124 research outputs found

    Optical Properties of Deep Ice at the South Pole - Absorption

    Get PDF
    We discuss recent measurements of the wavelength-dependent absorption coefficients in deep South Pole ice. The method uses transit time distributions of pulses from a variable-frequency laser sent between emitters and receivers embedded in the ice. At depths of 800 to 1000 m scattering is dominated by residual air bubbles, whereas absorption occurs both in ice itself and in insoluble impurities. The absorption coefficient increases approximately exponentially with wavelength in the measured interval 410 to 610 nm. At the shortest wavelength our value is about a factor 20 below previous values obtained for laboratory ice and lake ice; with increasing wavelength the discrepancy with previous measurements decreases. At around 415 to 500 nm the experimental uncertainties are small enough for us to resolve an extrinsic contribution to absorption in ice: submicron dust particles contribute by an amount that increases with depth and corresponds well with the expected increase seen near the Last Glacial Maximum in Vostok and Dome C ice cores. The laser pulse method allows remote mapping of gross structure in dust concentration as a function of depth in glacial ice.Comment: 26 pages, LaTex, Accepted for publication in Applied Optics. 9 figures, not included, available on request from [email protected]

    The AMANDA Neutrino Telescope and the Indirect Search for Dark Matter

    Get PDF
    With an effective telescope area of order 10^4 m^2, a threshold of ~50 GeV and a pointing accuracy of 2.5 degrees, the AMANDA detector represents the first of a new generation of high energy neutrino telescopes, reaching a scale envisaged over 25 years ago. We describe its performance, focussing on the capability to detect halo dark matter particles via their annihilation into neutrinos.Comment: Latex2.09, 16 pages, uses epsf.sty to place 15 postscript figures. Talk presented at the 3rd International Symposium on Sources and Detection of Dark Matter in the Universe (DM98), Santa Monica, California, Feb. 199

    The AMANDA Neutrino Telescope: Principle of Operation and First Results

    Get PDF
    AMANDA is a high-energy neutrino telescope presently under construction at the geographical South Pole. In the Antarctic summer 1995/96, an array of 80 optical modules (OMs) arranged on 4 strings (AMANDA-B4) was deployed at depths between 1.5 and 2 km. In this paper we describe the design and performance of the AMANDA-B4 prototype, based on data collected between February and November 1996. Monte Carlo simulations of the detector response to down-going atmospheric muon tracks show that the global behavior of the detector is understood. We describe the data analysis method and present first results on atmospheric muon reconstruction and separation of neutrino candidates. The AMANDA array was upgraded with 216 OMs on 6 new strings in 1996/97 (AMANDA-B10), and 122 additional OMs on 3 strings in 1997/98.Comment: 36 pages, 23 figures, submitted to Astroparticle Physic

    The AMANDA Neutrino Telescope

    Full text link
    With an effective telescope area of order 10410^4 m2^2 for TeV neutrinos, a threshold near \sim50 GeV and a pointing accuracy of 2.5 degrees per muon track, the AMANDA detector represents the first of a new generation of high energy neutrino telescopes, reaching a scale envisaged over 25 years ago. We describe early results on the calibration of natural deep ice as a particle detector as well as on AMANDA's performance as a neutrino telescope.Comment: 12 pages, Latex2.09, uses espcrc2.sty and epsf.sty, 13 postscript files included. Talk presented at the 18th International Conference on Neutrino Physics and Astrophysics (Neutrino 98), Takayama, Japan, June 199

    Limits to the muon flux from WIMP annihilation in the center of the Earth with the AMANDA detector

    Full text link
    A search for nearly vertical up-going muon-neutrinos from neutralino annihilations in the center of the Earth has been performed with the AMANDA-B10 neutrino detector. The data sample collected in 130.1 days of live-time in 1997, ~10^9 events, has been analyzed for this search. No excess over the expected atmospheric neutrino background is oberved. An upper limit at 90% confidence level on the annihilation rate of neutralinos in the center of the Earth is obtained as a function of the neutralino mass in the range 100 GeV-5000 GeV, as well as the corresponding muon flux limit.Comment: 14 pages, 11 figures. Version accepted for publication in Physical Review

    UV and optical light transmission properties in deep ice at the South Pole

    Full text link
    Both absorption and scattering of light at wavelengths 410 to 610 nanometers were measured in the South Pole ice at depths 0.8 to 1 kilometer with the laser calibration system of the Antarctic Muon And Neutrino Detector Array (AMANDA). At the shortest wavelengths the absorption lengths exceeded 200 meters—an order of magnitude longer than has been reported for laboratory ice. The absorption shows a strong wavelength dependence while the scattering length is found to be independent of the wavelength, consistent with the hypothesis of a residual density of air bubbles in the ice. The observed linear decrease of the inverse scattering length with depth is compatible with an earlier measurement by the AMANDA collaboration (at ∼515 nanometers)

    Concomitant use of tamoxifen with radiotherapy enhances subcutaneous breast fibrosis in hypersensitive patients

