53 research outputs found

    Respiratory rate estimation from multi-channel signals using auto-regulated adaptive extended Kalman filter

    Get PDF
    Background: Respiration rate (RR) is a major cause for false alarms in intensive care units (ICU) and is primarily impaired by the artifact prone signals from skin-attached electrodes. Catheter-integrated esophageal electrodes are an alternative source for multi-channel physiological signals from multiple organs such as the heart and the diaphragm. Nonlinear estimation and sensor fusion are promising techniques for extracting the respiratory activity from such multi-component signals, however, pathologic breathing patterns with rapid RR changes typically observed in patient populations such as premature infants, pose significant challenges. Methods: We developed an auto-regulated adaptive extended Kalman filter (AA-EKF), which iteratively adapts the system model and the noise parameters based on the respiratory pattern. AA-EKF was tested on neonatal esophageal observations (NEO), and also on simulated multi-components signals created using waveforms in CapnoBase and ETNA databases. Results: AA-EKF derived RR (RRAA-EKF) from NEO had lower median (inter-quartile range) error of 0.1 (10.6) breaths per minute (bpm) compared to contemporary neonatal ICU monitors (RRNICU): −3.8 (15.7) bpm (p <0.001). RRAA-EKF error of −0.2 (3.2) bpm was achieved for ETNA wave forms and a bias (95% LOA) of 0.1 (−5.6, 5.9) in breath count. Mean absolute error (MAE) of RRAA-EKF with Capnobase waveforms, as median (inter-quartile range), at 0.3 (0.2) bpm was comparable to the literature reported values. Discussion: The auto-regulated approach allows RR estimation on a broad set of clinical data without requiring extensive patient specific adjustments. Causality and fast response times of EKF based algorithms makes the AA-EKF suitable for bedside monitoring in the ICU setting

    Is the Internal Rotation Lag Sign a Sensitive Test for Detecting Hip Abductor Tendon Ruptures after Total Hip Arthroplasty?

    Get PDF
    INTRODUCTION: Total hip arthroplasty (THA) is one of the most frequently performed procedures in orthopaedics and weakness of external rotators is often recognized thereafter. However, the etiology of lateral hip pain is multifaceted. For the diagnosis of abductor tendon rupture, magnetic resonance imaging (MRI) is the gold standard. As not every patient can be subjected to MRI, a clinical diagnostic test for easy detection of lesions of the abductor tendon is missing. Here, we present the internal rotation lack sign indicating abductor tendon pathology. METHODS: The patient is placed in lateral position on a stretcher with hips and knees in neutral position. The knee is flexed to 45° and the hip passively abducted and elevated by the investigator. With the foot passively abducted, the patient is then asked to bring his knee in direction to the examination table. This motion is also tested passively. The test is regarded positive, if no internal rotation is possible and/or if this is painful. If groin pain is elicited during either of the exercises, the test is also rated positive. RESULTS: We evaluated this test in 20 patients clinically and by magnetic resonance imaging (MRI). All patients demonstrated a positive internal rotation lag sign. Twelve of them lag of internal rotation and evidence of anterior abductor tendon rupture on MRI, 8 with lag of internal rotation and no evidence of abductor tendon rupture. CONCLUSION: The new clinical diagnostic sign presented here may improve the diagnosis of abductor tendon rupture in the future.Level of Evidence: Diagnostic study, level I

    Cement-augmented dorsal instrumentation of the spine as a safe adjunct to the multimodal management of metastatic pheochromocytoma: a case report

    Get PDF
    Malignant pheochromocytoma is a neuroendocrine tumor that originates from chromaffin tissue. Although osseous metastases are common, metastatic dissemination to the spine rarely occurs

    Mobile R-wave detection system powered by a thermoelectric generator

    Get PDF
    In modern medicine, monitoring devices for mobile application are using rechargeable power supplies. A new concept refers to energy scavenging techniques using heat emission from human body. This project deals with the development of a prototype and the feasibility study of a thermal harvester. A thermoelectric generator enables the device to work self-sufficient on temperature gradients between skin and ambient conditions. This developed energy harvesting system converts human body heat into electrical energy. In combination with ultra-lowpower components autonomous operation should be possible. The system should enable an R-wave detection circuitry. If the temperature gradient is high enough, there is supposed to be no lack of power as in case of ordinary battery systems. A system combining thermal energy harvesting and signal processing is developed. To show the functions of the energy harvester corresponding measurements are performed. The signal processing unit is set up but not evaluated in concrete measurements

