15 research outputs found
Recommended from our members
Differential Features of Culprit Intracranial Atherosclerotic Lesions: A Whole-Brain Vessel Wall Imaging Study in Patients With Acute Ischemic Stroke.
BackgroundIntracranial atherosclerotic disease tends to affect multiple arterial segments. Using whole-brain vessel wall imaging, we sought to study the differences in plaque features among various types of plaques in patients with a recent unilateral anterior circulation ischemic stroke.Methods and resultsSixty-one patients with unilateral anterior circulation ischemic stroke were referred to undergo whole-brain vessel wall imaging (before and after contrast) within 1 month of symptom onset for intracranial atherosclerotic disease evaluations. Each plaque was classified as a culprit, probably culprit, or nonculprit lesion, according to its likelihood of causing the stroke. The associations between plaque features (thickening pattern, plaque-wall contrast ratio, high signal on T1-weighted images, plaque contrast enhancement ratio, enhancement grade, and enhancement pattern) and culprit lesions were estimated using mixed multivariable logistic regression after adjustment for maximum wall thickness. In 52 patients without motion corruption in whole-brain vessel wall imaging, a total of 178 intracranial plaques in the anterior circulation were identified, including 52 culprit lesions (29.2%), 51 probably culprit lesions (28.7%), and 75 nonculprit lesions (42.1%). High signal on T1-weighted images (adjusted odds ratio, 9.1; 95% confidence interval, 1.9-44.1; P=0.006), grade 2 (enhancement ratio of plaque ≥ enhancement ratio of pituitary) contrast enhancement (adjusted odds ratio, 17.4; 95% confidence interval, 1.8-164.9; P=0.013), and type 2 (≥50% cross-sectional wall involvement) enhancement pattern (adjusted odds ratio, 10.1; 95% confidence interval, 1.3-82.2; P=0.030) were independently associated with culprit lesions.ConclusionsHigh signal on T1-weighted images, grade 2 contrast enhancement, and type 2 enhancement pattern are associated with cerebrovascular ischemic events, which may provide valuable insights into risk stratification
Additive value of 3T cardiovascular magnetic resonance coronary angiography for detecting coronary artery disease
Abstract Background The purpose of the work was to evaluate the incremental diagnostic value of free-breathing, contrast-enhanced, whole-heart, 3 T cardiovascular magnetic resonance coronary angiography (CE-MRCA) to stress/rest myocardial perfusion imaging (MPI) and late gadolinium enhancement (LGE) imaging for detecting coronary artery disease (CAD). Methods Fifty-one patients with suspected CAD underwent a comprehensive cardiovascular magnetic resonance (CMR) examination (CE-MRCA, MPI, and LGE). The additive diagnostic value of MRCA to MPI and LGE was evaluated using invasive x-ray coronary angiography (XA) as the standard for defining functionally significant CAD (≥ 50% stenosis in vessels > 2 mm in diameter). Results 90.2% (46/51) patients (54.0 ± 11.5 years; 71.7% men) completed CE-MRCA successfully. On per-patient basis, compared to MPI/LGE alone or MPI alone, the addition of MRCA resulted in higher sensitivity (100% vs. 76.5%, p < 0.01), no change in specificity (58.3% vs. 66.7%, p = 0.6), and higher accuracy (89.1% vs 73.9%, p < 0.01) for CAD detection (prevalence = 73.9%). Compared to LGE alone, the addition of CE-MRCA resulted in higher sensitivity (97.1% vs. 41.2%, p < 0.01), inferior specificity (83.3% vs. 91.7%, p = 0.02), and higher diagnostic accuracy (93.5% vs. 54.3%, p < 0.01). Conclusion The inclusion of successful free-breathing, whole-heart, 3 T CE-MRCA significantly improved the sensitivity and diagnostic accuracy as compared to MPI and LGE alone for CAD detection
Recommended from our members
MR Multitasking‐based multi‐dimensional assessment of cardiovascular system (MT‐MACS) with extended spatial coverage and water‐fat separation
