone timestamps and geographic coordinates are transmitted to the treating facility and instantly communicated to all treatment team members. The transport team / patient can be tracked en route to the treating facility.ResultsDuring our pilot study, 62 patients were triaged and managed using the Join application. Automated time-stamping of critical events, geographic tracking of patient transport and summary documents were obtained for all patients. Treatment team members had an overall favorable impression of the Join application and recommended its continued use.ConclusionThe Join application is one of several components of a multi-institutional, interdisciplinary effort to improve the treatment of patients with acute ischemic stroke. The ability of the treatment team to track patient transport and communicate with the transporting team may improve reperfusion time and, therefore, improve neurologic outcomes

    Glucose modifies the effect of endovascular thrombectomy in patients with acute stroke: a pooled-data meta-analysis

    Get PDF
    Background and Purpose: Hyperglycemia is a negative prognostic factor following acute ischemic stroke but is not known whether glucose is associated with the effects of endovascular thrombectomy in patients with large vessel stroke. In a pooled-data meta-analysis, we analyzed whether serum glucose is a treatment modifier of the efficacy of endovascular thrombectomy in acute stroke. Methods: Seven randomized trials compared endovascular thrombectomy with standard care between 2010 and 2017 (HERMES Collaboration). 1764 patients with large vessel stroke were allocated to endovascular thrombectomy (n=871) or standard care (n=893). Measurements included blood glucose on admission and functional outcome [modified Rankin Scale (mRS) range: 0-6; lower scores indicating less disability] at 3 months. The primary analysis evaluated whether glucose modified the effect of EVT over standard care on functional outcome, using ordinal logistic regression to test the interaction between treatment and glucose level. Results: Median (IQR) serum glucose on admission was 120 (104-140) mg/dl [6.6mmol/l (5.7-7.7) mmol/l]. Endovascular thrombectomy (EVT) was better than standard care in the overall pooled-data analysis [common odds ratio (acOR), 2.00 (95% CI 1.69–2.38); however, lower glucose levels were associated with greater effects of EVT over standard care. The interaction was nonlinear such that significant interactions were found in subgroups of patients split at glucose < or > 90mg/dl (5.0mmol/l) [(p=0.019 for interaction, acOR 3.81 (95% CI 1.73–8.41) for patients < 90 mg/dl vs 1.83 (95% CI 1.53–2.19) for patients > 90 mg/dl], and glucose < or > 100mg/dl (5.5mmol/l) [(p=0.004 for interaction, acOR 3.17 (95% CI 2.04–4.93) vs acOR 1.72 (95% CI 1.42–2.08)], but not between subgroups above these levels of glucose. Conclusions: Endovascular thrombectomy improved stroke outcomes compared to standard treatment regardless of glucose levels but the treatment effects were larger at lower glucose levels, with significant interaction effects persisting up to 90 to 100mg/dl (5.0-5.5mmol/l). Whether tight control of glucose improves the efficacy of endovascular thrombectomy following large vessel stroke warrants appropriate testing

    Neuro-endovascular Embolic Agent for Treatment of a Renal Arteriovenous Fistula

    No full text
    Renal arteriovenous fistula is a known complication following a renal biopsy, and may require catheter based embolization. Distal location of these fistulas in the renal parenchyma in many a case may necessitate non-traditional embolic materials. Liquid embolic agents that allow a controlled delivery may be suitable in this situation, as demonstrated in this case report

    Transvenous arteriovenous malformation embolization

    No full text
    Transvenous embolization of arteriovenous malformations has emerged as a safe and effective intervention. In carefully selected patients the transvenous approach has shown efficacy similar to that of conventional transarterial routes. The optimal lesions amenable to the transvenous approach have not been robustly delineated; however, the approach is reserved for small, deep seeded, single venous drainage lesions with poorly amenable arterial vascular supply. In this video we demonstrate a case of transvernous Onyx embolization of a Spetzler-Martin grade 3 (SM3) left hemispheric, ruptured arteriovenous malformation. The patient underwent successful, single session, complete embolization of the arteriovenous malformation through a venous route without further complications or repeat treatment

    Optical coherence tomography for elucidation of flow-diversion phenomena: The concept of endothelized mural thrombus behind reversible in-stent stenosis in flow-diverters

    No full text
    PURPOSE: Flow-diverters have revolutionized the endovascular treatment of intracranial aneurysms, offering a durable solution to aneurysms with high recurrence rates after conventional stent-assisted coiling. Events that occur after treatment with flow-diversion, such as in-stent stenosis (ISS) are not well understood and require further assessment. After assessing an animal model with Optical Coherence Tomography (OCT), we propose a concept that could explain the mechanism causing reversible ISS after treatment of intracranial aneurysms with flow-diverters. METHODS: Six Pipeline Flex embolization devices (PED-Flex), six PED with Shield technology (PED-Shield), and four Solitaire AB devices were implanted in the carotid arteries (two stents per vessel) of four pigs. Intravascular optical coherence tomography (OCT) and digital subtraction angiography (DSA) images obtained on day 21 were compared to histological specimens. RESULTS: A case of ISS in a PED-Flex device was assessed with OCT imaging. Neointima with asymmetrical topography completely covering the PED struts was observed. Histological preparations of the stenotic area demonstrated thrombus on the surface of device struts, covered by neointima. CONCLUSION: This study provides a plausible concept for reversible ISS in flow-diverters. Based on an observation of a previous experiment, we propose that similar cases of ISS are related to thrombus presence underneath endothelization, but further experiments focused on this phenomenon are needed. Optical Coherence Tomography will be useful tool when available for clinical use
    corecore