29 research outputs found

    Vascular access in COVID-19 patients: Smart decisions for maximal safety

    Get PDF
    : The 2020 COVID pandemic has forced everyone to update the usual medical procedures and adapt them to a new situation characterized by a high risk of contamination of the health operator. The placement of a venous access device is no exception. In the experience of the vascular access team of our hospital, hit by the COVID epidemic in March 2020, the safety of both the patient and the staff can be ensured by an insertion bundle of few smart strategies, which include choice of long dwelling peripheral catheters (midline catheters) rather than short venous cannulas; use of power injectable peripherally inserted central catheters in the COVID patients in intensive care unit requiring a central line; use of wireless probes-easy to carry, easy to clean-for ultrasound guided venipuncture; avoidance of x-rays, using alternative methods for tip location such as intracavitary electrocardiography or trans-thoracic echocardiography; strict adoption of the barrier precautions recommended by the international guidelines

    Continuous EEG monitoring by a new simplified wireless headset in intensive care unit

    Get PDF
    Background: In critically ill patients continuous EEG (cEEG) is recommended in several conditions. Recently, a new wireless EEG headset (CerebAir®,Nihon-Kohden) is available. It has 8 electrodes, and its positioning seems to be easier than conventional systems. Aim of this study was to evaluate the feasibility of this device for cEEG monitoring, if positioned by ICU physician. Methods: Neurological patients were divided in two groups according with the admission to Neuro-ICU (Study-group:20 patients) or General-ICU (Control-group:20 patients). In Study group, cEEG was recorded by CerebAir® assembled by an ICU physician, while in Control group a simplified 8-electrodes-EEG recording positioned by an EEG technician was performed. Results: Time for electrodes applying was shorter in Study-group than in Control-group: 6.2 ± 1.1' vs 10.4 ± 2.3'; p < 0.0001. Thirty five interventions were necessary to correct artifacts in Study-group and 11 in Control-group. EEG abnormalities with or without epileptic meaning were respectively 7(35%) and 7(35%) in Study-group, and 5(25%) and 9(45%) in Control-group;p > 0.05. In Study-group, cEEG was interrupted for risk of skin lesions in 4 cases after 52 ± 4 h. cEEG was obtained without EEG technician in all cases in Study-group; quality of EEG was similar. Conclusions: Although several limitations should be considered, this simplified EEG system could be feasible even if EEG technician was not present. It was faster to position if compared with standard techniques, and can be used for continuous EEG monitoring. It could be very useful as part of diagnostic process in an emergency setting

    Role of lung ultrasound for the etiological diagnosis of acute lower respiratory tract infection (ALRTI) in children: a prospective study

    Get PDF
    Objective and design: Our prospective study assesses the role of detailed lung ultrasound (LUS) features to discriminate the etiological diagnosis of acute lower respiratory tract infection (ALRTI) in children. Methodology: We analyzed patients aged from 1 month to 17 years admitted between March 2018 and April 2020 who were hospitalized for ALRTI. For all patients, history, clinical parameters, microbiological data, and lung ultrasound data were collected. Patients were stratified into three main groups ("bacterial", "viral", "atypical") according to the presumed microbial etiology and LUS findings evaluated according to the etiological group. Nasopharyngeal swabs were obtained from all patients. A qualitative diagnostic test developed by Nurex S.r.l. was used for identification of bacterial and fungal DNA in respiratory samples. The Seegene Allplex™ Respiratory assays were used for the molecular diagnosis of viral respiratory pathogens. In addition, bacterial culture of blood and respiratory samples were performed, when indicated. Results: A total of 186 children with suspected ALRTI (44% female) with an average age of 6 were enrolled in the study. We found that some ultrasound findings as size, number and distribution of consolidations, the position and motion of air bronchograms, pleural effusions and distribution of vertical artifacts significantly differ (p < 0.05) in children with bacterial, viral and atypical ALRTI. Conclusion: Our study provides a detailed analysis of LUS features able to predict the ALRTI ethology in children. These findings may help the physicians to better manage a child with ALRTI and to offer personalized approach, from diagnosis to treatment and follow-up

    Italian Society of Anesthesia, Analgesia, Resuscitation, and Intensive Care expert consensus statement on the use of lung ultrasound in critically ill patients with coronavirus disease 2019 (ITACO)

