    Low-energy X-ray radiation after the biological shielding of electron accelerators

    No full text
    The bremsstrahlung of electrons from thick converters and its passage through concrete shielding of accelerators at different angles to the axis of the electron beam were calculated using GEANT4. Numerical estimates of the residual low-energy component of X-ray radiation after passing through the biological protection were carried out at an electron energy of up to 300 MeV. Additional reasons for the possible appearance of soft X-ray radiation after the shielding are considered. Experimental measurements of the spectral and dosimetric characteristics were performed by a silicon uncooled detector with the energy resolution of ~ 1 keV and spectral sensitivity in the range 5...150 keV. The comparison of the estimated dose (using the number of counts in Si detector) with indications of dosimeters was made.Π£ GEANT4 Ρ€ΠΎΠ·Ρ€Π°Ρ…ΠΎΠ²Π°Π½ΠΎ Π³Π°Π»ΡŒΠΌΡ–Π²Π½Π΅ Π²ΠΈΠΏΡ€ΠΎΠΌΡ–Π½ΡŽΠ²Π°Π½Π½Ρ Π΅Π»Π΅ΠΊΡ‚Ρ€ΠΎΠ½Ρ–Π² Π· товстих ΠΏΠ΅Ρ€Π΅Ρ‚Π²ΠΎΡ€ΡŽΠ²Π°Ρ‡Ρ–Π² Ρ– проходТСння Π²ΠΈΠΏΡ€ΠΎΠΌΡ–Π½ΡŽΠ²Π°Π½Π½Ρ Ρ‡Π΅Ρ€Π΅Π· Π±Π΅Ρ‚ΠΎΠ½Π½Π΅ Скранування ΠΏΡ€ΠΈΡΠΊΠΎΡ€ΡŽΠ²Π°Ρ‡Ρ–Π² ΠΏΡ–Π΄ Ρ€Ρ–Π·Π½ΠΈΠΌΠΈ ΠΊΡƒΡ‚Π°ΠΌΠΈ Π΄ΠΎ осі Π΅Π»Π΅ΠΊΡ‚Ρ€ΠΎΠ½Π½ΠΎΠ³ΠΎ ΠΏΡƒΡ‡ΠΊΠ°. ΠŸΡ€ΠΎΠ²Π΅Π΄Π΅Π½Ρ– числСнні ΠΎΡ†Ρ–Π½ΠΊΠΈ Π·Π°Π»ΠΈΡˆΠΊΠΎΠ²ΠΎΡ— Π½ΠΈΠ·ΡŒΠΊΠΎΠ΅Π½Π΅Ρ€Π³Π΅Ρ‚ΠΈΡ‡Π½ΠΎΡ— складової Ρ€Π΅Π½Ρ‚Π³Π΅Π½Ρ–Π²ΡΡŒΠΊΠΎΠ³ΠΎ Π²ΠΈΠΏΡ€ΠΎΠΌΡ–Π½ΡŽΠ²Π°Π½Π½Ρ після проходТСння Π±Ρ–ΠΎΠ»ΠΎΠ³Ρ–Ρ‡Π½ΠΎΠ³ΠΎ захисту ΠΏΡ€ΠΈ Π΅Π½Π΅Ρ€Π³Ρ–Ρ— Π΅Π»Π΅ΠΊΡ‚Ρ€ΠΎΠ½Ρ–Π² Π΄ΠΎ 300 ΠœΠ΅Π’. Розглянуто Π΄ΠΎΠ΄Π°Ρ‚ΠΊΠΎΠ²Ρ– ΠΏΡ€ΠΈΡ‡ΠΈΠ½ΠΈ появи ΠΌ'якого Ρ€Π΅Π½Ρ‚Π³Π΅Π½Ρ–Π²ΡΡŒΠΊΠΎΠ³ΠΎ Π²ΠΈΠΏΡ€ΠΎΠΌΡ–Π½ΡŽΠ²Π°Π½Π½Ρ після проходТСння захисту. Π•ΠΊΡΠΏΠ΅Ρ€ΠΈΠΌΠ΅Π½Ρ‚Π°Π»ΡŒΠ½Ρ– Π²ΠΈΠΌΡ–Ρ€ΠΈ ΡΠΏΠ΅ΠΊΡ‚Ρ€Π°Π»ΡŒΠ½ΠΈΡ… Ρ‚Π° Π΄ΠΎΠ·ΠΈΠΌΠ΅Ρ‚Ρ€ΠΈΡ‡Π½ΠΈΡ… характСристик виконувалися ΠΊΡ€Π΅ΠΌΠ½Ρ–Ρ”Π²ΠΈΠΌ Π½Π΅ΠΎΡ…ΠΎΠ»ΠΎΠ΄ΠΆΠ΅Π½ΠΈΠΌ Π΄Π΅Ρ‚Π΅ΠΊΡ‚ΠΎΡ€ΠΎΠΌ Π· Π΅Π½Π΅Ρ€Π³Π΅Ρ‚ΠΈΡ‡Π½ΠΈΠΌ Π΄ΠΎΠ·Π²ΠΎΠ»ΠΎΠΌ ~ 1 ΠΊΠ΅Π’ Ρ– ΡΠΏΠ΅ΠΊΡ‚Ρ€Π°Π»ΡŒΠ½ΠΎΡŽ Ρ‡ΡƒΡ‚Π»ΠΈΠ²Ρ–ΡΡ‚ΡŽ Π² Π΄Ρ–Π°ΠΏΠ°Π·ΠΎΠ½Ρ– 5...150 ΠΊΠ΅Π’. ΠŸΡ€ΠΎΠ²Π΅Π΄Π΅Π½ΠΎ порівняння ΠΎΡ†Ρ–Π½ΠΎΡ‡Π½ΠΎΡ— Π΄ΠΎΠ·ΠΈ (Π· використанням ΠΊΡ–Π»ΡŒΠΊΠΎΡΡ‚Ρ– Π²Ρ–Π΄Π»Ρ–ΠΊΡ–Π² Ρƒ Π΄Π΅Ρ‚Π΅ΠΊΡ‚ΠΎΡ€Ρ– Si) Π· ΠΏΠΎΠΊΠ°Π·Π°ΠΌΠΈ Π΄ΠΎΠ·ΠΈΠΌΠ΅Ρ‚Ρ€Ρ–Π².Π’ GEANT4 рассчитаны Ρ‚ΠΎΡ€ΠΌΠΎΠ·Π½ΠΎΠ΅ ΠΈΠ·Π»ΡƒΡ‡Π΅Π½ΠΈΠ΅ элСктронов ΠΈΠ· толстых ΠΊΠΎΠ½Π²Π΅Ρ€Ρ‚ΠΎΡ€ΠΎΠ² ΠΈ ΠΏΡ€ΠΎΡ…ΠΎΠΆΠ΄Π΅Π½ΠΈΠ΅ излучСния Ρ‡Π΅Ρ€Π΅Π· Π±Π΅Ρ‚ΠΎΠ½Π½ΠΎΠ΅ экранированиС ускоритСлСй ΠΏΠΎΠ΄ Ρ€Π°Π·Π½Ρ‹ΠΌΠΈ ΡƒΠ³Π»Π°ΠΌΠΈ ΠΊ оси элСктронного ΠΏΡƒΡ‡ΠΊΠ°. ΠŸΡ€ΠΎΠ²Π΅Π΄Π΅Π½Ρ‹ числСнныС ΠΎΡ†Π΅Π½ΠΊΠΈ остаточной низкоэнСргСтичСской ΡΠΎΡΡ‚Π°Π²Π»ΡΡŽΡ‰Π΅ΠΉ рСнтгСновского излучСния послС прохоТдСния биологичСской Π·Π°Ρ‰ΠΈΡ‚Ρ‹ ΠΏΡ€ΠΈ энСргии элСктронов Π΄ΠΎ 300 ΠœΡΠ’. РассмотрСны Π΄ΠΎΠΏΠΎΠ»Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Π΅ ΠΏΡ€ΠΈΡ‡ΠΈΠ½Ρ‹ Π²ΠΎΠ·ΠΌΠΎΠΆΠ½ΠΎΠ³ΠΎ появлСния мягкого рСнтгСновского излучСния послС прохоТдСния Π·Π°Ρ‰ΠΈΡ‚Ρ‹. Π­ΠΊΡΠΏΠ΅Ρ€ΠΈΠΌΠ΅Π½Ρ‚Π°Π»ΡŒΠ½Ρ‹Π΅ измСрСния ΡΠΏΠ΅ΠΊΡ‚Ρ€Π°Π»ΡŒΠ½Ρ‹Ρ… ΠΈ дозимСтричСских характСристик Π²Ρ‹ΠΏΠΎΠ»Π½ΡΠ»ΠΈΡΡŒ ΠΊΡ€Π΅ΠΌΠ½ΠΈΠ΅Π²Ρ‹ΠΌ Π½Π΅ΠΎΡ…Π»Π°ΠΆΠ΄Π°Π΅ΠΌΡ‹ΠΌ Π΄Π΅Ρ‚Π΅ΠΊΡ‚ΠΎΡ€ΠΎΠΌ с энСргСтичСским Ρ€Π°Π·Ρ€Π΅ΡˆΠ΅Π½ΠΈΠ΅ΠΌ ~ 1 кэВ ΠΈ ΡΠΏΠ΅ΠΊΡ‚Ρ€Π°Π»ΡŒΠ½ΠΎΠΉ Ρ‡ΡƒΠ²ΡΡ‚Π²ΠΈΡ‚Π΅Π»ΡŒΠ½ΠΎΡΡ‚ΡŒΡŽ Π² Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½Π΅ 5...150 кэВ. ΠŸΡ€ΠΎΠ²Π΅Π΄Π΅Π½ΠΎ сравнСниС ΠΎΡ†Π΅Π½ΠΎΡ‡Π½ΠΎΠΉ Π΄ΠΎΠ·Ρ‹ (с использованиСм количСства отсчСтов Π² Π΄Π΅Ρ‚Π΅ΠΊΡ‚ΠΎΡ€Π΅ Si) с показаниями Π΄ΠΎΠ·ΠΈΠΌΠ΅Ρ‚Ρ€ΠΎΠ²
    corecore