12 research outputs found

    A new fasciocutaneous flap model identifies a critical role for endothelial Notch signaling in wound healing and flap survival.

    Get PDF
    Flap surgery is a common treatment for severe wounds and a major determinant of surgical outcome. Flap survival and healing depends on adaptation of the local flap vasculature. Using a novel and defined model of fasciocutaneous flap surgery, we demonstrate that the Notch ligand Delta-like 1 (Dll1), expressed in vascular endothelial cells, regulates flap arteriogenesis, inflammation and flap survival. Utilizing the stereotyped anatomy of dorsal skin arteries, ligation of the major vascular pedicle induced strong collateral vessel development by end-to-end anastomosis in wildtype mice, which supported flap perfusion recovery over time. In mice with heterozygous deletion of Dll1, collateral vessel formation was strongly impaired, resulting in aberrant vascularization and subsequent necrosis of the tissue. Furthermore, Dll1 deficient mice showed severe inflammation in the flap dominated by monocytes and macrophages. This process is controlled by endothelial Dll1 in vivo, since the results were recapitulated in mice with endothelial-specific deletion of Dll1. Thus, our model provides a platform to study vascular adaptation to flap surgery and molecular and cellular regulators influencing flap healing and survival

    Personalized Treatment Decisions for Traumatic Proximal Finger Amputations: A Retrospective Cohort Study

    No full text
    Ray and proximal phalanx amputations present valid surgical options for the management of severe traumatic finger injuries. However, among these procedures, the superior one for optimal functionality and quality of life for patients still remains unknown. This retrospective cohort study compares the postoperative effects of each amputation type to provide objective evidence and to create a paradigm for clinical decision-making. A total of forty patients who had received either ray or proximal phalanx-level amputations reported on their functional outcomes using a combination of questionnaires and clinical testing. We found a decreased overall DASH score following ray amputation. Particularly, Part A and Part C of the DASH questionnaire were consistently lower compared with amputation at the proximal phalanx. Pain measurements in the affected hand were also significantly decreased during work and at rest in ray amputation patients, and they reported decreased cold sensitivity. Range of motion and grip strength were lower in ray amputations, which is an important preoperative consideration. We found no significant differences in reported health condition, evaluated according to the EQ-5D-5L, and blood circulation in the affected hand. We present an algorithm for clinical decision-making based on patients’ preferences to personalize treatment

    Blood Vessel Injuries of the Fingers: A Clinical Comparison of One- and Two-Arterial Blood Supply

    No full text
    Traumatic finger injuries are very common in emergency medicine. When patients present with finger injuries, there is often damage to the vascular nerve bundles, which requires subsequent reconstruction. It is unknown if repairing a unilaterally injured artery affects patients’ recovery in a well-perfused finger. This retrospective cohort study compares the clinical outcomes of 11 patients with one-vessel supply (mean age 48.3 years; 7 males, 4 females) to 14 patients with two-vessel supply (mean age 44.5 years; 8 males, 6 females). The patient outcomes were assessed using patient questionnaires (Disabilities of Arm, Shoulder, and Hand (DASH), European Quality of Life 5 Dimensions 5 Level Version (EQ-5D-5L), and EuroQol visual analog scale (EQ-VAS)) and a clinical examination of hand function and imaging of circulatory efficiency. No significant changes were observed in the DASH, EQ-5D-5L, and EQ-VAS questionnaires. Clinical evaluation of hand function, measured by cold sensitivity, two-point discrimination, pain numerical analog scale, and grip strength also revealed no significant differences between cohorts. Blood flow measurements using thermal imaging revealed no effects on circulation in the affected digit. Collectively, the study finds reconstruction is not absolutely necessary when there is one intact digital artery as it is sufficient for healing and functional outcomes. We recommend finger artery reconstruction when both digital arteries are injured or if an immediate tension-free suture is possible

    Subcutaneous mastectomy in female-to-male transsexuals is associated with higher risk of postoperative bleeding complications

    No full text
    SUMMARY: Introduction: Chest contouring or subcutaneous mastectomy (SCM) in female-to-male (FtM) transgender individuals is the primary surgery in the gender reassignment process. Many authors report high rates of postoperative bleeding in these patients and discuss a possible influence of preoperative hormone therapy. However, there is a lack of data on the analysis between different surgical techniques and postoperative bleeding risk. Materials and Methods: In this retrospective study, we included 22 FtM transgender individuals who underwent bilateral SCM using 4 different techniques (44 breasts) between June 2014 and September 2023. Postoperative complications regarding surgical techniques and patient demographics were collected and analyzed. Results: SCM with free nipple grafting was the most commonly used technique (n = 12, 54.5%). The mean operative time was 163.4 ± 49.2 minutes. There were no significant differences in operative time between the surgical techniques (p ≥ 0.20 in all cases). The rate of acute postoperative bleeding was 20.5% (n = 9). Acute postoperative bleeding occurred most frequently in patients who received a semi-circular incision for SCM. There was no significant difference in the rate of acute postoperative bleeding between the different surgical techniques. BMI, breast weight, and duration of surgery were not associated with the rate of acute complications (p > 0.17 in all cases). Conclusions: Less invasive SCM techniques in FtM transgender individuals are associated with higher postoperative bleeding risk

    A New Standardized Clinical Model for Evaluation of Nerve Guides: A Single-Blinded Randomized Controlled Prospective Study.