PurposeTo extend the MR MultiTasking-based Multidimensional Assessment of Cardiovascular System (MT-MACS) technique with larger spatial coverage and water-fat separation for comprehensive aortocardiac assessment.MethodsMT-MACS adopts a low-rank tensor image model for 7D imaging, with three spatial dimensions for volumetric imaging, one cardiac motion dimension for cine imaging, one respiratory motion dimension for free-breathing imaging, one T2-prepared inversion recovery time dimension for multi-contrast assessment, and one T2*-decay time dimension for water-fat separation. Nine healthy subjects were recruited for the 3T study. Overall image quality was scored on bright-blood (BB), dark-blood (DB), and gray-blood (GB) contrasts using a 4-point scale (0-poor to 3-excellent) by two independent readers, and their interreader agreement was evaluated. Myocardial wall thickness and left ventricular ejection fraction (LVEF) were quantified on DB and BB contrasts, respectively. The agreement in these metrics between MT-MACS and conventional breath-held, electrocardiography-triggered 2D sequences were evaluated.ResultsMT-MACS provides both water-only and fat-only images with excellent image quality (average score = 3.725/3.780/3.835/3.890 for BB/DB/GB/fat-only images) and moderate to high interreader agreement (weighted Cohen's kappa value = 0.727/0.668/1.000/1.000 for BB/DB/GB/fat-only images). There were good to excellent agreements in myocardial wall thickness measurements (intraclass correlation coefficients [ICC] = 0.781/0.929/0.680/0.878 for left atria/left ventricle/right atria/right ventricle) and LVEF quantification (ICC = 0.716) between MT-MACS and 2D references. All measurements were within the literature range of healthy subjects.ConclusionThe refined MT-MACS technique provides multi-contrast, phase-resolved, and water-fat imaging of the aortocardiac systems and allows evaluation of anatomy and function. Clinical validation is warranted
3D whole-brain vessel wall cardiovascular magnetic resonance imaging: a study on the reliability in the quantification of intracranial vessel dimensions
Abstract Background One of the potentially important applications of three-dimensional (3D) intracranial vessel wall (IVW) cardiovascular magnetic resonance (CMR) is to monitor disease progression and regression via quantitative measurement of IVW morphology during medical management or drug development. However, a prerequisite for this application is to validate that IVW morphologic measurements based on the modality are reliable. In this study we performed comprehensive reliability analysis for the recently proposed whole-brain IVW CMR technique. Methods Thirty-four healthy subjects and 10 patients with known intracranial atherosclerotic disease underwent repeat whole-brain IVW CMR scans. In 19 of the 34 subjects, two-dimensional (2D) turbo spin-echo (TSE) scan was performed to serve as a reference for the assessment of vessel dimensions. Lumen and wall volume, normalized wall index, mean and maximum wall thickness were measured in both 3D and 2D IVW CMR images. Scan-rescan, intra-observer, and inter-observer reproducibility of 3D IVW CMR in the quantification of IVW or plaque dimensions were respectively assessed in volunteers and patients as well as for different healthy subjectsub-groups (i.e. 0.75). In addition, all ICCs of patients were equal to or higher than that of healthy subjects except maximum wall thickness. In volunteers, all ICCs of the age group of ≥50 years were equal to or higher than that of the age group of < 50 years. Normalized wall index and mean and maximum wall thickness were significantly larger in the age group of ≥50 years. To detect 5% - 20% difference between placebo and treatment groups, normalized wall index requires the smallest sample size while lumen volume requires the highest sample size. Conclusions Whole-brain 3D IVW CMR is a reliable imaging method for the quantification of intracranial vessel dimensions and could potentially be useful for monitoring plaque progression and regression
Recommended from our members
3D whole-brain vessel wall cardiovascular magnetic resonance imaging: a study on the reliability in the quantification of intracranial vessel dimensions.
