    Difference between the default telecoil (T-Coil) and programmed microphone frequency response in behind-the-ear (BTE) hearing aids

    Get PDF
    BACKGROUND: A telecoil (t-coil) is essential for hearing aid users when listening on the telephone because using the hearing aid microphone when communicating on the telephone can cause feedback due to telephone handset proximity to the hearing aid microphone. Clinicians may overlook the role of the t-coil due to a primary concern of matching the microphone frequency response to a valid prescriptive target. Little has been published to support the idea that the t-coil frequency response should match the microphone frequency response to provide “seamless” and perhaps optimal performance on the telephone. If the clinical goal were to match both frequency responses, it would be useful to know the relative differences, if any, which currently exist between these two transducers. PURPOSE: The primary purpose of this study was to determine if statistically significant differences were present between the mean output (in dB SPL) of the programmed microphone program and the hearing aid manufacturer’s default t-coil program as a function of discrete test frequencies. In addition, pilot data are presented on the feasibility of measuring the microphone and t-coil frequency response with real-ear measures using a digital speech-weighted noise. RESEARCH DESIGN: A repeated-measures design was utilized for a 2-cc coupler measurement condition. Independent variables were the transducer (microphone; t-coil), and eleven discrete test frequencies (fifteen discrete frequencies in the real-ear pilot condition). STUDY SAMPLE: The study sample was comprised of behind-the-ear (BTE) hearing aids from one manufacturer. Fifty-two hearing aids were measured in a coupler condition, 39 of which were measured in the real-ear pilot condition. Hearing aids were previously programmed and verified using real-ear measures to the NAL-NL1 prescriptive target by a licensed audiologist. DATA COLLECTION AND ANALYSIS: Hearing aid output was measured with a Fonix 7000 hearing aid analyzer (Frye Electronics, Inc.) in a HA-2 2-cc coupler condition using a pure-tone sweep at an input level of 60 dB SPL with the hearing aid in the microphone program and 31.6 mA/M in the t-coil program. A digital speech weighted noise input signal presented at additional input levels was used in the real-ear pilot condition. A mixed model repeated-measures Analysis of Variance (ANOVA) and the Tukey Honestly Significant Difference (HSD) post-hoc test were utilized to determine if significant differences were present in performance across treatment levels. RESULTS: There was no significant difference between mean overall t-coil and microphone output averaged across 11 discrete frequencies (F(1,102)=0, p<0.98). A mixed-model repeated measures ANOVA revealed a significant transducer by frequency interaction (F(10,102)=13.0, p<0.0001). Significant differences were present at 200 and 400 Hz where the mean t-coil output was less than the mean microphone output, and at 4000, 5000, and 6300 Hz where the mean t-coil output was greater than the mean microphone output. CONCLUSIONS: The mean t-coil output was significantly lower than the mean microphone output at 400 Hz, a frequency that lies within the typical telephone bandwidth of 300–3300 Hz. This difference may partially help to explain why some patients often complain the t-coil fails to provide sufficient loudness for telephone communication

    Difference between default telecoil and programmed microphone frequency response in behind-the-ear hearing aids

    Get PDF
    The notion that the default telecoil (t-coil) frequency response should match the programmed microphone frequency response to provide optimal telephone understanding for hearing aid patients has received little attention. This study addresses differences in the average frequency response of the two transducers in behind-the-ear (BTE) hearing aids

    Superconductor-to-Metal Transitions in Dissipative Chains of Mesoscopic Grains and Nanowires

    Get PDF
    The interplay of quantum fluctuations and dissipation in chains of mesoscopic superconducting grains is analyzed, and the results are also applied to nanowires. It is shown that in 1-d arrays of resistively shunted Josephson junctions, the superconducting-normal charge relaxation within the grains plays an important role. At zero temperature, two superconducting phases can exist, depending primarily on the strength of the dissipation. In the fully superconducting phase (FSC), each grain acts superconducting, and the coupling to the dissipative conduction is important. In the SC* phase, the dissipation is irrelevant at long wavelengths. The phase transitions between these two superconducting phases and the normal metallic phase may be either local or global, and possess rich and complex critical properties. These are inferred from both weak and strong coupling renormalization group analyses. At intermediate temperatures, near either superconductor-to-normal phase transition, there are regimes of super-metallic behavior, in which the resistivity first decreases gradually with decreasing temperature before eventually increasing as temperature is lowered further. The results on chains of Josephson junctions are extended to continuous superconducting nanowires and the subtle issue of whether these can exhibit an FSC phase is considered. Potential relevance to superconductor-metal transitions in other systems is also discussed.Comment: 42 pages, 14 figure

    Cognitive Load and Strategic Sophistication

    Full text link

    Dictator Games: A Meta Study

    Full text link
    corecore