    No full text
    BACKGROUND: Autologous nerve transplantation is the accepted clinical standard for reconstruction of peripheral nerve defects. Bioengineered nerve guides as an alternative to autologous nerve transplantation have been described in previous studies and several different types are commercially available. Examination of the implementation of these devices in the clinical setting is an important step in determining their applicability in reconstructive nerve surgery. METHODS: In a single-blinded randomized controlled prospective study, the authors examined 34 patients undergoing diagnostic nerve biopsy (2 cm). The biopsy-induced nerve gap was interposed using a segment of the lesser saphenous vein in 16 patients. Eighteen patients had no nerve reconstruction and served as a control group. A further 10 participants were included as a healthy cohort. Nerve regeneration was assessed using von Frey filaments preoperatively and 1 day and 3, 6, 9, and 12 months postoperatively. RESULTS: Patients who received defect bridging of the sural nerve with a venous graft showed better regeneration of lateral foot sensitivity than patients without venous graft. CONCLUSIONS: The distal sural nerve biopsy can be used as a baseline model to evaluate peripheral nerve regeneration. Newly developed nerve guides could be tested in other unpredictable and challenging clinical peripheral nerve lesions. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, II

    Factor XIII: More than just a fibrin stabilizer for the burn patient? A matched-pair analysis

    No full text
    Background: Acquired factor XIII deficiency is an underestimated risk in patients with large surface burns, which potentially exposes these patients to prolonged bleeding and delayed wound healing if undetected. Methods: A retrospective matched-pair analysis of the burn registry of the Department of Plastic, Aesthetic, Hand, and Reconstructive Surgery of Hannover Medical School was performed from 2018 to 2023. Results: A total of 18 patients were included. Acquired factor XIII deficiency was not statistically significant correlated with age, sex, or body mass index. Patients who developed acquired factor XIII deficiency had a significantly longer hospital stay (72.8 days) compared with those in the matched group (46.4 days), although burn depths, total body surface area, and Abbreviated Burn Severity Index were not statistically correlated with factor XIII deficiency. Conclusions: Little is known about acquired factor XIII deficiency in patients with burns. Factor XIII supplementation may improve hemostasis, wound healing, and general outcome while reducing the patient's exposure to blood products

    Implant-based multiplane breast augmentation—a personal surgical concept for dynamic implant–tissue interaction providing sustainable shape stability

    No full text
    <jats:title>Abstract</jats:title><jats:sec> <jats:title>Background</jats:title> <jats:p>The aesthetic long-term stability in shape, symmetry, and natural appearance of an aesthetically augmented breast remains a constant challenge. It has become clear that the results depend strongly on the technique applied and the experience of the surgeon. An ongoing controversy concerns the positioning of the implants. Subglandular, submuscular, partial submuscular, and subfascial pockets have different tradeoffs and advantages. However, secondary deformity, unnatural feel, and appearance are not addressed uniformly. The aim of the following study was to establish a standard procedure allowing for the desired and reproducible results to provide long-term stability and aesthetic quality.</jats:p> </jats:sec><jats:sec> <jats:title>Methods</jats:title> <jats:p>The authors have developed a standardized dissection of a dynamic implant pocket. In this approach, a submuscular dissection with lower and medial release of the pectoralis muscle is combined with a wide subfascial release of the breast gland and a scoring of the deep plane of the superficial glandular fascia. In the final step, the deep layer of the glandular fascia is sutured tightly and firmly to the deep layer of the abdomino-pectoral fascia. A total of 867 patients received a 4D pocket–based breast implant by the authors. A subset of 33 patients was further analyzed for long-term results. Retrospectively, all data were analyzed from the electronic patient information system and files of patients using GraphPad 8. For comparison of multiple experimental groups, one-way ANOVA was performed where indicated.</jats:p> </jats:sec><jats:sec> <jats:title>Results</jats:title> <jats:p>The concept not only addresses the biplanar approach of submuscular implant placement (3D) but adds the 4th dimension (4D) of an aesthetically pleasing dynamic shape of the augmented breast providing long-term stability. Measurements—taken at 3 months, and 1, 2, 3, 5, and ≥ 7 years post augmentation—for SN-N, N-IMF, N-ML, and MC-N distances did not show any significant changes over time. In the patient cohort of 867 patients (1734 implants), the overall complication rate was < 5%. Revisions for bleeding were below 0.5%. Shape stability was observed over 7 years in more than 95% of the patients.</jats:p> </jats:sec><jats:sec> <jats:title>Conclusions</jats:title> <jats:p>Our results indicate that our technique of multiplane breast augmentation provides long-term stability and aesthetic quality. It may solve some of the existing tradeoffs of the different methods by combining the benefits of each technique supported by an additional shaping through a controlled deep fasciotomy.</jats:p> <jats:p>Level of evidence: Level IV, therapeutic study.</jats:p> </jats:sec&gt