    Get PDF
    Background To produce statements based on the available evidence and an expert consensus (as members of the Lung Ultrasound Working Group of the Italian Society of Analgesia, Anesthesia, Resuscitation, and Intensive Care, SIAARTI) on the use of lung ultrasound for the management of patients with COVID-19 admitted to the intensive care unit. Methods A modified Delphi method was applied by a panel of anesthesiologists and intensive care physicians expert in the use of lung ultrasound in COVID-19 intensive critically ill patients to reach a consensus on ten clinical questions concerning the role of lung ultrasound in the following: COVID-19 diagnosis and monitoring (with and without invasive mechanical ventilation), positive end expiratory pressure titration, the use of prone position, the early diagnosis of pneumothorax- or ventilator-associated pneumonia, the process of weaning from invasive mechanical ventilation, and the need for radiologic chest imaging. Results A total of 20 statements were produced by the panel. Agreement was reached on 18 out of 20 statements (scoring 7–9; “appropriate”) in the first round of voting, while 2 statements required a second round for agreement to be reached. At the end of the two Delphi rounds, the median score for the 20 statements was 8.5 [IQR 8.9], and the agreement percentage was 100%. Conclusion The Lung Ultrasound Working Group of the Italian Society of Analgesia, Anesthesia, Resuscitation, and Intensive Care produced 20 consensus statements on the use of lung ultrasound in COVID-19 patients admitted to the ICU. This expert consensus strongly suggests integrating lung ultrasound findings in the clinical management of critically ill COVID-19 patients

    Diagnostic Accuracy of Procalcitonin in Bacterial Infections of the CNS: An Updated Systematic Review, Meta-Analysis, and Meta-Regression

    No full text
    Objectives: To evaluate diagnostic accuracy of serum and cerebrospinal fluid (CSF) procalcitonin for diagnosing CNS bacterial infections. Data sources: We searched MEDLINE, Cochrane Central Register of Controlled Trials, and International Web of Science databases from January 1, 2016, to September 30, 2022. Study selection: Randomized controlled trials and observational studies, either prospective or retrospective, focusing on procalcitonin as a biomarker for CNS infections. Data extraction: We screened and extracted studies independently and in duplicate. We assessed risk of bias using the revised Quality Assessment for Studies of Diagnostic Accuracy tool. Data for diagnostic sensitivity and specificity were pooled using the bivariate or hierarchical model, as appropriate. Data synthesis: Of 5,347 citations identified, 23 studies were included. Overall, CSF procalcitonin showed slightly higher pooled sensitivity, specificity, and positive likelihood ratio compared with serum procalcitonin. In adults, pooled sensitivity of CSF procalcitonin was 0.89 (95% CI, 0.71-0.96), specificity 0.81 (95% CI, 0.66-0.91); pooled sensitivity of serum procalcitonin was 0.82 (95% CI, 0.58-0.94), specificity 0.77 (95% CI, 0.60-0.89). In children, pooled sensitivity of CSF procalcitonin was 0.96 (95% CI, 0.88-0.99), specificity 0.91 (95% CI, 0.72-0.97); pooled sensitivity of serum procalcitonin was 0.90 (95% CI, 0.75-0.97), specificity 0.83 (95% CI, 0.67-0.92). In post-neurosurgical patients, pooled sensitivity of CSF procalcitonin was 0.82 (95% CI, 0.53-0.95), specificity 0.81 (95% CI, 0.63-0.91); pooled sensitivity of serum procalcitonin was 0.65 (95% CI, 0.33-0.88), specificity 0.61 (95% CI, 0.41-0.78). Logistic regression revealed between-study heterogeneity higher for serum than CSF procalcitonin. For the latter, threshold variability was found as source of heterogeneity. Conclusions: In children and critical post-neurosurgical patients, CSF procalcitonin gains superior sensitivity and specificity compared with serum procalcitonin. Overall, CSF procalcitonin appears to have a higher pooled positive likelihood ratio compared with serum procalcitonin

    Point-of-care ultrasound for non-vascular invasive procedures in critically ill neonates and children: current status and future perspectives

    No full text
    point-of-care ultrasound (POCUS) has been established as an essential bedside tool for real-time image guidance of invasive procedures in critically ill neonates and children. while procedural guidance using POCUS has become the standard of care across many adult medicine subspecialties, its use has more recently gained popularity in neonatal and pediatric medicine due in part to improvement in technology and integration of POCUS into physician training programs. with increasing use, emerging data have supported its adoption and shown improvement in pediatric outcomes. procedures that have traditionally relied on physical landmarks, such as thoracentesis and lumbar puncture, can now be performed under direct visualization using POCUS, increasing success, and reducing complications in our most vulnerable patients. In this review, we describe a global and comprehensive use of POCUS to assist all steps of different non-vascular invasive procedures and the evidence base to support such approach.conclusion: there has been a recent growth of supportive evidence for using point-of-care ultrasound to guide neonatal and pediatric percutaneous procedural interventions. a global and comprehensive approach for the use of point-of-care ultrasound allows to assist all steps of different, non-vascular, invasive procedures.What is Known:center dot Point-of-care ultrasound has been established as a powerful tool providing for real-time image guidance of invasive procedures in critically ill neonates and children and allowing to increase both safety and success.what is new:center dot a global and comprehensive use of point-of-care ultrasound allows to assist all steps of different, non-vascular, invasive procedures: from diagnosis to semi-quantitative assessment, and from real-time puncture to follow-up

