28 research outputs found

    Diesel Exhaust Inhalation Elicits Acute Vasoconstriction in Vivo

    Get PDF
    BACKGROUND: Traffic-related air pollution is consistently associated with cardiovascular morbidity and mortality. Recent human and animal studies suggest that exposure to air pollutants affects vascular function. Diesel exhaust (DE) is a major source of traffic-related air pollution. OBJECTIVES: Our goal was to study the effects of short-term exposure to DE on vascular reactivity and on mediators of vascular tone. METHODS: In a double-blind, crossover, controlled exposure study, 27 adult volunteers (10 healthy and 17 with metabolic syndrome) were exposed in randomized order to filtered air (FA) and each of two levels of diluted DE (100 or 200 μg/m3 of fine particulate matter) in 2-hr sessions. Before and after each exposure, we assessed the brachial artery diameter (BAd) by B-mode ultrasound and collected blood samples for endothelin-1 (ET-1) and catecholamines. Postexposure we also assessed endothelium-dependent flow-mediated dilation (FMD). RESULTS: Compared with FA, DE at 200 μg/m3 elicited a decrease in BAd (0.11 mm; 95% confidence interval, 0.02–0.18), and the effect appeared linearly dose related with a smaller effect at 100 μg/m3. Plasma levels of ET-1 increased after 200 μg/m3 DE but not after FA (p = 0.01). There was no consistent impact of DE on plasma catecholamines or FMD. CONCLUSIONS: These results demonstrate that short-term exposure to DE is associated with acute endothelial response and vasoconstriction of a conductance artery. Elucidation of the signaling pathways controlling vascular tone that underlie this observation requires further study

    Standardized ultrasound evaluation of carotid stenosis for clinical trials: University of Washington Ultrasound Reading Center

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Serial monitoring of patients participating in clinical trials of carotid artery therapy requires noninvasive precision methods that are inexpensive, safe and widely available. Noninvasive ultrasonic duplex Doppler velocimetry provides a precision method that can be used for recruitment qualification, pre-treatment classification and post treatment surveillance for remodeling and restenosis. The University of Washington Ultrasound Reading Center (UWURC) provides a uniform examination protocol and interpretation of duplex Doppler velocity measurements.</p> <p>Methods</p> <p>Doppler waveforms from 6 locations along the common carotid and internal carotid artery path to the brain plus the external carotid and vertebral arteries on each side using a Doppler examination angle of 60 degrees are evaluated. The UWURC verifies all measurements against the images and waveforms for the database, which includes pre-procedure, post-procedure and annual follow-up examinations. Doppler angle alignment errors greater than 3 degrees and Doppler velocity measurement errors greater than 0.05 m/s are corrected.</p> <p>Results</p> <p>Angle adjusted Doppler velocity measurements produce higher values when higher Doppler examination angles are used. The definition of peak systolic velocity varies between examiners when spectral broadening due to turbulence is present. Examples of measurements are shown.</p> <p>Discussion</p> <p>Although ultrasonic duplex Doppler methods are widely used in carotid artery diagnosis, there is disagreement about how the examinations should be performed and how the results should be validated. In clinical trails, a centralized reading center can unify the methods. Because the goals of research examinations are different from those of clinical examinations, screening and diagnostic clinical examinations may require fewer velocity measurements.</p

    Flow mediated dilation of the brachial artery: an investigation of methods requiring further standardization

    Get PDF
    BACKGROUND: In order to establish a consistent method for brachial artery reactivity assessment, we analyzed commonly used approaches to the test and their effects on the magnitude and time-course of flow mediated dilation (FMD), and on test variability and repeatability. As a popular and noninvasive assessment of endothelial function, several different approaches have been employed to measure brachial artery reactivity with B-mode ultrasound. Despite some efforts, there remains a lack of defined normal values and large variability in measurement technique. METHODS: Twenty-six healthy volunteers underwent repeated brachial artery diameter measurements by B-mode ultrasound. Following baseline diameter recordings we assessed endothelium-dependent flow mediated dilation by inflating a blood pressure cuff either on the upper arm (proximal) or on the forearm (distal). RESULTS: Thirty-seven measures were performed using proximal occlusion and 25 with distal occlusion. Following proximal occlusion relative to distal occlusion, FMD was larger (16.2 ± 1.2% vs. 7.3 ± 0.9%, p < 0.0001) and elongated (107.2 s vs. 67.8 s, p = 0.0001). Measurement of the test repeatability showed that differences between the repeated measures were greater on average when the measurements were done using the proximal method as compared to the distal method (2.4%; 95% CI 0.5–4.3; p = 0.013). CONCLUSION: These findings suggest that forearm compression holds statistical advantages over upper arm compression. Added to documented physiological and practical reasons, we propose that future studies should use forearm compression in the assessment of endothelial function

    Communication Biophysics

    Get PDF
    Contains reports on six research projects.National Institutes of Health (Grant 5 PO1 NS13126)National Institutes of Health (Grant 5 RO1 NS18682)National Institutes of Health (Grant 5 RO1 NS20322)National Institutes of Health (Grant 5 R01 NS20269)National Institutes of Health (Grant 5 T32NS 07047)Symbion, Inc.National Science Foundation (Grant BNS 83-19874)National Science Foundation (Grant BNS 83-19887)National Institutes of Health (Grant 6 RO1 NS 12846)National Institutes of Health (Grant 1 RO1 NS 21322

    Communications Biophysics

    Get PDF
    Contains reports on seven research projects split into three sections.National Institutes of Health (Grant 5 PO1 NS13126)National Institutes of Health (Grant 1 RO1 NS18682)National Institutes of Health (Training Grant 5 T32 NS07047)National Science Foundation (Grant BNS77-16861)National Institutes of Health (Grant 1 F33 NS07202-01)National Institutes of Health (Grant 5 RO1 NS10916)National Institutes of Health (Grant 5 RO1 NS12846)National Institutes of Health (Grant 1 RO1 NS16917)National Institutes of Health (Grant 1 RO1 NS14092-05)National Science Foundation (Grant BNS 77 21751)National Institutes of Health (Grant 5 R01 NS11080)National Institutes of Health (Grant GM-21189

    Communications Biophysics

    Get PDF
    Contains research objectives and reports on eight research projects split into three sections.National Institutes of Health (Grant 2 PO1 NS13126)National Institutes of Health (Grant 5 RO1 NS18682)National Institutes of Health (Grant 5 RO1 NS20322)National Institutes of Health (Grant 1 RO1 NS 20269)National Institutes of Health (Grant 5 T32 NS 07047)Symbion, Inc.National Institutes of Health (Grant 5 R01 NS10916)National Institutes of Health (Grant 1 RO NS 16917)National Science Foundation (Grant BNS83-19874)National Science Foundation (Grant BNS83-19887)National Institutes of Health (Grant 5 RO1 NS12846)National Institutes of Health (Grant 1 RO1 NS21322-01)National Institutes of Health (Grant 5 T32-NS07099-07)National Institutes of Health (Grant 1 RO1 NS14092-06)National Science Foundation (Grant BNS77-21751)National Institutes of Health (Grant 5 RO1 NS11080
    corecore