15 research outputs found
Blowing off steam—Identifying bowel perforation after routine colonoscopy
Abstract Colonoscopy is an effective procedure for colorectal cancer (CRC) screening. Perforation is a rare yet the most severe complication, identified by landmarks—double dolphin, triangle, or double‐wall sign signifying air and intracolonic contents leaking into the peritoneal space. Prompt recognition and surgical intervention are imperative to avoid high mortality
The diagnostic performance of probe-based confocal laser endomicroscopy in the detection of gastric cancer: a systematic review and meta-analysis
Background: Gastric cancer (GC) represents a significant global health burden with high morbidity and mortality, especially when diagnosed at advanced stages. Therefore, early detection of GC is critical. Probe-based confocal laser endomicroscopy (pCLE) is a new evolving technology that uses real-time, high-resolution imaging to inspect the mucosa at the cellular and microvascular level, using a confocal probe. Widespread studies using pCLE are limited at the current time. We aimed to investigate the diagnostic efficacy of this modality for the detection of GC. Methods: Multiple databases were searched from inception until November 2021. The diagnostic performance of pCLE was assessed by calculating its sensitivity, specificity and accuracy for the detection of GC, using pooled proportions and 95% confidence intervals (CI) with a random-effects model. Heterogeneity was assessed using I. Results: Seven studies were included, with a total of 567 patients (mean age 61.7 years, 364 males). Pooled performance metrics of pCLE included a sensitivity of 87.9% (95%CI 81.4-92.4; P\u3c0.001; I=0%), specificity 96.5% (95%CI 91.5-98.6; P\u3c0.001; I=51.84%), and an accuracy of 94.7% (95%CI 89.5-97.4; P\u3c0.001; I=65.44%). Conclusions: pCLE is a highly effective diagnostic modality for detecting GC. Larger, randomized controlled studies are needed to determine its role in daily practice compared to conventional endoscopic practices
Angiotensin-Converting Enzyme (ACE) Inhibitors and Pancreatitis: A Potential Dose-dependent Relationship
Acute pancreatitis (AP) remains one of the most common causes of emergency department visits in the USA. The literature supports an association between angiotensin-converting enzyme inhibitors (ACEi), mainly at steady-state doses, and AP[1]. We present a case of recurrent AP and pseudocyst formation following multiple ACEi dose adjustments after a steady-state period lasting for over a decade. Previous reports have rarely described ACEi-induced pancreatitis and pseudocyst development. ACEi can cause significant ductal obstruction[2]and fluid retention due to its angioedema effects. Consequently, it may trigger AP complicated by pseudocyst formation. Therefore, ACEi administration must be considered in the appropriate clinical context
Effectiveness and safety of stag beetle knife (SB knife) in management of Zenker's diverticulum: a systematic review and meta-analysis
: Stag Beetle Knife (SB Knife) is increasingly being utilized for Zenker's Diverticulectomy (ZD). Our study assessed the effectiveness and safety of the SB Knife for the management of ZD. Ovid EBM reviews, Ovid Embase, Ovid Medline, ClinicalTrials.gov, Scopus, and Web of Science were searched to identify studies that utilized SB knife for ZD. Pooled proportions (PP) were calculated using the random-effects model. Heterogeneity was evaluated using I2 statistics. A total of 7 studies with 268 patients were included in the final analysis. Dysphagia and regurgitation were the most common clinical symptoms. The mean size of the ZD was 2.8 ± 0.7 cm and 28 (of 148) patients had undergone previous treatments. The PP of technical success was 98% (95% CI: 92.3-99.5; I20) with a mean procedure duration of 26.2 ± 8.3 minutes. The PP of clinical response at first follow-up and relapse after index procedure was 87.9% (95% CI: 81.6-92.3; I219) and 13.5% (95% CI: 9.6-18.6; I22), respectively. At final follow-up, the PP of clinical remission was 96.2% (95% CI: 91-98.4; I230.6) while the PP of procedure failure was 3.6% (95% CI: 1.6-8.1; I20). No severe adverse events (AEs) were noted while using the SB Knife. However, the PP of intraprocedural and postprocedural AEs was 13.2% (95% CI: 9.6-17.8; I20) and 9.3% (95% CI: 5.7-14.9; I2 < 20.9), respectively. SB Knife is highly safe and effective for Zenker's Diverticulectomy with a failure rate of only 3.6%
Adverse Events of Endoscopic Clip Placement: A MAUDE Database Analysis
Background: Clips are endoscopic mechanical devices with tensile and closure strength that can approximate tissue and provide hemostasis through a tamponade effect. Clips are ubiquitously used in endoscopic practice, and numerous studies have validated the clinical efficacy of clips, with recent guidelines recommending them as a first-line intervention for recurrent and persistent nonvariceal gastrointestinal bleeding. However, the safety profile for these devices has yet to be delineated, thus, we aim to investigate this feature by examining the adverse events reported to the Food and Drug Administration. Methods: Postmarketing surveillance data from the Food and Drug Administration Manufacturer And User Facility Device Experience database were analyzed from January 2012 to January 2021. The Manufacturer And User Facility Device Experience database is a reporting software and does not independently verify the details of complications. Results: Two thousand five hundred forty reports were issued, of which 287 were patient adverse events and 2766 were device problems. Activation, separation, and positioning issues were most common. No consequences or clinically significant impact on patients were seen in 1968 reports. Foreign bodies were seen in 97 cases, hemorrhage in 57 cases, tissue damage in 42 cases, embedded clips in tissues/plaques in 16 cases, perforation in 15 cases, lacerations in 6 cases, and infection in 3 cases. Conclusions: While the most commonly reported device problems involved activation, separation, and positioning, most patients were clinically unaffected. Moreover, perforation and infection were exceedingly rare, further highlighting the safety profile of endoscopic clips
