519 research outputs found

    The infrared imaging spectrograph (IRIS) for TMT: spectrograph design

    Get PDF
    The Infra-Red Imaging Spectrograph (IRIS) is one of the three first light instruments for the Thirty Meter Telescope (TMT) and is the only one to directly sample the diffraction limit. The instrument consists of a parallel imager and off-axis Integral Field Spectrograph (IFS) for optimum use of the near infrared (0.84um-2.4um) Adaptive Optics corrected focal surface. We present an overview of the IRIS spectrograph that is designed to probe a range of scientific targets from the dynamics and morphology of high-z galaxies to studying the atmospheres and surfaces of solar system objects, the latter requiring a narrow field and high Strehl performance. The IRIS spectrograph is a hybrid system consisting of two state of the art IFS technologies providing four plate scales (4mas, 9mas, 25mas, 50mas spaxel sizes). We present the design of the unique hybrid system that combines the power of a lenslet spectrograph and image slicer spectrograph in a configuration where major hardware is shared. The result is a powerful yet economical solution to what would otherwise require two separate 30m-class instruments.Comment: 15 pages, 11 figure

    The Optimal Gravitational Lens Telescope

    Get PDF
    Given an observed gravitational lens mirage produced by a foreground deflector (cf. galaxy, quasar, cluster,...), it is possible via numerical lens inversion to retrieve the real source image, taking full advantage of the magnifying power of the cosmic lens. This has been achieved in the past for several remarkable gravitational lens systems. Instead, we propose here to invert an observed multiply imaged source directly at the telescope using an ad-hoc optical instrument which is described in the present paper. Compared to the previous method, this should allow one to detect fainter source features as well as to use such an optimal gravitational lens telescope to explore even fainter objects located behind and near the lens. Laboratory and numerical experiments illustrate this new approach

    Modulating between 2e<sup>-</sup> and 4e<sup>-</sup> pathway in the oxygen reduction reaction with laser-synthesized iron oxide-grafted nitrogen-doped carbon

    Get PDF
    In this study, we demonstrate the tuning of the oxygen reduction reaction (ORR) by iron/iron oxide nanoparticle grafted laser-patterned nitrogen-doped carbon (LP-NC) electrodes. Depending on the preparation route, i.e. addition of a molecular Fe(NO3)2 precursor before (route 1) or after pre-carbonization (route 2) of the citric acid / urea precursors, either the 4e- or the 2e- pathway in the ORR is facilitated leading to either H2O or H2O2 as a reaction product, respectively. The kinetic reaction conditions afford mixed valence metal oxide nanoparticles embedded in LP-NC in the form of either Fe2O3/Fe or Fe2O3/FeO/Fe, respectively, facilitated by an in situ carbothermal reduction during the laser-induced carbonization. In HR(S)TEM analysis we found evidence for the occurrence of Fe2O3 in the η- or α- phase, depending on the preparation route. Reciprocally, the graphitization is also affected by the preparation route leading to either homogeneous graphitization or locally a graphitized shell structures around the nanoparticles. In the 4e- mediated ORR facilitated by η-Fe2O3/Fe@LP-NC onset potentials as low as 0.70 V (vs. RHE) with a H2O2 production efficiency 4% and 10 % in alkaline and neutral electrolyte, respectively, were determined. On the other hand, α-Fe2O3/FeO/Fe@LP-NC present onset potentials for the 2e- mediated ORR is as low as 0.77 with a H2O2 production efficiency of nearly 80%

    A diamond AGPM coronagraph for VISIR

    Get PDF
    In recent years, phase mask coronagraphy has become increasingly efficient in imaging the close environment of stars, enabling the search for exoplanets and circumstellar disks. Coronagraphs are ideally suited instruments, characterized by high dynamic range imaging capabilities, while preserving a small inner working angle. The AGPM (Annular Groove Phase Mask, Mawet et al. 2005) consists of a vector vortex induced by a rotationally symmetric subwavelength grating. This technique constitutes an almost unique solution to the achromatization at longer wavelengths (mid-infrared). For this reason, we have specially conceived a mid-infrared AGPM coronagraph for the forthcoming upgrade of VISIR, the mid-IR imager and spectrograph on the VLT at ESO (Paranal), in collaboration with members of the VISIR consortium. The implementation phase of the VISIR Upgrade Project is foreseen for May-August 2012, and the AGPM installed will cover the 11-13.2 μm spectral range. In this paper, we present the entire fabrication process of our AGPM imprinted on a diamond substrate. Diamond is an ideal material for mid-infrared wavelengths owing to its high transparency, small dispersion, extremely low thermal expansion and outstanding mechanical and chemical properties. The design process has been performed with an algorithm based on the rigorous coupled wave analysis (RCWA), and the micro-fabrication has been carried out using nano-imprint lithography and reactive ion etching. A precise grating profile metrology has also been conducted using cleaving techniques. Finally, we show the deposit of fiducials (i.e. centering marks) with Aerosol Jet Printing (AJP). We conclude with the ultimate coronagraph expected performances

