2 research outputs found

    АНАЛИЗ ДЕНСИТОМЕТРИЧЕСКИХ ПОКАЗАТЕЛЕЙ КОРОНАРНОГО РУСЛА ПРИ СТЕНОЗИРУЮЩИХ ПОРАЖЕНИЯХ КОРОНАРНЫХ АРТЕРИЙ И ПОСЛЕ ПРОЦЕДУРЫ СТЕНТИРОВАНИЯ МЕТОДОМ ОБЪЕМНОЙ МСКТ-КОРОНАРОГРАФИИ

    Get PDF
    The aim of this study was to evaluate the densitometric parameters of coronary arteries by volume MDCT coronary angiography for coronary artery stenosis and after percutaneous coronary stenting procedures. Volume MDCT coronary angiography was performed on 38 patients aged 47 to 75 years. The study was conducted on a 320-slice Aquilion One (Toshiba,Japan) computed tomographic machine, with prospective ECG-gating. The assessments of the results of stenting and coronary artery stenosis were determined density characteristics in Hounsfield units (HU) cross-sectional area of the vessel in the central departments, at a distance of5 mmproximal and distal to the stent or stenotic areas. In the absence of significant in-stent restenosis DI was >0,45, with a DI>< 0,8, with a DI< showed signs of significant in-stent restenosis. In the absence of significant stenosis of the vessel DI was >0,8, with a DI< 0,8 showed signs of significant stenosis or occlusion of the vessel. Thus, densitometric analysis with a volume MDCT coronary angiography can be used in the evaluation of coronary artery stenosis and in-stent restenosis for improving diagnostic informativity method. Volume scanning with prospective ECG-gating can significantly reduce the radiation exposure to the patient. Целью данного исследования являлся анализ денситометрических показателей коронарных артерий методом объемной многосрезовой компьютерно-томографической коронарографии (МСКТ-коронарографии) при стенозирующих и окклюзирующих поражениях коронарных артерий, а также после процедуры чрескожного коронарного стентирования. МСКТ-коронарография была выполнена 38 пациентам в возрасте от 47 до 75 лет. Исследование проводили на 320-срезовом компьютером томографе Aquilion One (Тошиба, Япония), в режиме объемного сканирования. При оценке результатов стентирования и стенозирующих поражений коронарных артерий были определены плотностные характеристики в единицах Хаунсфилда (ед. Х.) поперечного сечения сосуда в центральных отделах, на расстоянии5 ммпроксимальнее и дистальнее стентов либо зон стенозов и окклюзий. При отсутствии значимого внутристентового рестеноза значения денситометрического индекса (ДИ) были >0,45, при ДИ<0,45 выявлялись признаки значимого внутристентового рестеноза. Незначимый стеноз характеризовался значениями ДИ >0,8, при ДИ<0,8 были выявлены признаки значимого стеноза либо окклюзия сосуда. Таким образом, денситометрический анализ при объемной МСКТ-коронарографии может быть использован в оценке значимости стенозов коронарных артерий и внутристентовых рестенозов для повышения диагностической информативности метода. Объемное сканирование с проспективной ЭКГ-синхронизацией позволяет значительно снизить лучевую нагрузку на пациента.

    АНАЛИЗ ДЕНСИТОМЕТРИЧЕСКИХ ПОКАЗАТЕЛЕЙ КОРОНАРНОГО РУСЛА ПРИ СТЕНОЗИРУЮЩИХ ПОРАЖЕНИЯХ КОРОНАРНЫХ АРТЕРИЙ И ПОСЛЕ ПРОЦЕДУРЫ СТЕНТИРОВАНИЯ МЕТОДОМ ОБЪЕМНОЙ МСКТ-КОРОНАРОГРАФИИ

    No full text
    The aim of this study was to evaluate the densitometric parameters of coronary arteries by volume MDCT coronary angiography for coronary artery stenosis and after percutaneous coronary stenting procedures. Volume MDCT coronary angiography was performed on 38 patients aged 47 to 75 years. The study was conducted on a 320-slice Aquilion One (Toshiba,Japan) computed tomographic machine, with prospective ECG-gating. The assessments of the results of stenting and coronary artery stenosis were determined density characteristics in Hounsfield units (HU) cross-sectional area of the vessel in the central departments, at a distance of5 mmproximal and distal to the stent or stenotic areas. In the absence of significant in-stent restenosis DI was &gt;0,45, with a DI&gt;&lt; 0,8, with a DI&lt; showed signs of significant in-stent restenosis. In the absence of significant stenosis of the vessel DI was &gt;0,8, with a DI&lt; 0,8 showed signs of significant stenosis or occlusion of the vessel. Thus, densitometric analysis with a volume MDCT coronary angiography can be used in the evaluation of coronary artery stenosis and in-stent restenosis for improving diagnostic informativity method. Volume scanning with prospective ECG-gating can significantly reduce the radiation exposure to the patient. Целью данного исследования являлся анализ денситометрических показателей коронарных артерий методом объемной многосрезовой компьютерно-томографической коронарографии (МСКТ-коронарографии) при стенозирующих и окклюзирующих поражениях коронарных артерий, а также после процедуры чрескожного коронарного стентирования. МСКТ-коронарография была выполнена 38 пациентам в возрасте от 47 до 75 лет. Исследование проводили на 320-срезовом компьютером томографе Aquilion One (Тошиба, Япония), в режиме объемного сканирования. При оценке результатов стентирования и стенозирующих поражений коронарных артерий были определены плотностные характеристики в единицах Хаунсфилда (ед. Х.) поперечного сечения сосуда в центральных отделах, на расстоянии5 ммпроксимальнее и дистальнее стентов либо зон стенозов и окклюзий. При отсутствии значимого внутристентового рестеноза значения денситометрического индекса (ДИ) были &gt;0,45, при ДИ&lt;0,45 выявлялись признаки значимого внутристентового рестеноза. Незначимый стеноз характеризовался значениями ДИ &gt;0,8, при ДИ&lt;0,8 были выявлены признаки значимого стеноза либо окклюзия сосуда. Таким образом, денситометрический анализ при объемной МСКТ-коронарографии может быть использован в оценке значимости стенозов коронарных артерий и внутристентовых рестенозов для повышения диагностической информативности метода. Объемное сканирование с проспективной ЭКГ-синхронизацией позволяет значительно снизить лучевую нагрузку на пациента. </p
    corecore