267 research outputs found

    Vortex shape in unbaffled stirred vessels: experimental study via digital image analysis

    Get PDF
    There is a growing interest in using unbaffled stirred tanks for addressing certain processing needs. In this work, digital image analysis coupled with a suitable shadowgraphy-based technique is used to investigate the shape of the free-surface vortex that forms in uncovered unbaffled stirred tanks. The technique is based on back-lighting the vessel and suitably averaging vortex shape over time. Impeller clearance from vessel bottom and tank filling level are varied to investigate their influence on vortex shape. A correlation is finally proposed to fully describe vortex shape also when the vortex encompasses the impeller

    Correlation between Migraine Severity and Cholesterol Levels.

    Get PDF
    INTRODUCTION: Several studies have documented increased cardiovascular risk factors, particularly hypercholesterolemia, in the migraine population with respect to controls. However, no studies have investigated the possible relationship between headache severity parameters and lipid serum levels. METHODS: This study evaluated the lipid asset in 52 migraine patients (17 with and 36 without aura) before and after treatment with drugs for migraine prophylaxis for 3 months. RESULTS: High frequency (HF, ≥ 8/month) and intensity (HI, ≥ 5 Numeric Rating Score) vs. low frequency (LF, < 8/month) and intensity (LI, < 5) of crises were associated with significantly higher cholesterol levels, both total (TC, HF vs. LF, P < 0.0001; HI vs. LI, P < 0.0001) and LDL (LDL-c, HF vs. LF, P < 0.0001, and HI vs. LI, P < 0.0001). In treated patients, a significant decrease in number and intensity of crises was associated with a significant reduction of TC and LDL-c (P < 0.001). A direct linear correlation was also found between frequency and intensity of crises and lipid levels (TC/frequency, P < 0.0001; TC/intensity, P < 0.0001; LDL-c/frequency, P < 0.0001; LDL-c/intensity, P < 0.0001). No significant difference was found in the evaluated parameters for the subgroups of patients with and without aura. DISCUSSION: This study shows a significant positive association between migraine frequency and intensity with total and LDL cholesterol, demonstrating for the first time a significant reduction of these lipid parameters after migraine prophylaxis. However, in view of the retrospective design of the study and the small population size, these results should be considered as preliminary, to be confirmed by future prospective controlled trials

    Disease activity states, reasons for discontinuation and adverse events in 1038 Italian children with juvenile idiopathic arthritis treated with etanercept

    Get PDF
    The advent of biologic medications has increased considerably the potential for treatment benefit in juvenile idiopathic arthritis (JIA), with clinical remission being now achievable in a substantial proportion of patients. However, there is a need of data from the real world of clinical practice to evaluate thoroughly the efficacy and safety profile of the biologic agents currently approved

    Correction of B-scan distortion for optimum ultrasonic imaging of back walls with complex geometries

    Get PDF
    Ultrasound undergoes refraction and reflection at interfaces between media of different acoustic refractive indices. The most common ultrasonic method (pulse-echo) monitors the reflected energy to infer the presence of flaws, whereas the lower amplitude of refracted signals is ignored. When the reflector is orientated normally with respect to the ultrasonic beam, the received echo signal shows the maximum amplitude. The pulse-echo method also relies on monitoring the amplitude of the backwall echo to identify or confirm the presence of defects. This works well for parts with constant thickness and with planar backwalls. Unfortunately, parts with complex backwalls are common to many industrial sectors. For example, applications such as aerospace structures often require parts with complex shapes. Assessing such parts reliably is not trivial and can cause severe downtime in the aerospace manufacturing processes or during in-service inspections. This work aims to improve the ultrasonic inspectability of parts with complex backwalls, through sending ultrasonic beams from the frontwall side. Ultrasonic phased array probes and state-of-the-art instrumentation allow ultrasonic energy to be sent into a part at wide ranges of focusing depths and steering angles. This allows for tracking of the backwall profile, thus hitting it normally and maximising the amplitude of the reflected echo at any point. However, this work has shown that a cross-sectional scan resulting from multiple ultrasonic beams, which are sent at variable incidence angles, can present significant geometrical distortion and cannot be of much use for accurate defect visualisation and sizing. This paper introduces a generalised algorithm developed to remove geometric distortions and the effect that variable refraction coefficients have on the transmitted and received amplitudes. The algorithm was validated through CIVA simulations for two example parts with complex backwalls, considering isotropic materials

    Lifespan theorem for constrained surface diffusion flows

    Get PDF
    We consider closed immersed hypersurfaces in R3\R^{3} and R4\R^4 evolving by a class of constrained surface diffusion flows. Our result, similar to earlier results for the Willmore flow, gives both a positive lower bound on the time for which a smooth solution exists, and a small upper bound on a power of the total curvature during this time. By phrasing the theorem in terms of the concentration of curvature in the initial surface, our result holds for very general initial data and has applications to further development in asymptotic analysis for these flows.Comment: 29 pages. arXiv admin note: substantial text overlap with arXiv:1201.657
    corecore