21,362 research outputs found
Disposable Integrated Microfluidic Biochip for Blood Typing by Plastic Microinjection Moulding
Blood typing is the most important test for both transfusion recipients and blood donors. In this paper, a low cost disposable blood typing integrated microfluidic biochip has been designed, fabricated and characterized. In the biochip, flow splitting microchannels, chaotic micromixers, reaction microchambers and detection microfilters are fully integrated. The loaded sample blood can be divided by 2 or 4 equal volumes through the flow splitting microchannel so that one can perform 2 or 4 blood agglutination tests in parallel. For the purpose of obtaining efficient reaction of agglutinogens on red blood cells (RBCs) and agglutinins in serum, we incorporated a serpentine laminating micromixer into the biochip, which combines two chaotic mixing mechanisms of splitting/recombination and chaotic advection. Relatively large area reaction microchambers were also introduced for the sake of keeping the mixture of the sample blood and serum during the reaction time before filtering. The gradually decreasing multi-step detection microfilters were designed in order to effectively filter the reacted agglutinated RBCs, which show the corresponding blood group. To achieve the cost-effectiveness of the microfluidic biochip for disposability, the biochip was realized by the microinjection moulding of COC (cyclic olefin copolymer) and thermal bonding of two injection moulded COC substrates in mass production with a total fabrication time of less than 20 min. Mould inserts of the biochip for the microinjection moulding were fabricated by SU-8 photolithography and the subsequent nickel electroplating process. Human blood groups of A, B and AB have been successfully determined with the naked eye, with 3 mu l of the whole sample bloods, by means of the fabricated biochip within 3 min.X11100104sciescopu
A serpentine laminating micromixer combining splitting/recombination and advection
Mixing enhancement has drawn great attention from designers of micromixers, since the flow in a microchannel is usually characterized by a low Reynolds number ( Re) which makes the mixing quite a difficult task to accomplish. In this paper, a novel integrated efficient micromixer named serpentine laminating micromixer (SLM) has been designed, simulated, fabricated and fully characterized. In the SLM, a high level of efficient mixing can be achieved by combining two general chaotic mixing mechanisms: splitting/recombination and chaotic advection. The splitting and recombination ( in other terms, lamination) mechanism is obtained by the successive arrangement of "F''-shape mixing units in two layers. The advection is induced by the overall three-dimensional serpentine path of the microchannel. The SLM was realized by SU-8 photolithography, nickel electroplating, injection molding and thermal bonding. Mixing performance of the SLM was fully characterized numerically and experimentally. The numerical mixing simulations show that the advection acts favorably to realize the ideal vertical lamination of fluid flow. The mixing experiments based on an average mixing color intensity change of phenolphthalein show a high level of mixing performance was obtained with the SLM. Numerical and experimental results confirm that efficient mixing is successfully achieved from the SLM over the wide range of Re. Due to the simple and mass producible geometry of the efficient micromixer, SLM proposed in this study, the SLM can be easily applied to integrated microfluidic systems, such as micro-total-analysis-systems or lab-on-a-chip systems.X11159165sciescopu
Recommended from our members
Meteorological and chemical factors controlling ozone formation in Seoul during MAPS-Seoul 2015
To understand the chemical mechanisms of controlling factors in ozone (O3) formation in early summer in Seoul, a comprehensive study encompassing measurement and modeling was conducted under the Megacity Air Pollution Study-Seoul (MAPS-Seoul) campaign. From May 18 to June 12, 2015, O3 and peroxyacetyl nitrate (PAN) were measured, along with their precursors, including NOx and volatile organic compounds (VOCs), at the Korea Institute of Science and Technology, located in northeast Seoul. VOCs were sampled in a canister twice a day (at 09:30 and 15:00) and analyzed via gas chromatography. The meteorological conditions and chemical regimes of the air masses were clearly distinguished during the study period. In May, NOx concentrations were higher with more pronounced diurnal cycles of precursors and O3 under constant westerly winds. By contrast, stagnant conditions developed in June, which reduced the inflow of primary emissions from the downtown area but increased the influence from the neighboring forest under high temperatures. As a result, the ratio of O3 to odd oxygen was higher in June, indicating a less efficient removal of O3 by NOx. In the same context, the air mass was chemically more aged with a higher NO2/NOx ratio and enhanced OH reactivity of oxygenated and biogenic VOCs in June. The overall measurement results suggest that O3 formation is slightly more sensitive to VOCs than to NOx in Seoul during this season, when O3 concentrations are the highest of the year
A Simple Approach to Characterize Gas-Aqueous Liquid Two-phase Flow Configuration Based on Discrete Solid-Liquid Contact Electrification
In this study, we first suggest a simple approach to characterize configuration of gas-aqueous liquid two-phase flow based on discrete solid-liquid contact electrification, which is a newly defined concept as a sequential process of solid-liquid contact and successive detachment of the contact liquid from the solid surface. This approach exhibits several advantages such as simple operation, precise measurement, and cost-effectiveness. By using electric potential that is spontaneously generated by discrete solid-liquid contact electrification, the configurations of the gas-aqueous liquid two-phase flow such as size of a gas slug and flow rate are precisely characterized. According to the experimental and numerical analyses on parameters that affect electric potential, gas slugs have been verified to behave similarly to point electric charges when the measuring point of the electric potential is far enough from the gas slug. In addition, the configuration of the gas-aqueous liquid two-phase microfluidic system with multiple gas slugs is also characterized by using the presented approach. For a proof-of-concept demonstration of using the proposed approach in a selftriggered sensor, a gas slug detector with a counter system is developed to show its practicality and applicability.1122Ysciescopu
Effect of Variable Selection Strategy on the Performance of Prognostic Models When Using Multiple Imputation
BACKGROUND: Variable selection is an important issue when developing
prognostic models. Missing data occur frequently in clinical research.