    Cross-Talk between TLR4 and FcγReceptorIII (CD16) Pathways

    Get PDF
    Pathogen-pattern-recognition by Toll-like receptors (TLRs) and pathogen clearance after immune complex formation via engagement with Fc receptors (FcRs) represent central mechanisms that trigger the immune and inflammatory responses. In the present study, a linkage between TLR4 and FcγR was evaluated in vitro and in vivo. Most strikingly, in vitro activation of phagocytes by IgG immune complexes (IgGIC) resulted in an association of TLR4 with FcγRIII (CD16) based on co-immunoprecipitation analyses. Neutrophils and macrophages from TLR4 mutant (mut) mice were unresponsive to either lipopolysaccharide (LPS) or IgGIC in vitro, as determined by cytokine production. This phenomenon was accompanied by the inability to phosphorylate tyrosine residues within immunoreceptor tyrosine-based activation motifs (ITAMs) of the FcRγ-subunit. To transfer these findings in vivo, two different models of acute lung injury (ALI) induced by intratracheal administration of either LPS or IgGIC were employed. As expected, LPS-induced ALI was abolished in TLR4 mut and TLR4−/− mice. Unexpectedly, TLR4 mut and TLR4−/− mice were also resistant to development of ALI following IgGIC deposition in the lungs. In conclusion, our findings suggest that TLR4 and FcγRIII pathways are structurally and functionally connected at the receptor level and that TLR4 is indispensable for FcγRIII signaling via FcRγ-subunit activation

    Comparison of different techniques for prehospital cervical spine immobilization: Biomechanical measurements with a wireless motion capture system

    Get PDF
    Background Various rescue techniques are used for the prehospital transport of trauma patients. This study compares different techniques in terms of immobilization of the cervical spine and the rescue time. Methods A wireless motion capture system (Xsens Technologies, Enschede, The Netherlands) was used to record motion in three-dimensional space and the rescue time in a standardized environment. Immobilization was performed by applying different techniques through different teams of trained paramedics and physicians. All tests were performed on the set course, starting with the test person lying on the floor and ending with the test person lying on an ambulance cot ready to be loaded into an ambulance. Six different settings for rescue techniques were examined: rescue sheet with/without rigid cervical collar (P1S1, P1S0), vacuum mattress and scoop stretcher with/without rigid cervical collar (P2S1, P2S0), and long spinal board with/without rigid cervical collar (P3S1, P3S0). Four time intervals were defined: the time interval in which the rigid cervical collar is applied (T0), the time interval in which the test person is positioned on rescue sheet, vacuum mattress and scoop stretcher, or long spinal board (T1), the time interval in which the test person is carried to the ambulance cot (T2), and the time interval in which the ambulance cot is rolled to the ambulance (T3). An ANOVA was performed to compare the different techniques. Results During the simulated extrication procedures, a rigid cervical collar provided biomechanical stability at all angles with hardly any loss of time (mean angle ranges during T1: axial rotation P1S0 vs P1S1 p<0.0001, P2S0 vs P2S1 p<0.0001, P3S0 vs P3S1 p<0.0001; lateral bending P1S0 vs P1S1 p = 0.0263, P2S0 vs P2S1 p<0.0001, P3S0 vs P3S1 p<0.0001; flexion/extension P1S0 vs P1S1 p = 0.0023, P2S0 vs P2S1 p<0.0001). Of the three techniques examined, the scoop stretcher and vacuum mattress were best for reducing lateral bending in the frontal plane (mean angle ranges during T1: P2S1 vs P3S1 p = 0.0333; P2S0 vs P3S0 p = 0.0123) as well as flexion and extension in the sagittal plane (mean angle ranges during T2: P1S1 vs P2S1 p<0.0001; P1S0 vs P2S0 p<0.0001). On the other hand, the rescue sheet was clearly superior in terms of time (total duration P1S0 vs P2S0 p<0.001, P1S1 vs P2S1 p<0.001, P1S0 vs P3S0 p<0.001, P1S1 vs P3S1 p<0.001) but was always associated with significantly larger angular ranges of the cervical spine during the procedure. Therefore, the choice of technique depends on various factors such as the rescue time, the available personnel, as well as the severity of the suspected instability

