3,232 research outputs found

    Development of Design Criteria for Sensitizer Photooxidation Treatment Systems

    Get PDF
    Sensitized photooxidation is a physicochemical process that can degrade many toxic and refractory organic pollutants. A trace quantity of sensitizer added to the waste absorbs visible light; electronically excited intermediates then transfer the energy to decompose the waste. Engeineering design criteria were developed for industrial waste treatment lagoons that would use sensitized photooxidation. Design criteria were developed regarding optimum lagoon pH, optimum sensitizer concentration, depth and sizing of lagoons, dissolved oxygen requirements, and effect of temperature on photooxidation rate. Treatment of the refractory pesticides bromacil, terbacil, and fluometuron was investigated using methylene blue and riboflavin as sensitizers. Methylene blue-sensitized photooxidation of the three pesticides was most efficient at basic pH. The optimum pH of riboflavin-sensitized photooxidaction varied and was substrate-dependent. A model was developed to predict sensitized photooxidation rate as a function of lagoon depth. The model is based on light intesnity, sensitizer extinction coefficient, and an applied quantum yeirld, all of which are integrated over wavelengths of visible light. The model serves as the basis of sizing photooxidation lagoons. A dissolved oxygen residual of 1 mg/1 was required to maintain maximum methylene blue-sensitized photooxidation rate. At least 4 mg/1 dissolved oxygen was necessary to maintain riboflavin-sensitized phooxidation at maximum levels. Oxygen uptake rates in sensitized phooxidation reactions were proportional to the concentration of substrate. Temperatures from 10 degrees to 35 degreees Celcius had no significant effect on sensitized photooxidation rates. Using the model developed, a methylene blue-sensitized phooxidation pilot lagoon was designed to treat a 30 mg/1 bromacil influent concentraion to 0.1 mg/1 bromacil in the effluent. For an influent flow of 0.263 m^3/min (0.1 MGD) waste, a 0.1 mg/1 methylene blue concentration, 36 cm depth, and 1870 m^2 surface area are required. A cost analysis was performed which indicated that sensitized photooxidation lagoons appear to be cost-compentitive with other industrial waste treatement systems

    Eigenvector Continuation and Projection-Based Emulators

    Full text link
    Eigenvector continuation is a computational method for parametric eigenvalue problems that uses subspace projection with a basis derived from eigenvector snapshots from different parameter sets. It is part of a broader class of subspace-projection techniques called reduced-basis methods. In this colloquium article, we present the development, theory, and applications of eigenvector continuation and projection-based emulators. We introduce the basic concepts, discuss the underlying theory and convergence properties, and present recent applications for quantum systems and future prospects.Comment: 20 pages, 17 figure

    Connector adapter

    Get PDF
    An adapter for installing a connector to a terminal post, wherein the connector is attached to a cable, is presented. In an embodiment, the adapter is comprised of an elongated collet member having a longitudinal axis comprised of a first collet member end, a second collet member end, an outer collet member surface, and an inner collet member surface. The inner collet member surface at the first collet member end is used to engage the connector. The outer collet member surface at the first collet member end is tapered for a predetermined first length at a predetermined taper angle. The collet includes a longitudinal slot that extends along the longitudinal axis initiating at the first collet member end for a predetermined second length. The first collet member end is formed of a predetermined number of sections segregated by a predetermined number of channels and the longitudinal slot

    Analysis of Dislocation Mechanism for Melting of Elements: Pressure Dependence

    Full text link
    In the framework of melting as a dislocation-mediated phase transition we derive an equation for the pressure dependence of the melting temperatures of the elements valid up to pressures of order their ambient bulk moduli. Melting curves are calculated for Al, Mg, Ni, Pb, the iron group (Fe, Ru, Os), the chromium group (Cr, Mo, W), the copper group (Cu, Ag, Au), noble gases (Ne, Ar, Kr, Xe, Rn), and six actinides (Am, Cm, Np, Pa, Th, U). These calculated melting curves are in good agreement with existing data. We also discuss the apparent equivalence of our melting relation and the Lindemann criterion, and the lack of the rigorous proof of their equivalence. We show that the would-be mathematical equivalence of both formulas must manifest itself in a new relation between the Gr\"{u}neisen constant, bulk and shear moduli, and the pressure derivative of the shear modulus.Comment: 19 pages, LaTeX, 9 eps figure

    Erenumab in chronic migraine: Patient-reported outcomes in a randomized double-blind study.

