24 research outputs found

    Psychology and aggression

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/68264/2/10.1177_002200275900300301.pd

    In-situ determination of radionuclide levels in facilities to be decommissioned using the allowable residual contamination level method

    No full text
    This feasibility study resulted in verification of a direct and two alternate indirect techniques for making in-situ determinations of {sup 90}Sr and other radionuclide levels in a Hanford facility to be decommissioned that was evaluated using the Allowable Residual Contamination Level (ARCL) method. The ARCL method is used to determine the extent of decontamination that will be required before a facility can be decommissioned. A sump in the 1608F Building was chosen for the feasibility study. Hanford decommissioning personnel had previously taken 79 concrete and surface scale samples from the building to be analyzed by radiochemical analysis. The results of the radiochemical analyses compare favorably with the values derived by the in-situ methods presented in this report. Results obtained using a portable spectrometer and thermoluminescent dosimeters (TLDs) were both very close to the radiochemistry results. Surface {sup 90}Sr levels detected on the sump floor were 550 pCi/cm{sup 2} using the spectrometer system and 780 pCi/cm{sup 2} using the TLD data. This compares favorably with the levels determined by radiochemical analyses (i.e., 230 to 730 pCi/cm{sup 2}). Surface {sup 90}Sr levels detected on the sump wall ranged between 10 and 80 pCi/cm{sup 2} using the spectrometer system, compared with a conservative 200 pCi/cm{sup 2} using the TLD data. The radiochemical results ranged between 19 and 77 pCi/cm{sup 2} for the four samples taken from the wall at indeterminate locations. 17 refs., 15 figs., 2 tabs

    Evaluation of neutron dosimetry techniques for well-logging operations

    No full text
    Neutron dose and energy spectral measurements from /sup 241/AmBe and a 14 MeV neutron generator were performed at a well-logging laboratory. The measurement technique included the tissue equivalent proportional counter, multisphere, two types of remmeters and five types of personnel neutron dosimeters. Several source configurations were used to attempt to relate data to field situations. The results of the measurements indicated that the thermoluminescent albedo dosimeter was the most appropriate personnel neutron dosimeter, and that the most appropriate calibration source would be the source normally employed in the field with the calibration source being used in the unmoderated configuration. 7 refs., 35 figs., 14 tabs

    In-Flight Particle Measurements of Twin Wire Electric Arc Sprayed Aluminum

    No full text

    Passive immunity in cattle against enterotoxigenic Escherichia coli: serologic evaluation of a bacterin containing K99 and F41 fimbriae in colostrum of vaccinated females and calf serum Imunidade passiva contra Escherichia coli enterotoxigênica: avaliação sorológica de uma bacterina contendo as fímbrias K99 e F41 no colostro de fêmeas vacinadas e no soro de bezerros

    No full text
    A bacterin from enterotoxigenic Escherichia coli (ETEC), containing fimbriae K99 and F41, was produced and its capacity to induce anti-K99 and anti-F41 antibodies in colostrum of vaccinated cows and in calf serum, and the persistence of these antibodies in neonates were determined. Three experiments were performed on two commercial farms. In all experiments animals were allotted randomly to the blocks, each block consisting of two pregnant females (a vaccinated one and a control one) and their respective calves. In experiment A (farm 1), comprised of 18 blocks, the animals received a vaccine dose 30 days before delivery. In experiment B (farm 1), consisted of 26 blocks, the animals received two vaccine doses (60 and 30 days before delivery). In experiment C (farm 2), consisted of 22 blocks, the animals received two vaccine doses (60 and 30 days before delivery). In experiments A and B pregnant cows and heifers were used and colostrum and serum from 24- to 36-hour-old calves were collected. In experiment C, pregnant embryo-recipient heifers were used and colostrum and sera from calves at 7, 14, 28 and 42 days of age were collected. Anti-K99 and anti-F41 antibodies were detected by ELISA using purified K99 and F41 fimbrial antigens. In experiment A no difference between treated and control groups was observed for the concentration of anti-K99 and anti-F41 antibodies in colostrum and calf serum. In experiment B a difference (P<0.001) was observed for colostrum of vaccinated females and for serum of their calves. In experiment C, difference between vaccinated and control animals was observed for colostrum and calf serum at 7, 14, 28 (P<0.001 in all cases) and 42 days of age (P= 0.003). The results showed the efficiency of the bacterin to induce detectable humoral immune response.<br>Produziu-se uma bacterina de Escherichia coli enterotoxigênica (ETEC) contendo as fímbrias K99 e F41 e avaliaram-se a capacidade de indução de anticorpos anti-K99 e anti F-41 no colostro de vacas vacinadas e no soro de bezerros e a persistência dos anticorpos nos neonatos. Três experimentos foram realizados em duas fazendas comerciais. Os animais foram aleatoriamente alocados em blocos, de duas fêmeas prenhes (uma vacinada e outra controle) e seus respectivos bezerros. No experimento A (fazenda 1), com 18 blocos, os animais receberam uma dose da vacina, 30 dias antes do parto. No experimento B (fazenda 1), com 26 blocos, os animais receberam duas doses de vacina, aos 60 e 30 dias antes do parto. No experimento C (fazenda 2), com 22 blocos, os animais receberam o mesmo esquema de vacinação do experimento B. Nos experimentos A e B foram coletados colostro das parturientes e soro dos bezerros entre 24 e 36 horas de vida. No experimento C, foram usadas novilhas receptoras de embriões e coletados colostro e soro dos bezerros aos 7, 14, 28 e 42 dias de idade. Anticorpos anti-K99 e anti-F41 foram detectados por ELISA utilizando antígenos K99 e F41 purificados. No experimento A não foi observada diferença entre o grupo vacinado e o controle quanto à detecção de anticorpos. No experimento B foi observada diferença (P<0,001) entre o colostro de fêmeas vacinadas e o soro de seus bezerros. No C houve diferença entre o grupo vacinado e o controle para o colostro e o soro dos bezerros aos 7, 14, 28 (P<0,001) e 42 dias de idade (P= 0,003). A bacterina utilizada foi eficiente para a indução de resposta imune humoral detectável
    corecore