Multiple imputation is increasingly used to address the presence of
missing data in clinical research. The effect of different variable selection
strategies with multiply imputed data on the external performance of
derived prognostic models has not been well examined.
METHODS AND RESULTS: We used backward variable selection with
9 different ways to handle multiply imputed data in a derivation sample
to develop logistic regression models for predicting death within 1 year
of hospitalization with an acute myocardial infarction. We assessed
the prognostic accuracy of each derived model in a temporally distinct
validation sample. The derivation and validation samples consisted of
11524 patients hospitalized between 1999 and 2001 and 7889 patients
hospitalized between 2004 and 2005, respectively. We considered 41
candidate predictor variables. Missing data occurred frequently, with
only 13% of patients in the derivation sample and 31% of patients in the
validation sample having complete data. Regardless of the significance
level for variable selection, the prognostic model developed using only
the complete cases in the derivation sample had substantially worse
performance in the validation sample than did the models for which
variables were selected using the multiply imputed versions of the
derivation sample. The other 8 approaches to handling multiply imputed
data resulted in prognostic models with performance similar to one
another.
CONCLUSIONS: Ignoring missing data and using only subjects with
complete data can result in the derivation of prognostic models with poor
performance. Multiple imputation should be used to account for missing
data when developing prognostic models
Controlled release of human growth hormone fused with a human hybrid Fc fragment through a nanoporous polymer membrane
Nanotechnology has been applied to the development of more effective and compatible drug delivery systems for therapeutic proteins. Human growth hormone (hGH) was fused with a hybrid Fc fragment containing partial Fc domains of human IgD and IgG(4) to produce a long-acting fusion protein. The fusion protein, hGH-hyFc, resulted in the increase of the hydrodynamic diameter (ca. 11 nm) compared with the diameter (ca. 5 nm) of the recombinant hGH. A diblock copolymer membrane with nanopores (average diameter of 14.3 nm) exhibited a constant release rate of hGH-hyFc. The hGH-hyFc protein released in a controlled manner for one month was found to trigger the phosphorylation of Janus kinase 2 (JAK2) in human B lymphocyte and to exhibit an almost identical circular dichroism spectrum to that of the original hGH-hyFc, suggesting that the released fusion protein should maintain the functional and structural integrity of hGH. Thus, the nanoporous release device could be a potential delivery system for the long-term controlled release of therapeutic proteins fused with the hybrid Fc fragment.X111313sciescopu
Capacitive Control of Spontaneously Induced Electrical Charge of Droplet by Electric Field-Assisted Pipetting
The spontaneously generated electrical charge of a droplet dispensed from conventional pipetting is undesirable and unpredictable for most experiments that use pipetting. Hence, a method for controlling and removing the electrical charge needs to be developed. In this study, by using the electrode-deposited pipet tip (E-pipet tip), the charge-controlling system is newly developed and the electrical charge of a droplet is precisely controlled. The effect of electrolyte concentration and volume of the transferred solution to the electrical charge of a dispensed droplet is theoretically and experimentally investigated by using the equivalent capacitor model. Furthermore, a proof-of-concept example of the self-alignment and self-assembly of sequentially dispensed multiple droplets is demonstrated as one of the potential applications. Given that the electrical charge of the various aqueous droplets can be precisely and simply controlled, the fabricated E-pipet tip can be broadly utilized not only as a general charge-controlling platform of aqueous droplets but also as a powerful tool to explore fundamental scientific research regarding electrical charge of a droplet, such as the surface oscillation and evaporation of charged droplets.1143Ysciescopu
Origin of New Broad Raman D and G Peaks in Annealed Graphene
Since graphene, a single sheet of graphite, has all of its carbon atoms on the surface, its property is very sensitive to materials contacting the surface. Herein, we report novel Raman peaks observed in annealed graphene and elucidate their chemical origins by Raman spectroscopy and atomic force microscopy (AFM). Graphene annealed in oxygen-free atmosphere revealed very broad additional Raman peaks overlapping the D, G and 2D peaks of graphene itself. Based on the topographic confirmation by AFM, the new Raman peaks were attributed to amorphous carbon formed on the surface of graphene by carbonization of environmental hydrocarbons. While the carbonaceous layers were formed for a wide range of annealing temperature and time, they could be effectively removed by prolonged annealing in vacuum. This study underlines that spectral features of graphene and presumably other 2-dimensional materials are highly vulnerable to interference by foreign materials of molecular thickness.open116167Nsciescopu
Investigating the effect of thermal gradients on stress in solid oxide fuel cell anodes using combined synchrotron radiation and thermal imaging
Thermal gradients can arise within solid oxide fuel cells (SOFCs) due to start-up and shut-down, non-uniform gas distribution, fast cycling and operation under internal reforming conditions. Here, the effects of operationally relevant thermal gradients on Ni/YSZ SOFC anode half cells are investigated using combined synchrotron X-ray diffraction and thermal imaging. The combination of these techniques has identified significant deviation from linear thermal expansion behaviour in a sample exposed to a one dimensional thermal gradient. Stress gradients are identified along isothermal regions due to the presence of a proximate thermal gradient, with tensile stress deviations of up to 75Â MPa being observed across the sample at a constant temperature. Significant strain is also observed due to the presence of thermal gradients when compared to work carried out at isothermal conditions
- …