16,579 research outputs found
Response time correlations for platinum resistance thermometers in flowing fluids
The thermal response of two types of Platinum Resistance Thermometers (PRT's), which are being considered for use in the National Transonic Wind Tunnel Facility, were studied. Response time correlations for each PRT, in flowing water, oil and air, were established separately. A universal correlation, tau WOA = 2.0 + 1264, 9/h, for a Hy-Cal Sensor (with a reference resistance of 100 ohm) within an error of 20% was established while the universal correlation for the Rosemount Sensor (with a reference resistance of 1000 ohm), tau OA = 0.122 + 1105.6/h, was found with a maximum percentage error of 30%. The correlation for the Rosemount Sensor was based on air and oil data only which is certainly not sufficient to make a correlation applicable to every condition. Therefore, the correlation needs more data to be gathered in different fluids. Also, it is necessary to state that the calculation of the parameter, h, was based on the available heat transfer correlations, whose accuracies are already reported in literature uncertain within 20-30%. Therefore, the universal response constant correlations established here for the Hy-Cal and Rosemount sensors are consistent with the uncertainty in the input data and are recommended for future use in flowing liquids and gases
Oscillating magnetoresistance due to fragile spin structure in metallic GdPd
Studies on the phenomenon of magnetoresistance (MR) have produced intriguing
and application-oriented outcomes for decades--colossal MR, giant MR and
recently discovered extremely large MR of millions of percents in semimetals
can be taken as examples. We report here the investigation of oscillating MR in
a cubic intermetallic compound GdPd, which is the only compound that
exhibits MR oscillations between positive and negative values. Our study shows
that a very strong correlation between magnetic, electrical and
magnetotransport properties is present in this compound. The magnetic structure
in GdPd is highly fragile since applied magnetic fields of moderate
strength significantly alter the spin arrangement within the system--a behavior
that manifests itself in the oscillating MR. Intriguing magnetotransport
characteristics of GdPd are appealing for field-sensitive device
applications, especially if the MR oscillation could materialize at higher
temperature by manipulating the magnetic interaction through perturbations
caused by chemical substitutions.Comment: 10 pages, 7 figures. A slightly modified version is published in
Scientific Report
- …