    Get PDF
    Concomitant use of adjuvant tamoxifen (TAM) and radiation therapy (RT) is not widely accepted. We aim to assess whether this treatment is associated with an increased risk of developing subcutaneous fibrosis after conservative or radical surgery in breast cancer patients. We analysed 147 women with breast cancer treated with adjuvant RT, and who were included in the KFS 00539-9-1997/SKL 00778-2-1999 prospective study aimed at evaluating the predictive value of CD4 and CD8 T-lymphocyte apoptosis for the development of radiation-induced late effects. TAM (20 mg day(-1)) with concomitant RT was prescribed in 90 hormone receptor-positive patients. There was a statistically significant difference in terms of complication-relapse-free survival (CRFS) rates at 3 years, 48% (95% CI 37.2-57.6%) vs 66% (95% CI 49.9-78.6%) and complication-free survival (CFS) rates at 2 years, 51% (95% CI 40-61%) vs 80% (95% CI 67-89%) in the TAM and no-TAM groups, respectively. In each of these groups, the CRFS rates were significantly lower for patients with low levels of CD8 radiation-induced apoptosis, 20% (95% CI 10-31.9%), 66% (95% CI 51.1-77.6%), and 79% (95% CI 55-90.9%) for CD8 </=16, 16-24, and >24%, respectively. Similar results were observed for the CFS rates. The concomitant use of TAM with RT is significantly associated with an increased incidence of grade 2 or greater subcutaneous fibrosis; therefore, caution is needed for radiosensitive patients

    In vitro and in vivo MMP gene expression localisation by In Situ-RT-PCR in cell culture and paraffin embedded human breast cancer cell line xenografts

    Get PDF
    BACKGROUND: Members of the matrix metalloproteinase (MMP) family of proteases are required for the degradation of the basement membrane and extracellular matrix in both normal and pathological conditions. In vitro, MT1-MMP (MMP-14, membrane type-1-MMP) expression is higher in more invasive human breast cancer (HBC) cell lines, whilst in vivo its expression has been associated with the stroma surrounding breast tumours. MMP-1 (interstitial collagenase) has been associated with MDA-MB-231 invasion in vitro, while MMP-3 (stromelysin-1) has been localised around invasive cells of breast tumours in vivo. As MMPs are not stored intracellularly, the ability to localise their expression to their cells of origin is difficult. METHODS: We utilised the unique in situ-reverse transcription-polymerase chain reaction (IS-RT-PCR) methodology to localise the in vitro and in vivo gene expression of MT1-MMP, MMP-1 and MMP-3 in human breast cancer. In vitro, MMP induction was examined in the MDA-MB-231 and MCF-7 HBC cell lines following exposure to Concanavalin A (Con A). In vivo, we examined their expression in archival paraffin embedded xenografts derived from a range of HBC cell lines of varied invasive and metastatic potential. Mouse xenografts are heterogenous, containing neoplastic human parenchyma with mouse stroma and vasculature and provide a reproducible in vivo model system correlated to the human disease state. RESULTS: In vitro, exposure to Con A increased MT1-MMP gene expression in MDA-MB-231 cells and decreased MT1-MMP gene expression in MCF-7 cells. MMP-1 and MMP-3 gene expression remained unchanged in both cell lines. In vivo, stromal cells recruited into each xenograft demonstrated differences in localised levels of MMP gene expression. Specifically, MDA-MB-231, MDA-MB-435 and Hs578T HBC cell lines are able to influence MMP gene expression in the surrounding stroma. CONCLUSION: We have demonstrated the applicability and sensitivity of IS-RT-PCR for the examination of MMP gene expression both in vitro and in vivo. Induction of MMP gene expression in both the epithelial tumour cells and surrounding stromal cells is associated with increased metastatic potential. Our data demonstrate the contribution of the stroma to epithelial MMP gene expression, and highlight the complexity of the role of MMPs in the stromal-epithelial interactions within breast carcinoma

    Changing pattern of the detection of locoregional relapse in breast cancer: the Edinburgh experience

    Get PDF
    The guidelines for follow-up of breast cancer patients concentrate on the first 3–5 years, with either reduced frequency of visits or discharge after this. They also recommend mammography, but no evidence exists to inform frequency. We analyse treatable relapses in our unit from 1312 patients with early stage breast cancer treated by breast conserving surgery (BCS) and postoperative radiotherapy between 1991 and 1998 to assess appropriateness of the guidelines. A total of 110 treatable relapses were analysed. Treatable relapse developed at 1–1.5% per year throughout follow-up. Forty-eight relapses were in ipsilateral breast, 25 ipsilateral axilla, 35 contralateral breast, 2 both breasts simultaneously. Thirty-seven relapses (33.5%) were symptomatic, 56 (51%) mammographically detected, 15 (13.5%) clinically detected, 2 (2%) diagnosed incidentally. Mammography detected 5.37 relapses per 1000 mammograms. Patients with symptomatic or mammographically detected ipsilateral breast relapse had significantly longer survival from original diagnosis (P=0.0002) and from recurrence (P=0.0014) compared with clinically detected. Treatable relapse occurs at a constant rate for at least 10 years. Clinical examination detects a minority (13.5%). Relapse diagnosed clinically is associated with poorer outcome. Long-term follow-up based on regular mammography is warranted for all patients treated by BCS
    corecore