    Prediction of grip and key pinch strength in 978 healthy subjects

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hand strength is an important independent surrogate parameter to assess outcome and risk of morbidity and mortality. This study aimed to determine the predictive power of cofactors and to predict population-based normative grip and pinch strength.</p> <p>Methods</p> <p>A representative population survey was used as the basis for prediction analyses (n = 978). Bivariate relationships between grip/pinch strengths of the dominate hand were explored by means of all relevant mathematical functions to maximize prediction. The resulting best functions were combined into a multivariate regression.</p> <p>Results</p> <p>Polynoms (up to the third degree) were the best predictive functions. On the bivariate level, height was best correlated to grip (46.2% explained variance) and pinch strength (37.7% explained variance) in a linear relationship, followed by sex, age, weight, and occupational demand on the hand. Multivariate regression provided predicted values close to the empirical ones explaining 76.6% of the variance for grip strength and 67.7% for pinch strength.</p> <p>Conclusion</p> <p>The five easy-to-measure cofactors sex, age, body height, categorized occupational demand on the hand, and body weight provide a highly accurate prediction of normative grip and pinch strength.</p

    The Methyl-CpG Binding Proteins Mecp2, Mbd2 and Kaiso Are Dispensable for Mouse Embryogenesis, but Play a Redundant Function in Neural Differentiation

    Get PDF
    The precise molecular changes that occur when a neural stem (NS) cell switches from a programme of self-renewal to commit towards a specific lineage are not currently well understood. However it is clear that control of gene expression plays an important role in this process. DNA methylation, a mark of transcriptionally silent chromatin, has similarly been shown to play important roles in neural cell fate commitment in vivo. While DNA methylation is known to play important roles in neural specification during embryonic development, no such role has been shown for any of the methyl-CpG binding proteins (Mecps) in mice.. No evidence for functional redundancy between these genes in embryonic development or in the derivation or maintenance of neural stem cells in culture was detectable. However evidence for a defect in neuronal commitment of triple knockout NS cells was found.Although DNA methylation is indispensable for mammalian embryonic development, we show that simultaneous deficiency of three methyl-CpG binding proteins genes is compatible with apparently normal mouse embryogenesis. Nevertheless, we provide genetic evidence for redundancy of function between methyl-CpG binding proteins in postnatal mice

    Characterization of a Drosophila Alzheimer's Disease Model: Pharmacological Rescue of Cognitive Defects

    Get PDF
    Transgenic models of Alzheimer's disease (AD) have made significant contributions to our understanding of AD pathogenesis, and are useful tools in the development of potential therapeutics. The fruit fly, Drosophila melanogaster, provides a genetically tractable, powerful system to study the biochemical, genetic, environmental, and behavioral aspects of complex human diseases, including AD. In an effort to model AD, we over-expressed human APP and BACE genes in the Drosophila central nervous system. Biochemical, neuroanatomical, and behavioral analyses indicate that these flies exhibit aspects of clinical AD neuropathology and symptomology. These include the generation of Aβ40 and Aβ42, the presence of amyloid aggregates, dramatic neuroanatomical changes, defects in motor reflex behavior, and defects in memory. In addition, these flies exhibit external morphological abnormalities. Treatment with a γ-secretase inhibitor suppressed these phenotypes. Further, all of these phenotypes are present within the first few days of adult fly life. Taken together these data demonstrate that this transgenic AD model can serve as a powerful tool for the identification of AD therapeutic interventions

    Biomechanical in vitro examination of a standardized low-volume tubular femoroplasty

    Full text link
    BACKGROUND Osteoporosis is associated with the risk of fractures near the hip. Age and comorbidities increase the perioperative risk. Due to the ageing population, fracture of the proximal femur also proves to be a socio-economic problem. Preventive surgical measures have hardly been used so far. METHODS 10 pairs of human femora from fresh cadavers were divided into control and low-volume femoroplasty groups and subjected to a Hayes fall-loading fracture test. The results of the respective localization and classification of the fracture site, the Singh index determined by computed tomography (CT) examination and the parameters in terms of fracture force, work to fracture and stiffness were evaluated statistically and with the finite element method. In addition, a finite element parametric study with different position angles and variants of the tubular geometry of the femoroplasty was performed. FINDINGS Compared to the control group, the work to fracture could be increased by 33.2%. The fracture force increased by 19.9%. The used technique and instrumentation proved to be standardized and reproducible with an average poly(methyl methacrylate) volume of 10.5 ml. The parametric study showed the best results for the selected angle and geometry. INTERPRETATION The cadaver studies demonstrated the biomechanical efficacy of the low-volume tubular femoroplasty. The numerical calculations confirmed the optimal choice of positioning as well as the inner and outer diameter of the tube in this setting. The standardized minimally invasive technique with the instruments developed for it could be used in further comparative studies to confirm the measured biomechanical results
    corecore