    Get PDF
    OBJECTIVE: To determine the effect of erenumab, a human monoclonal antibody targeting the calcitonin gene-related peptide receptor, on health-related quality of life (HRQoL), headache impact, and disability in patients with chronic migraine (CM). METHODS: In this double-blind, placebo-controlled study, 667 adults with CM were randomized (3:2:2) to placebo or erenumab (70 or 140 mg monthly). Exploratory endpoints included migraine-specific HRQoL (Migraine-Specific Quality-of-Life Questionnaire [MSQ]), headache impact (Headache Impact Test-6 [HIT-6]), migraine-related disability (Migraine Disability Assessment [MIDAS] test), and pain interference (Patient-Reported Outcomes Measurement Information System [PROMIS] Pain Interference Scale short form 6b). RESULTS: Improvements were observed for all endpoints in both erenumab groups at month 3, with greater changes relative to placebo observed at month 1 for many outcomes. All 3 MSQ domains were improved from baseline with treatment differences for both doses exceeding minimally important differences established for MSQ-role function-restrictive (≥3.2) and MSQ-emotional functioning (≥7.5) and for MSQ-role function-preventive (≥4.5) for erenumab 140 mg. Changes from baseline in HIT-6 scores at month 3 were -5.6 for both doses vs -3.1 for placebo. MIDAS scores at month 3 improved by -19.4 days for 70 mg and -19.8 days for 140 mg vs -7.5 days for placebo. Individual-level minimally important difference was achieved by larger proportions of erenumab-treated participants than placebo for all MSQ domains and HIT-6. Lower proportions of erenumab-treated participants had MIDAS scores of severe (≥21) or very severe (≥41) or PROMIS scores ≥60 at month 3. CONCLUSIONS: Erenumab-treated patients with CM experienced clinically relevant improvements across a broad range of patient-reported outcomes. CLINICALTRIALSGOV IDENTIFIER: NCT02066415. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that for patients with CM, erenumab treatment improves HRQoL, headache impact, and disability

    Hydraulic Apparatus for Mechanical Testing of Nuts

    Get PDF
    The figure depicts an apparatus for mechanical testing of nuts. In the original application for which the apparatus was developed, the nuts are of a frangible type designed for use with pyrotechnic devices in spacecraft applications in which there are requirements for rapid, one-time separations of structures that are bolted together. The apparatus can also be used to test nonfrangible nuts engaged without pyrotechnic devices. This apparatus was developed to replace prior testing systems that were extremely heavy and immobile and characterized by long setup times (of the order of an hour for each nut to be tested). This apparatus is mobile, and the setup for each test can now be completed in about five minutes. The apparatus can load a nut under test with a static axial force of as much as 6.8 x 10(exp 5) lb (3.0 MN) and a static moment of as much as 8.5 x 10(exp 4) lb in. (9.6 x 10(exp 3) N(raised dot)m) for a predetermined amount of time. In the case of a test of a frangible nut, the pyrotechnic devices can be exploded to break the nut while the load is applied, in which case the breakage of the nut relieves the load. The apparatus can be operated remotely for safety during an explosive test. The load-generating portion of the apparatus is driven by low-pressure compressed air; the remainder of the apparatus is driven by 110-Vac electricity. From its source, the compressed air is fed to the apparatus through a regulator and a manually operated valve. The regulated compressed air is fed to a pneumatically driven hydraulic pump, which pressurizes oil in a hydraulic cylinder, thereby causing a load to be applied via a hydraulic nut (not to be confused with the nut under test). During operation, the hydraulic pressure is correlated with the applied axial load, which is verified by use of a load cell. Prior to operation, one end of a test stud (which could be an ordinary threaded rod or bolt) is installed in the hydraulic nut. The other end of the test stud passes through a bearing plate; a load cell is slid onto that end, and then the nut to be tested is threaded onto that end and tightened until the nut and load cell press gently against the bearing plate
    corecore