199 research outputs found

    Erythropoietic protoporphyria

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/73642/1/j.1537-2995.2004.04058.x.pd

    Anti-A and anti-B titers in pooled group O platelets are comparable to apheresis platelets

    Full text link
    Although uncommon, acute hemolytic transfusion reactions (AHTRs) have been reported after transfusion of group O single-donor apheresis platelets (SDPs) to group A, B, and AB recipients. Current methods for identifying “high-titer” SDPs include tube and gel methods. The risk of a high-titer unit is considered low with group O, poststorage, pooled platelet concentrates (PPLTs); however, data regarding anti-A and anti-B titers in PPLTs are lacking. STUDY DESIGN AND METHODS: Anti-A and anti-B titers were determined in 185 PPLTs by direct agglutination using manual gel and tube methods. PPLTs tested included 124 group O PPLTs, 25 group A PPLTs, 26 group B PPLTs, and 10 PPLTs containing a mix of either groups O plus A or groups O plus B (mixed PPLTs). The reciprocal of the highest dilution giving macroscopic agglutination was considered the agglutinin titer. RESULTS: Mean anti-A and anti-B titers in group O PPLTs were, respectively, 16 and 8 by tube and 64 and 32 by gel (p < 0.0001). Gel titers were one to two dilutions higher than tube and sensitive to reagent red cell lots. With the use of at least 64 as a critical titer, 60 percent of group O PPLTs tested by gel would be considered high-titer. In mixed PPLTs, the addition of one non-group O PLT significantly decreased or neutralized the corresponding anti-A or anti-B (p < 0.0001). CONCLUSION: Anti-A and anti-B titers in group O PPLTs are comparable to those reported in group O SDPs and significantly lower than titers reported in AHTR. A critical direct agglutinin titer of 64 for identifying high-titer units by gel is too low and should be increased to 128 or higher.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/73545/1/j.1537-2995.2008.01814.x.pd

    Revisiting the issue: can the reading for serologic reactivity following 37°C incubation be omitted?

    Full text link
    Omitting the 37°C reading from screening tests for unexpected antibodies results in failure to detect some Rh, K, and Jk agglutinins of potential significance (wanted positives). However, this measure avoids unwanted positive tests due to cold agglutinins. STUDY DESIGN AND METHODS : Using data from prior publications, actual risk calculations (ARCs) were made to predict the risk of eliminating the 37°C reading, pretransfusion direct antiglobulin test (DAT), and routine indirect antiglobulin crossmatch (IAT-XM). ARCs used the equation: wanted positives missed × 0.34 (or 0.80) × 5 × percent antigen-positive, where 0.34 = percent of patients transfused (ARCs for 37°C reading and DAT); 0.80 = percent of crossmatched patients transfused (ARCs for IAT-XM); 5 = average number of units transfused. Following elimination of the 37°C reading, the impact of this change on patient care was monitored. Antibody detection and identification data and transfusion reaction reports for 6 months after the change were reviewed. Recently transfused patients with new antibodies were evaluated for immune hemolysis by review of clinical and laboratory data. The findings were compared with those from the same dates of the preceding year. RESULTS : The risk of transfusing incompatible blood by eliminating the DAT, IAT-XM, and 37°C reading is approximately 1:13,000, 1:2,000, and 1:2,400 units transfused, respectively. The cumulative risk from eliminating all three tests is approximately. 1:1,000 units. With respect to the 37°C reading, there were no differences between the pre-change and post-change study periods in the incidence of reported transfusion reactions or cases of immune hemolysis associated with newly formed antibodies. However, unwanted positive tests decreased from 162 to 61 following elimination of the 37°C reading. This represents a decrease of 20 percent in the number of samples requiring antibody identification annually. CONCLUSIONS : Eliminating the 37°C reading from pretransfusion antibody screening tests imposes less risk than omitting the routine IAT-XM, and it avoids the time and costs of evaluating unwanted positive tests, thus reducing expenditures and delays in patient care.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/74728/1/j.1537-2995.1999.39399219287.x.pd

