9 research outputs found

    The Probable Effect of Irrigation Solution and Time on Bond Strength to Coronal Dentin: An In Vitro Evaluation

    Get PDF
    Introduction: The aim of this study was to evaluate the effect of root canal irrigants on the microtensile bond strength of 2-step self-etch adhesive to dentin. Methods and Materials: In this study 36 sound extracted human third molars were used. After grinding 3 mm of occlusal surface, teeth were randomly divided into 6 groups based on irrigation material naming normal saline, 5.25% sodium hypochlorite (NaOCl) and 2% chlorhexidine (CHX) and also irrigation time (5 or 30 min). Next, teeth were restored with Clearfil SE bond adhesive resin system and Z250 composite. The teeth were then thermo cycled by thermo cycling machine, for 500 cycles between 5º and 55ºC with 60 sec dwell time and 12 sec transfer time. All samples were sectioned into bucco-lingual slabs. The sections were submitted to the micro tensile testing machine at a crosshead speed of 0.5 mm/min until fracture. Data was analyzed using the one-way ANOVA test with the level of significance set at 0.05. Results: Irrigation with normal saline, 5.25% NaOCl and 2% CHX for 5 or 30 min did not significantly change the microtensile bond strength of adhesive to dentin (P=0.729 for time and P=0.153 for material). However the maximum and minimum microtensile bond strength was attributed to normal saline (44.13 N) and NaOCl (31.29 N) groups, respectively. Conclusion: Iirrigation solution and time have no influence on microtensile bond strength of two-step self-etch adhesive to coronal dentin.Keywords: Bond Strength, Dentin, Irrigation Solution

    Effect of Two Surface Sealants on Microleakage of Class V Resin Composite Restorations

    No full text
    Background and Aims: When composite resin polymerizes, shrinkage stresses tend to produce gaps at the tooth/ restoration interfaces. Surface sealants may reduce or avoid problems related to the marginal interface. The aim of this study was to evaluate the effect of two different surface sealants (Fortify and Optiguard) on the microleakage of class V resin composite restorations. Materials and Methods: Twenty three sound noncarious molars were collected. Totally, 45 Class V cavities with the occlusal margins in enamel and cervical margins in cementum were prepared in both buccal and lingual surfaces. The specimens were randomly assigned in three groups (15 cavities in each group) and then restored with a resin composite. After the finishing and polishing procedures, the restorations in each group were covered with a specific surface sealant, except for the control samples, which were not sealed. After placing restorations, the specimens were thermocycled and then immersed in a 50% silver nitrate solution (tracer agent) for four hours, sectioned longitudinally and analyzed for leakage using a stereomicroscope in a blind manner. The marginal microleakage was evaluated at the occlusal and cervical interfaces and compared among the three groups using the Kruskall-Wallis and the Mann-Whitney U tests. Results: Microleakage was found in all groups at both occlusal and cervical margins. Significantly greater leakage was observed at the cervical margins compared to the enamel margins of the material groups (P=0.005). There was no statistically significant difference among the groups at occlusal margins (P=0.66). In the cervical region, Fortify showed improved results and statistically presented the lowest degree of microleakage (P=0.003). onclusion: The used sealant materials presented different rates of effectiveness and Fortify decreased marginal microleakage significantly

    Invitro evaluation of the effect of some of the common carbonated beverages in Iran on the microhardness of two resin composites

    No full text
    Background and Aims: A suitable restorative material must have acceptable mechanical properties. The aim of this study was to evaluate the effect of conventional acidic drinks on the micro-hardness of two dental resins. Materials and Methods: 48 samples of each of P60 and G-aenial composites were prepared and randomly divided into six groups: Coca-Cola, Fanta, yoghurt drinks, soft beer, Sprites and control groups. The study was in 3 steps: after one day in distilled water and after one day and one week of immersion in beverages per day (6 hours). The Vickers micro-hardness was then evaluated. Finally, data were analyzed by, t-tests, ANOVA and Tukey tests. Resultes: Comparing the results between the two groups, a significant difference between the two composite was found. After one day in the water, the average micro-hardness for P60 was of 27.12 (kgf/mm2) and 16.51 (kgf/mm2) for G-aenial amount and these differences were found statistically significant (P=0.0001). For the 6-hour maintenance interval, the average micro-hardness between P60 and G-aenial was statistically significant (P=0.0001). For 42 hours, the average micro-hardness ranged between P60 and G-aenial that were statistically significant (P=0.0004). The stiffness of the P60 composite after 42 hours’ storage in soft beer significantly decreased compared with the control group (P=0.03). G-aenial composite hardness after 42 hours of soaking in the Coca-Cola was reduced significantly compared to yogurt drinks (P=0.02). Conclusion: As a result, the hardness of P60 composite was higher than that of G-aenial. The hardness of both composites reduced in acidic drinks after one week

    Effect of Curing Direction on Microtensile Bond Strength of Fifth and Sixth Generation Dental Adhesives

    No full text
    Background and Aims: Composite restorative materials and dental adhesives are usually cured with light sources. The light direction may influence the bond strength of dental adhesives. The aim of this study was to evaluate the effect of light direction on the microtensile bond strength of fifth and sixth generation dental adhesives.Materials and Methods: Prime & Bond NT and Clearfil SE bond were used with different light directions.Sixty human incisor teeth were divided into 4 groups (n=15). In groups A and C, Clearfil SE bond with light curing direction from buccal was used for bonding a composite resin to dentin. In groups B and D, Prime & Bond NT with light curing direction from composite was used. After thermocycling the specimens were subjected to tensile force until debonding occurred and values for microtensile bond strength were recorded. The data were analyzed using two-way ANOVA and Tukey post hoc test.Results: The findings showed that the bond strength of Clearfil SE bond was significantly higher than that of Prime&Bond NT (P<0.001). There was no significant difference between light curing directions (P=0.132).Conclusion: Light curing direction did not have significant effect on the bond strength. Sixth generation adhesives was more successful than fifth generation in terms of bond strength to dentin

