3,724 research outputs found
Application of special-purpose digital computers to rotorcraft real-time simulation
The use of an array processor as a computational element in rotorcraft real-time simulation is studied. A multilooping scheme was considered in which the rotor would loop over its calculations a number of time while the remainder of the model cycled once on a host computer. To prove that such a method would realistically simulate rotorcraft, a FORTRAN program was constructed to emulate a typical host-array processor computing configuration. The multilooping of an expanded rotor model, which included appropriate kinematic equations, resulted in an accurate and stable simulation
A real-time, dual processor simulation of the rotor system research aircraft
A real-time, man-in-the loop, simulation of the rotor system research aircraft (RSRA) was conducted. The unique feature of this simulation was that two digital computers were used in parallel to solve the equations of the RSRA mathematical model. The design, development, and implementation of the simulation are documented. Program validation was discussed, and examples of data recordings are given. This simulation provided an important research tool for the RSRA project in terms of safe and cost-effective design analysis. In addition, valuable knowledge concerning parallel processing and a powerful simulation hardware and software system was gained
To identify the incidence, severity and timing of hypophosphataemia in Glasgow Royal Infirmary Intensive Care Unit (ICU) [poster]
No abstract available
The incidence, severity, timing and circadian variation of hypophosphataemia in Glasgow Royal Infirmary Intensive Care Unit [poster]
No abstract available
To identify the incidence, severity and timing of hypophosphataemia in Glasgow Royal Infirmary Intensive Care Unit (ICU) [poster]
No abstract available
A performance evaluation of commercial fibrinogen reference preparations and assays for Clauss and PT-derived fibrinogen
The wide availability of fibrinogen estimations based on the prothrombin time (PT-Fg) has caused concern about the variability and clinical utility of fibrinogen assays. In a multi-centre study, we investigated fibrinogen assays using various reagents and analysers, Clauss assays generally gave good agreement, although one reagent gave 15-30% higher values in DIC and thrombolysis. Two commercial reference preparations had much lower potencies than the manufacturers declared, and plasma turbidity influenced parallelism in some Clauss assays, PT-Fg assays gave higher values than Clauss and showed calibrant dependent effects, the degree of disparity correlating with calibrant and test sample turbidity. Analyser and thromboplastin dependent differences were noted. The relationship between Clauss and PT-Fg assays was sigmoid, and the plateau of maximal PT-Fg differed by about 2 g/l between reagents. ELISA and immunonephelometric assays correlated well, but with a high degree of scatter. Antigen levels were higher than Clauss, but slightly lower than PT-Fg assays, which appeared to be influenced by degraded fibrinogen. Clauss assays are generally reproducible between centres, analysers and reagents, but PT-Fg assays are not reliable in clinical settings
Superposition of macroscopic numbers of atoms and molecules
We theoretically examine photoassociation of a non-ideal Bose-Einstein
condensate, focusing on evidence for a macroscopic superposition of atoms and
molecules. This problem raises an interest because, rather than two states of a
given object, an atom-molecule system is a seemingly impossible macroscopic
superposition of different objects. Nevertheless, photoassociation enables
coherent intraparticle conversion, and we thereby propose a viable scheme for
creating a superposition of a macroscopic number of atoms with a macroscopic
number of molecules.Comment: 4 pages, 2 figs, to appear in Phys. Rev. Let
The incidence, severity, timing and circadian variation of hypophosphataemia in Glasgow Royal Infirmary Intensive Care Unit [poster]
No abstract available
- âŠ