4 research outputs found

    Development of a high-accuracy, low-cost, and portable fluorometer with smartphone application for the detection of urinary albumin towards the early screening of chronic kidney and renal diseases

    Get PDF
    This study presents the development of a portable fluorometer with a smartphone application designed to facilitate the early screening of chronic kidney and renal diseases by enabling the sensitive detection of urinary albumin. Utilizing a fluorescence-based aptasensor, the device achieved a linear calibration curve (0.001–1.5 mg/mL) with a linearity of up to 0.98022 and a detection limit of 0.203 µg/mL for human serum albumin (HSA). The analysis of 130 urine samples demonstrated comparable performance between this study’s fluorometer, a commercial fluorometer, and the standard automated method. These findings validate the feasibility of the portable fluorometer and aptasensor combination as a reliable instrument for the sensitive and specific measurement of HSA in urine samples. Moreover, the fluorometer’s portability offers potential applications in portable point-of-care testing, enhancing its utility in clinical settings for early disease screening

    Immobilization-Free Electrochemical Sensor Coupled with a Graphene-Oxide-Based Aptasensor for Glycated Albumin Detection

    No full text
    An immobilization-free electrochemical sensor coupled with a graphene oxide (GO)-based aptasensor was developed for glycated human serum albumin (GHSA) detection. The concentration of GHSA was monitored by measuring the electrochemical response of free GO and aptamer-bound GO in the presence of glycated albumin; their currents served as the analytical signals. The electrochemical aptasensor exhibited good performance with a base-10 logarithmic scale. The calibration curve was achieved in the range of 0.01–50 µg/mL. The limit of detection (LOD) was 8.70 ng/mL. The developed method was considered a one-drop measurement process because a fabrication step and the probe-immobilization process were not required. This simple sensor offers a cost-effective, rapid, and sensitive detection method, and could be an alternative approach for determination of GHSA levels

    Effects of Boric Acid and Storage Temperature on the Analysis of Microalbumin Using Aptasensor-Based Fluorescent Detection

    No full text
    The instability of human serum albumin (HSA) in urine samples makes fresh urine a requirement for microalbumin analyses using immunoturbidimetry. Here, we determined the ability of an aptasensor-based fluorescent platform to detect microalbumin in old, boric acid-preserved urine samples. Our results show that the cleavage site of protease enzymes on urine albumin protein differed from the binding position of the aptamer on HSA protein, suggesting the aptasensor may be effective for albumin detection in non-fresh urine. Furthermore, the addition of boric acid in urine samples over a short term (at ambient temperature (Ta) and 4 °C), long term (−20 and −80 °C), and following freeze–thawing (1–3 cycles) did not significantly affect albumin stability, as analyzed using the aptasensor. Therefore, boric acid stabilized has in urine stored over a short- and long-term. Thus, the aptasensor developed by us is applicable for HSA detection in boric acid-preserved urine that has been stored for 7-d at Ta and 4 °C, and in the long-term at −80 °C

    Ultrasensitive Detection of MicroRNA in Human Saliva via Rolling Circle Amplification Using a DNA-Decorated Graphene Oxide Sensor

    No full text
    MicroRNAs (miRNAs) are a family of conserved small noncoding RNAs whose expression is associated with many diseases, including cancer. Salivary miRNAs are gaining popularity as noninvasive diagnostic biomarkers for cancer and other systemic disorders, but their use is limited by their low abundance and complicated detection procedure. Herein, we present a novel self-assembly approach based on rolling circle amplification (RCA) and graphene oxide (GO) for the ultrasensitive detection of miRNA21 and miRNA16 (miRNA oral cancer biomarkers in human saliva). First, target miRNA hybridizes with the RCA template. In the presence of DNA polymerase, the RCA reaction is induced and sequences matching the template are generated. Then, a nicking enzyme cuts the long ssDNA product into tiny pieces to obtain the amplified products. The DNA-decorated GO sensor was fabricated by preabsorbing the ssDNA fluorescence-labeled probe on the GO surface, resulting in fluorescence quenching. The DNA-decorated GO sensor could detect the amplified product via the self-assembly of dsDNA, leading to the desorption and recovery of the fluorescence-labeled probe. Under optimal conditions, the proposed system exhibited ultrasensitive detection; the detection limits of miRNA16 and miRNA21 were 8.81 and 3.85 fM, respectively. It showed a wide range of detection between 10 fM and 100 pM for miRNA16 and between 10 fM and 1 nM for miRNA16. It demonstrated high selectivity, distinguishing between 1- and 3-mismatch nucleotides in target miRNA. Overall, our proposed DNA-decorated GO sensor can accurately detect the salivary miRNAs and may potentially be used for the diagnosis and screening of early-stage oral cancer
    corecore