    Packed Red Blood Cells Are an Abundant and Proximate Potential Source of Nitric Oxide Synthase Inhibition

    Get PDF
    <div><p>Objective</p><p>We determined, for packed red blood cells (PRBC) and fresh frozen plasma, the maximum content, and ability to release the endogenous nitric oxide synthase (NOS) inhibitors asymmetric dimethylarginine (ADMA) and monomethylarginine (LNMMA).</p><p>Background</p><p>ADMA and LNMMA are near equipotent NOS inhibitors forming blood’s total NOS inhibitory content. The balance between removal from, and addition to plasma determines their free concentrations. Removal from plasma is by well-characterized specific hydrolases while formation is restricted to posttranslational protein methylation. When released into plasma they can readily enter endothelial cells and inhibit NOS. Fresh rat and human whole blood contain substantial protein incorporated ADMA however; the maximum content of ADMA and LNMMA in PRBC and fresh frozen plasma has not been determined.</p><p>Methods</p><p>We measured total (free and protein incorporated) ADMA and LNMMA content in PRBCs and fresh frozen plasma, as well as their incubation induced release, using HPLC with fluorescence detection. We tested the hypothesis that PRBC and fresh frozen plasma contain substantial inhibitory methylarginines that can be released chemically by complete <i>in vitro</i> acid hydrolysis or physiologically at 37°C by enzymatic blood proteolysis.</p><p>Results</p><p><i>In vitro</i> strong-acid-hydrolysis revealed a large PRBC reservoir of ADMA (54.5 ± 9.7 ”M) and LNMMA (58.9 ± 28.9 ÎŒM) that persisted over 42-d at 6° or -80°C. <i>In vitro</i> 5h incubation at 37°C nearly doubled free ADMA and LNMMNA concentration from PRBCs while no change was detected in fresh frozen plasma.</p><p>Conclusion</p><p>The compelling physiological ramifications are that regardless of storage age, 1) PRBCs can rapidly release pathologically relevant quantities of ADMA and LNMMA when incubated and 2) PRBCs have a protein-incorporated inhibitory methylarginines reservoir 100 times that of normal free inhibitory methylarginines in blood and thus could represent a clinically relevant and proximate risk for iatrogenic NOS inhibition upon transfusion.</p></div

    Exaggerated pigmented granulomatous reaction to the artificial joint implant mimics metastatic melanoma

    Full text link
    Total joint replacement is a common orthopedic procedure. An artificial joint implant may fail due to mechanical mishap and a granulomatous reaction can be induced by the artificial joint debris after the mechanical failure. We report a case of an exaggerated pigmented granulomatous tissue response to metallic artificial joint implant debris in a 72-yr-old male that was mistaken for metastatic melanoma. The mass was soft, pigmented, ill-defined, and located in the right inguinal region. Fine-needle aspiration revealed numerous black-pigment laden cells. The cellular features were frequently obscured by the heavy pigmentation. Occasional cells exhibited atypia and prominent nucleoli. There were also abundant extracellular irregular small black particles dispersed in the background. The diagnosis of melanoma involving a lymph node was made. Since there was no prior history of melanoma, it was presumed that this represented metastatic melanoma from an unknown primary. A subsequent exploration of the groin was performed with the intent to resect the disease. At exploration, the mass was found to be contiguous with the hip joint and the frozen section of the mass revealed no evidence of melanoma. The final tissue diagnosis confirmed the frozen section report and showed a granulomatous reaction. This report underscores the diagnostic dilemma associated with the exaggerated pigmented granulomatous reaction due to an artificial prosthesis. Diagn. Cytopathol. 2004;30:198–200. © 2004 Wiley-Liss, Inc.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/35313/1/20006_ftp.pd
    • 

    corecore