2,236 research outputs found

    Developments of the pinned photodiode terahertz rectifier

    Get PDF
    This paper presents we presents a development of the structure of the pinned photodiode terahertz rectifier, in which the metal whisker of the antenna is separated from the semiconductor by a silane oxide layer, in order to reduce the surface defectiveness. The rectifies is the basic component of an image detection system based on the structure of actual CMOS image detectors. The structure combines a nano-antenna, fabricated on the top of a standard image sensor, the rectifier, and the readout electronics. The rectifier device proposed has vertical extension of some tenths of nanometers, can be created at the foot of the nano-whisker at the end of the terahertz antenna, above the storage well

    Cervico-mediastinal schwannoma of the vagus nerve: resection with intraoperative nerve monitoring.

    Get PDF
    Schwannomas are usually benign, single, encapsulated, slow-growing tumours originating from cranial or spinal nerve sheaths. The vagus nerve involvement at the mediastinal inlet is very uncommon. For anatomical reasons, the resection of cervical and mediastinal schwannoma of the vagus nerve has a high risk of vocal fold paralysis. We describe the case of a 67-year-old female with a cervico-mediastinal schwannoma of the vagus nerve that we removed using the intraoperative neuromonitoring technique. The patient presented with mild hoarseness and complained of discomfort behind the jugular notch. Neck and chest computerized tomography described a 35 9 30 mm solid lesion behind the left clavi-sternal junction; preoperative fine needle aspiration cytology revealed schwannoma. Resection of the mass was performed with a cervical approach and the vagus nerve tumour was completely removed under continuous neuromonitoring (NIM-3 System), preserving the vagus and the recurrent laryngeal nerve function. Pathology on the resected mass documented A-type schwannoma with \u2018\u2018ancient schwannoma\u2019\u2019 areas. The intraoperative neurostimulation and neuromonitoring approach for the resection of vagus schwannoma are recommended because it may reduce the risk of injury to the vagus and to the recurrent laryngeal nerve

    Design, synthesis and biological activity of selective hCAs inhibitors based on 2-(benzylsulfinyl)benzoic acid scaffold

    Get PDF
    A large library of derivatives based on the scaffold of 2-(benzylsulfinyl)benzoic acid were synthesised and tested as atypical inhibitors against four different isoforms of human carbonic anhydrase (hCA I, II, IX and XII, EC 4.2.1.1). The exploration of the chemical space around the main functional groups led to the discovery of selective hCA IX inhibitors in the micromolar/nanomolar range, thus establishing robust structure-activity relationships within this versatile scaffold. HPLC separation of some selected chiral compounds and biological evaluation of the corresponding enantiomers was performed along with molecular modelling studies on the most active derivatives

    Low-Complexity Downlink Channel Estimation in mmWave Multiple-Input Single-Output Systems

    Get PDF
    This paper tackles the problem of channel estimation in mmWave multiple-input single-output systems, where users are equipped with single-antenna receivers. By leveraging broadcast transmissions in the downlink channel, two novel low-complexity estimation approaches are devised, able to operate even in presence of a reduced number of transmit antennas or limited bandwidth. Numerical results show that the proposed algorithms provide accurate estimates of the channel parameters, achieving at the same time about 50% complexity reduction compared to existing approaches

    Modeling and Measuring Thermodynamic and Transport Thermophysical Properties: A Review

    Get PDF
    The present review describes the up-to-date state of the evaluation of thermophysical prop erties (TP) of materials with three different procedures: modeling (also including inverse problems), measurements and analytical methods (e.g., through computing from other properties). Methods to measure specific heat and thermal conductivity are described in detail. Thermal diffusivity and thermal effusivity are a combination of the previously cited properties, but also for these proper ties, specific measurement and calculation methods are reported. Experiments can be carried out in steady-state, transient, and pulse regimes. For modeling, special focus is given to the inverse methods and parameter estimation procedures, because through them it is possible to evaluate the thermophysical property, assuring the best practices and supplying the measurement uncertainty. It is also cited when the most common data processing algorithms are used, e.g., the Gauss–Newton and Levenberg–Marquardt least squares minimization algorithms, and how it is possible to retrieve values of TP from other data. Optimization criteria for designing the experiments are also mentione

    Avaliação quantitativa e qualitativa de alface cultivada em sistema zeopônico.

    Get PDF
    O objetivo deste trabalho foi avaliar e relacionar os aspectos quantitativos (produção e teores foliares de nutrientes), e os qualitativos (aparência) de alfaces cultivadas em substratos com zeólitas enriquecidas com NPK, bem como verificar avaliar as frequências de compra e de consumo, e os fatores de escolha na aquisição da alface por um grupo específico de consumidores.bitstream/CNPS/11861/1/alface_zeoponico.pd
    corecore