BACKGROUND:One of the potentially important applications of three-dimensional (3D) intracranial vessel wall (IVW) cardiovascular magnetic resonance (CMR) is to monitor disease progression and regression via quantitative measurement of IVW morphology during medical management or drug development. However, a prerequisite for this application is to validate that IVW morphologic measurements based on the modality are reliable. In this study we performed comprehensive reliability analysis for the recently proposed whole-brain IVW CMR technique. METHODS:Thirty-four healthy subjects and 10 patients with known intracranial atherosclerotic disease underwent repeat whole-brain IVW CMR scans. In 19 of the 34 subjects, two-dimensional (2D) turbo spin-echo (TSE) scan was performed to serve as a reference for the assessment of vessel dimensions. Lumen and wall volume, normalized wall index, mean and maximum wall thickness were measured in both 3D and 2D IVW CMR images. Scan-rescan, intra-observer, and inter-observer reproducibility of 3D IVW CMR in the quantification of IVW or plaque dimensions were respectively assessed in volunteers and patients as well as for different healthy subjectsub-groups (i.e. < 50 and ≥ 50 years). The agreement in vessel wall and lumen measurements between the 3D technique and the 2D TSE method was also investigated. In addition, the sample size required for future longitudinal clinical studies was calculated. RESULTS:The intra-class correlation coefficient (ICC) and Bland-Altman plots indicated excellent reproducibility and inter-method agreement for all morphologic measurements (All ICCs > 0.75). In addition, all ICCs of patients were equal to or higher than that of healthy subjects except maximum wall thickness. In volunteers, all ICCs of the age group of ≥50 years were equal to or higher than that of the age group of < 50 years. Normalized wall index and mean and maximum wall thickness were significantly larger in the age group of ≥50 years. To detect 5% - 20% difference between placebo and treatment groups, normalized wall index requires the smallest sample size while lumen volume requires the highest sample size. CONCLUSIONS:Whole-brain 3D IVW CMR is a reliable imaging method for the quantification of intracranial vessel dimensions and could potentially be useful for monitoring plaque progression and regression
Magnetic resonance multitasking for multidimensional assessment of cardiovascular system: Development and feasibility study on the thoracic aorta
PurposeTo develop an MR multitasking-based multidimensional assessment of cardiovascular system (MT-MACS) with electrocardiography-free and navigator-free data acquisition for a comprehensive evaluation of thoracic aortic diseases.MethodsThe MT-MACS technique adopts a low-rank tensor image model with a cardiac time dimension for phase-resolved cine imaging and a T2 -prepared inversion-recovery dimension for multicontrast assessment. Twelve healthy subjects and 2 patients with thoracic aortic diseases were recruited for the study at 3 T, and both qualitative (image quality score) and quantitative (contrast-to-noise ratio between lumen and wall, lumen and wall area, and aortic strain index) analyses were performed in all healthy subjects. The overall image quality was scored based on a 4-point scale: 3, excellent; 2, good; 1, fair; and 0, poor. Statistical analysis was used to test the measurement agreement between MT-MACS and its corresponding 2D references.ResultsThe MT-MACS images reconstructed from acquisitions as short as 6 minutes demonstrated good or excellent image quality for bright-blood (2.58 ± 0.46), dark-blood (2.58 ± 0.50), and gray-blood (2.17 ± 0.53) contrast weightings, respectively. The contrast-to-noise ratios for the three weightings were 49.2 ± 12.8, 20.0 ± 5.8 and 2.8 ± 1.8, respectively. There were good agreements in the lumen and wall area (intraclass correlation coefficient = 0.993, P < .001 for lumen; intraclass correlation coefficient = 0.969, P < .001 for wall area) and strain (intraclass correlation coefficient = 0.947, P < .001) between MT-MACS and conventional 2D sequences.ConclusionThe MT-MACS technique provides high-quality, multidimensional images for a comprehensive assessment of the thoracic aorta. Technical feasibility was demonstrated in healthy subjects and patients with thoracic aortic diseases. Further clinical validation is warranted