    Point-of-care brain ultrasound and transcranial doppler or color-coded doppler in critically ill neonates and children

    No full text
    point-of-care brain ultrasound and transcranial doppler or color-coded doppler is being increasingly used as an essential diagnostic and monitoring tool at the bedside of critically ill neonates and children. Brain ultrasound has already established as a cornerstone of daily practice in the management of the critically ill newborn for diagnosis and follow-up of the most common brain diseases, considering the easiness to insonate the brain through transfontanellar window. In critically ill children, doppler based techniques are used to assess cerebral hemodynamics in acute brain injury and recommended for screening patients suffering from sickle cell disease at risk for stroke. However, more evidence is needed regarding the accuracy of doppler based techniques for non-invasive estimation of cerebral perfusion pressure and intracranial pressure, as well as regarding the accuracy of brain ultrasound for diagnosis and monitoring of acute brain parenchyma alterations in children. This review is aimed at providing a comprehensive overview for clinicians of the technical, anatomical, and physiological basics for brain ultrasonography and transcranial doppler or color-coded doppler, and of the current status and future perspectives of their clinical applications in critically ill neonates and children.Conclusion: In critically ill neonates, brain ultrasound for diagnosis and follow-up of the most common cerebral pathologies of the neonatal period may be considered the standard of care. Data are needed about the possible role of doppler techniques for the assessment of cerebral perfusion and vasoreactivity of the critically ill neonate with open fontanelles. In pediatric critical care, doppler based techniques should be routinely adopted to assess and monitor cerebral hemodynamics. New technologies and more evidence are needed to improve the accuracy of brain ultrasound for the assessment of brain parenchyma of critically ill children with fibrous fontanelles.what is known:center dot In critically ill neonates, brain ultrasound for early diagnosis and follow-up of the most common cerebral and neurovascular pathologies of the neonatal period is a cornerstone of daily practice. In critically ill children, doppler-based techniques are more routinely used to assess cerebral hemodynamics and autoregulation after acute brain injury and to screen patients at risk for vasospasm or stroke (e.g., sickle cell diseases, right-to-left shunts).What is New:center dot In critically ill neonates, research is currently focusing on the use of novel high frequency probes, even higher than 10 MHz, especially for extremely preterm babies. Furthermore, data are needed about the role of doppler based techniques for the assessment of cerebral perfusion and vasoreactivity of the critically ill neonate with open fontanelles, also integrated with a non-invasive assessment of brain oxygenation. In pediatric critical care, new technologies should be developed to improve the accuracy of brain ultrasound for the assessment of brain parenchyma of critically ill children with fibrous fontanelles. Furthermore, large multicenter studies are needed to clarify role and accuracy of doppler-based techniques to assess cerebral perfusion pressure and its changes after treatment interventions

    Clinically integrated ultrasound for decreasing the number of chest x-rays in the intensive care unit: It is high time to move forward a "global" use of ultrasound

    No full text
    ultrasound in intensive car

    Complications associated with the use of peripherally inserted central catheters and midline catheters in COVID-19 patients: An observational prospective study

    No full text
    Background: Among the many interesting aspects of clinical care during the SARS-CoV-2 pandemic, vascular access still deserves some attention. Peripherally inserted central catheters (PICCs) and midline catheters (MCs) are venous access devices inserted by ultrasound-guided puncture of veins of the arm, which have been associated with the possibility of minimizing infectious complications in different populations of patients. We have investigated their performance in SARS-CoV-2 patients. Methods: As the incidence of catheter-related bloodstream infections (CRBSI) in patients hospitalized for COVID-19 is still unclear, we have designed a single-center, prospective observational study enrolling all patients with established diagnosis of SARS-CoV-2 infection who were admitted to our hospital in the period between October 2020 and April 2021 and who required either a PICC or a MC. Results: We recruited 227 patients. The cumulative incidence of CRBSI was 4.35% (10 cases), that is, 3.5 episodes/1,000 catheter days. Four CRBSI occurred in patients with PICCs (4.5/1,000 catheter days) and 6 in those with MCs (3.2/1,000 catheter days). Conclusions: Our data suggest that COVID-19 patients may have a more pronounced tendency for the development of catheter-related infections compared to other populations of patients
    corecore