    Comparison of solvent evaporation in the self etch and total etch adhesives in different air draying times

    No full text
      Background and Aims: Different adhesives with different solvents may have different solvent evaporation rates. The purpose of this study was to evaluate the solvent evaporation in the self etch and total etch adhesive in different air drying times.   Materials and Methods: Five adhesives were used in this study: Excite, Prime & Bond NT, UNO, Single Bond, SE Bond Primer. Twelve drops of each adhesive were used for each period of air drying (5, 15, 30 sec). The percentage of mass loss was measured during each test. Data were analized using two-way ANOVA and Tukey.   Results: Acetone base adhesives showed more loss of mass than other adhesives (P<0.01). P&B NT showed more loss of mass than other adhesives in all air drying times (P<0.01). Adhesives showed different evaporation rates in different air times (P<0.01).   Conclusion: Adhesives with acetone/water or alcohol/water solvent shows more stable behavior in comparison with adhesives containing pure aqueous solvents

    Effect of Re-Application of Microbrush on Micro Tensile Bond Strength of an Adhesive to Dentin

    No full text
    Background and Aims: Re-application of microbrush may affect the micro tensile bond strength of adhesives to dentin. The aim of this study was to evaluate the effect of re-application of microbrushes on the micro tensile bond strength of an adhesive to dentin.Materials and Methods: Thirty freshly extracted molars teeth were collected and enamel of occlusal surface were removed to expose superficial dentin. Then superficial dentin was etched, washed and partially air dried.According to the times of application of microbrush, teeth were divided into two test groups. In group 1, newmicrobrushs were used, but in group 2, the ones that were already used for twice were included. Ambar dentin bonding agent (FGM/Brazil) was applied to the etched dentin with microbrushes according to the manufacturer’s instructions. Then the crown of teeth was built up with LLiss (FGM/Brazil) composite resin. The teeth were sectioned in buccolingual direction to obtain 1mm slabs. Then 50 hourglass- shape samples were made from 30 teeth (25 Specimens per group). The microtensile bond strength of the specimens was tested using MTD500 (SD Mechatronik, Germany). The data were statistically analyzed by T-test.Results: The mean values for the microtensile bond strength were 30.49±7.18 and 23.61±9.06 MPa±SD for the first and second groups, respectively. There was significant difference between the groups (P=0.005).Conclusion: Microbrushes should not be used for more than one cavity preparation

    Comparison of shear bond strength of orthodontic brackets bonded with halogen and plasma arc light curing

    No full text
    Background: Reduced time and appropriate bond strength of brackets is one of the most important aspects of orthodontic treatments. Prolonged halogen light curing for bonding of brackets is undesirable, so the purpose of this study was to compare the shear bond strength of brackets bonded with halogen light and plasma arc system. Materials and Mehods: This was an experimental in vitro study. A total of 60 intact premolar teeth were collected and divided into four groups. Stainless steel orthodontic brackets were bonded to them. In groups 1 and 2, curing was done using halogen light given for 20 seconds from two and four angles. In groups 3 and 4, curing was carried out using the plasma arc system for 6 seconds from two and four angles. The shear bond strength was recorded by Instron. The statistics of ANOVA, Tukey′s test, and T-test were used in data analysis. Results: There was a statistically significant difference in shear bond strength among the four groups (P = 0.043) and between group 1 with group 2 (P = 0.035). Yet, there was no statistically significant difference between brackets bonded with plasma arc and those bonded with halogen light or between the two groups of plasma arc. Conclusion: Using the plasma arc system is superior to other methods due to reduced curing time. Also, since in using the halogen light system, an increase in curing periods from different angles resulted in a significant increase in shear bond strength; it is advisable to apply the halogen light from different angles

    Clinical Evaluation of the Effect of pH Values of Hydrogen Peroxide (35%) on the Ability of Whitening Teeth in Office Bleaching Technique

    No full text
    Introduction: Office bleaching is one of the conservative and common treatments for teeth discoloration. Because of increasing shelf life, most of the whitening gels contain a pH near 2 and that is below the critical level, which caused the enamel demineralization. The aim of this research was investigating the clinical study of changing the bleaching agent's pH for improving the color of discolored teeth. Methods: This clinical study was performed on 36 volunteer patients for bleaching. Patients were divided randomly into three groups. Patients received an office bleaching treatment sessions with 35% hydrogen peroxide at pH 8 and 10 and in the control group pH was 6.4. For changing the pH of bleaching agent, it was used 2.5 molar NaOH solutions. Color evaluation was performed in 2 maxillary central of patients with Easy Shade device (vita, Germany) before, immediately and one week after bleaching. Then, &nbsp;&Delta;E for each tooth according to the criteria a, b and l was calculated. Data were studied by Bundle SPSS20 and ANOVA Two-way statistical tests and multiple comparison of Tukey. Meanwhile, the 0.05 was considered statistically significant. Results: Changing of color before and after bleaching in each group was significantly different (p-value< 0/05), but pH between the groups has no statistically significant difference. Conclusion: Due to the limitations of this study, it seems that there is a similar effect in improving the color of teeth in three groups, soit is better to prevent the destruction of tooth enamel it is used the pH above the critical level of demineralizatio
    corecore