    A Mach-Zehnder interferometer based on orbital angular momentum for improved vortex coronagraph efficiency

    Get PDF
    The Annular Groove Phase Mask (AGPM) is a vectorial vortex phase mask. It acts as a half-wave plate with a radial fast axis orientation operating in the mid infrared domain. When placed at the focus of a telescope element provides a continuous helical phase ramp for an on axis sources, which creates the orbital angular momentum. Thanks to that phase, the intensity of the central source is canceled by a down-stream pupil stop, while the off axis sources are not affected. However due to experimental conditions the nulling is hardly perfect. To improve the null, a Mach-Zehnder interferometer containing Dove prisms differently oriented can be proposed to sort out light based on its orbital angular momentum (OAM). Thanks to the differential rotation of the beam, a π phase shift is achieved for the on axis light affected by a non zero OAM. Therefore the contrast between the star and its faint companion is enhanced. Nevertheless, due the Dove prisms birefringence, the performance of the interferometer is relatively poor. To solve this problem, we propose to add a birefringent wave-plate in each arm to compensate this birefringence. In this paper, we will develop the mathematical model of the wave front using the Jones formalism. The performance of the interferometer is at first computed for the simple version without the birefringent plate. Then the effect of the birefringent plate is be mathematically described and the performance is re-computed

    L'-band AGPM vector vortex coronagraph's first light on LBTI/LMIRCam

    Get PDF
    We present the first observations obtained with the L'-band AGPM vortex coronagraph recently installed on LBTI/LMIRCam. The AGPM (Annular Groove Phase Mask) is a vector vortex coronagraph made from diamond subwavelength gratings. It is designed to improve the sensitivity and dynamic range of high-resolution imaging at very small inner working angles, down to 0.09 arcseconds in the case of LBTI/LMIRCam in the L' band. During the first hours on sky, we observed the young A5V star HR\,8799 with the goal to demonstrate the AGPM performance and assess its relevance for the ongoing LBTI planet survey (LEECH). Preliminary analyses of the data reveal the four known planets clearly at high SNR and provide unprecedented sensitivity limits in the inner planetary system (down to the diffraction limit of 0.09 arcseconds).Comment: 9 pages, 4 figures, SPIE proceeding

    Identifying New Factors Associated With Cognitive Decline and Delirium After Transcatheter Aortic Valve Implantation: A Study Protocol

    Get PDF
    Background: Transcatheter aortic valve implantation (TAVI) has become the standard-of-care for treatment of severe symptomatic aortic stenosis and is also being increasingly recommended for low-risk patients. While TAVI boasts positive post-procedural outcomes, it is also associated with cognitive complications, namely delirium and cognitive decline. There is a pressing need for accurate risk tools which can identify TAVI patients at risk of delirium and cognitive decline, as risk scores designed for general cardiovascular surgery fall short. The present effect-finding exploratory study will assess the utility of various measures in the context of aging and frailty in predicting who will and who will not develop delirium or cognitive impairment following TAVI. The measures we propose include gait, visual symptoms, voice, swallowing, mood and sleep. Methods: This is an observational prospective cohort study focused on identifying pre-procedural risk factors for the development of delirium and cognitive decline following TAVI. Potential risk factors will be measured prior to TAVI. Primary outcomes will be post-procedure cognitive decline and delirium. Secondary outcomes include activities of daily living, quality of life, and mortality. Delirium presence will be measured on each of the first 2 days following TAVI. All other outcomes will be assessed at 3-, 6-, and 12-months post-operatively. A series of logistic regressions will be run to investigate the relationship between potential predictors and outcomes (presence vs. absence of either delirium or cognitive decline). Discussion: This study will assess the strengths of associations between a range of measures drawn from frailty and aging literature in terms of association with cognitive decline and delirium following TAVI. Identified measures can be used in future development of TAVI risk prediction models, which are essential for the accurate identification of cognitive at-risk patients and successful application of pre-procedural interventions. Clinical Trial Registration: This trial is registered with the Australian New Zealand Clinical Trials Registry. [https://bit.ly/2PAotP5], [ACTRN12618001114235]
    • …
    corecore