    In Vitro Differentiation of Myoblast Cell Lines on Spider Silk Scaffolds in a Rotating Bioreactor for Vascular Tissue Engineering

    No full text
    Functional construction of tissue-engineered vessels as an alternative to autologous vascular grafts has been shown to be feasible, however the proliferation of seeded smooth-muscle cells remains a limiting factor. We employed a rotating bioreactor system to improve myoblast cell differentiation on a spider silk scaffold for tissue-engineered vessel construction. C2C12 myofibroblast cells were seeded on the surface of spider silk scaffold constructs and cultivated in a rotating bioreactor system with a continuous rotation speed (1 rpm). Cell function, cell growth and morphological structure and expression of biomarkers were analyzed using scanning electron microscopy, the LIVE/DEAD® assay, Western blot and quantitative real-time PCR analyses. A dense myofibroblast cell sheet could be developed which resembled native blood vessel muscular tissue in morphological structure and in function. Bioreactor perfusion positively affected cell morphology, and increased cell viability and cell differentiation. The expression of desmin, MYF5 and MEF2D surged as an indication of myoblast differentiation. Cell-seeded scaffolds showed a tear-down at 18 N when strained at a set speed (20 mm min−1). Spider silk scaffolds appear to offer a reliable basis for engineered vascular constructs and rotating bioreactor cultivation may be considered an effective alternative to complex bioreactor setups to improve cell viability and biology

    The modified 5-item frailty index as a predictor of complications in burn patients

    No full text
    Summary: The modified 5-item frailty index (mFI-5), as a measure of frailty and biological age, has been shown to be a reliable predictor of complications and mortality in a variety of surgical specialties. However, its role in burn care remains to be fully elucidated. We, therefore, correlated frailty with in-hospital mortality and complications after burn injury. The medical charts of all burn patients admitted between 2007 and 2020 who had ≥ 10 % of their total body surface area affected were retrospectively reviewed. Data on clinical, demographic, and outcome parameters were collected and evaluated, and mFI-5 was calculated on the basis of the data obtained. Univariate and multivariate regression analyses were used to investigate the association between mFI-5 and medical complications and in-hospital mortality. A total of 617 burn patients were included in this study. Increasing mFI-5 scores were significantly associated with increased in-hospital mortality (p < 0.0001), myocardial infarction (p = 0.03), sepsis (p = 0.005), urinary tract infections (p = 0.006), and perioperative blood transfusions (p = 0.0004). They were also associated with an increase in the length of hospital stay and the number of surgical procedures, albeit without statistical significance. An mFI-5 score of ≥ 2 was a significant predictor of sepsis (odds ratio [OR] = 2.08; 95% confidence interval [CI]: 1.03 to 3.95; p = 0.04), urinary tract infection (OR = 2.82; 95% CI: 1.47 to 5.19; p = 0.002), and perioperative blood transfusions (OR = 2.61; 95% CI: 1.61 to 4.25; p = 0.0001). Multivariate logistic regression analysis revealed that an mFI-5 score of ≥ 2 was not an independent risk factor for in-hospital mortality (OR = 1.44; 95% CI: 0.61 to 3.37; p = 0.40). mFI-5 is a significant risk factor for only a few select complications in the burn population. It is not a reliable predictor of in-hospital mortality. Therefore, its utility as a risk stratification tool in the burn unit may be limited

    E-cigarette explosions: patient profiles, injury patterns, clinical management, and outcome

    No full text
    Background: E-cigarette abuse, also known as vaping, is a widespread habit. Recently, there have been increasing reports of explosions of these devices resulting in serious burn injuries, especially to the groin, hand, and face. Overheating rechargeable lithium-ion batteries are supposed to be the responsible mechanism, especially in low quality fabrications. Methods: In this single-center retrospective study, data of 46 patients are presented and analyzed. In addition to information on demographics, injury patterns, and treatment options, this is the first study investigating outcome after an average of 13 months via a standardized telephone interview of 31 patients (67%). Patients were specifically asked regarding their outcome, vaping habits, technical modifications to their devices and supply source. Results: Patients were mainly male (98.2%) with a median age of 36 years. Typical injury patterns included the groin region (n = 32; 69%), hands (n = 12; 25%) and face (n = 3; 7%). All patients underwent debridement, in nine cases hydrotherapeutically. 61% (n = 28) underwent consecutive tangential necrectomy and subsequent split thickness skin graft transplantation. Wound infection was observed in 18 patients (39%), with burn depth as a significant risk factor (p < 0.001). 91% of the followed-up patients were satisfied. Surprisingly, 38% were still using e-cigarettes. 42% (n = 13) reported manual modifications of their devices to prolong battery life or increasing smoke production. Conclusions: Injuries from exploding e-cigarettes can be serious and should be treated in a specialized burn center. E-cigarette explosions lead to characteristic injury patterns and often need surgical treatment. This should be made more public to reduce their use and keep people from modifying the devices. The counterintuitive and irrational observation of a high rate of abuse even after the injury underlines their addiction potential
    corecore