Snare tip soft coagulation (STSC) after endoscopic mucosal resection (EMR) of large (> 20 mm) non pedunculated colorectal polyps: a systematic review and meta-analysis
Background and study aims Endoscopic mucosal resection (EMR) of laterally spreading tumors (LSTs) > 20 mm in size can be challenging. Piecemeal EMR of these lesions results in high rates of adenoma recurrence at first surveillance colonoscopy (SC1). Snare tip soft coagulation (STSC) of post resection margins is a safe and effective technique to prevent adenoma recurrence. We conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of this technique.Patients and methods Multiple databases were searched through April 2021 for studies that reported on outcomes of post EMR STSC for LSTs > 20 mm in size. Meta-analysis was performed to determine pooled odds of adenoma recurrence as well as pooled proportion of adverse events including intraprocedural and delayed bleeding as well as intraprocedural perforation events.Results Six studies including two randomized controlled trials (RCT) and four cohort studies with 2122 patients were included in the final analysis. Overall pooled odds of adenoma recurrence at SC1 with post EMR STSC compared to no STSC was 0.27 (95 % 0.18-0.42; I-2 = 0 %), P < 0.001. Pooled rate of adenoma recurrence at SC1 in post EMR STSC cohort was 6 %. Rates of intraprocedural bleeding, delayed bleeding and intraprocedural perforation were 10.3 %, 6.5 % and 2 % respectively.Conclusions Our results show that thermal ablation of resection margins with STSC in LSTs > 20 mm is a safe and effective technique in reducing the incidence of adenoma recurrence
Efficacy & safety of EUS-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE) in Roux-en-Y gastric bypass anatomy: a systematic review & meta-analysis
Background: In patients with Roux-en-Y gastric bypass (RYGB) anatomy, laparoscopic endoscopic retrograde cholangiopancreatography (LA-ERCP) and enteroscopy-assisted ERCP (E-ERCP) have been utilized to achieve pancreaticobiliary access. Endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE) has recently emerged as an alternate and efficient approach. As data regarding EDGE continues to evolve, concerns about safety and efficacy remain, limiting wide adoptability. We performed a systematic review and meta-analysis to assess the safety and efficacy of EDGE and compare it to the current standard of care. Methods: A comprehensive search of major databases (inception to Nov 2022) identified published studies on EDGE. A random-effects model was used to calculate the pooled rates and heterogeneity (I2). Risk ratio (RR) and standardized difference in means (SMD) were utilized for head-to-head comparison analysis between EDGE vs. LA-ERCP and EDGE vs. E-ERCP. Primary outcomes assessed pooled EDGE safety (adverse events) and efficacy (technical/clinical success). Secondary outcomes assessed efficacy and safety profiles via a comparative analysis of EDGE vs. LA-ERCP and EDGE vs. E-ERCP. Results: A total of 16 studies (470 patients) were included. EDGE pooled technical success (TS) rate was 96% (95% CI 92-97.6, I2 = 0), and clinical success was 91% (85-95, I2 = 0). Pooled rate of all adverse events with EDGE was 17% (14-24.6, I2 = 32%). On sub-group analysis, these included failure of fistula closure 17% (10-25.5, I2 = 48%), stent migration 7% (4-12, I2 = 51%), bleeding 5% (3.2-7.9, I2 = 0), post-EDGE weight gain 4% (2-9, I2 = 0), perforation 4% (2.1-5.8, I2 = 0), and post-ERCP pancreatitis 2% (1-5, I2 = 0). EDGE TS was comparable to LA-ERCP (97% vs. 98%; RR, 1.00; CI, 0.85-1.17, p = 0.95) and E-ERCP (100% vs. 66%; RR, 1.26; CI, 0.99-1.6, p = 0.06). No statistical difference was noted in adverse events between EDGE and LA-ERCP (13% vs. 17.6%; RR, 0.61; CI, 0.28-1.35, p = 0.52) and E-ERCP (9.6% vs. 16%; RR, 0.61; CI, 0.28-1.35, p = 0.22). EDGE procedure time and hospital stay were shorter than LA-ERCP and E-ERCP (p < 0.001). Conclusion: Our analysis shows that EDGE is safe and efficacious to the current standard of care. Further head-to-head comparative trials are needed to validate our findings
Early (<4 Weeks) Versus Standard (≥ 4 Weeks) Endoscopic Drainage of Pancreatic Walled-Off Fluid Collections: A Systematic Review and Meta-analysis
Previous studies have demonstrated that the ideal time for drainage of walled off pancreatic fluid collections is 4-6 weeks after its development. However, some pancreatic collections, notably infected pancreatic fluid collections require earlier drainage. Nevertheless, the optimal timing of the first intervention is unclear, and consensus data are sparse. The aim of this study was to evaluate clinical efficacy and safety of endoscopic ultrasound (EUS) - guided drainage of pancreatic fluid collections < than 4 weeks after its development compared to ≥4 weeks after its development