138 research outputs found
Tunnelling series in terms of perturbation theory for quantum spin systems
Considered is quantum tunnelling in anisotropic spin systems in a magnetic
field perpendicular to the anisotropy axis. In the domain of small field the
problem of calculating tunnelling splitting of energy levels is reduced to
constructing the perturbatio n series with degeneracy, the order of degeneracy
being proportional to a spin value. Partial summation of this series taking
into account ''dangerous terms'' with small denominators is performed and the
value of tunnelling splitting is calculated with allowance for the first
correction with respect to a magnetic field.Comment: 7 pages, REVTeX 3.
Level splittings in exchange-biased spin tunneling
The level splittings in a dimer with the antiferromagnetic coupling between
two single-molecule magnets are calculated perturbatively for arbitrary spin.
It is found that the exchange interaction between two single-molecule magnets
plays an important role in the level splitting. The results are discussed in
comparison with the recent experiment.Comment: 12 pages, to be published in Phys. Rev.
Quantum Phase Interference for Quantum Tunneling in Spin Systems
The point-particle-like Hamiltonian of a biaxial spin particle with external
magnetic field along the hard axis is obtained in terms of the potential field
description of spin systems with exact spin-coordinate correspondence. The
Zeeman energy term turns out to be an effective gauge potential which leads to
a nonintegrable pha se of the Euclidean Feynman propagator.
The phase interference between clockwise and anticlockwise under barrier
propagations is recognized explicitly as the Aharonov-Bohm effect. An
additional phase which is significant for quantum phase interference is
discovered with the quantum theory of spin systems besides the known phase
obtained with the semiclassical treatment of spin. We also show the energ y
dependence of the effect and obtain the tunneling splitting at excited states
with the help of periodic instantons.Comment: 19 pages, no figure, to appear in PR
Digital receivers for low-frequency radio telescopes UTR-2, URAN, GURT
This paper describes digital radio astronomical receivers used for decameter
and meter wavelength observations. This paper describes digital radio
astronomical receivers used for decameter and meter wavelength observations.
Since 1998, digital receivers performing on-the-fly dynamic spectrum
calculations or waveform data recording without data loss have been used at the
UTR-2 radio telescope, the URAN VLBI system, and the GURT new generation radio
telescope. Here we detail these receivers developed for operation in the strong
interference environment that prevails in the decameter wavelength range. Data
collected with these receivers allowed us to discover numerous radio
astronomical objects and phenomena at low frequencies, a summary of which is
also presented.Comment: 24 pages, 15 figure
Review of laser speckle contrast techniques for visualizing tissue perfusion
When a diffuse object is illuminated with coherent laser light, the backscattered light will form an interference pattern on the detector. This pattern of bright and dark areas is called a speckle pattern. When there is movement in the object, the speckle pattern will change over time. Laser speckle contrast techniques use this change in speckle pattern to visualize tissue perfusion. We present and review the contribution of laser speckle contrast techniques to the field of perfusion visualization and discuss the development of the techniques
Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters
Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\% to 5\%
Design, Performance, and Calibration of CMS Hadron-Barrel Calorimeter Wedges
Extensive measurements have been made with pions, electrons and muons on four production wedges of the Compact Muon Solenoid (CMS) hadron barrel (HB) calorimeter in the H2 beam line at CERN with particle momenta varying from 20 to 300 GeV/c. Data were taken both with and without a prototype electromagnetic lead tungstate crystal calorimeter (EB) in front of the hadron calorimeter. The time structure of the events was measured with the full chain of preproduction front-end electronics running at 34 MHz. Moving-wire radioactive source data were also collected for all scintillator layers in the HB. These measurements set the absolute calibration of the HB prior to first pp collisions to approximately 4%
Synchronization and Timing in CMS HCAL
The synchronization and timing of the hadron calorimeter (HCAL) for the Compact Muon Solenoid has been extensively studied with test beams at CERN during the period 2003-4, including runs with 40 MHz structured beam. The relative phases of the signals from different calorimeter segments are timed to 1 ns accuracy using a laser and equalized using programmable delay settings in the front-end electronics. The beam was used to verify the timing and to map out the entire range of pulse shapes over the 25 ns interval between beam crossings. These data were used to make detailed measurements of energy-dependent time slewing effects and to tune the electronics for optimal performance
Design, Performance, and Calibration of the CMS Hadron-Outer Calorimeter
The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with an outer calorimeter to ensure high energy shower containment in the calorimeter. Fabrication, testing and calibration of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing \et measurements at LHC energies. The outer hadron calorimeter will also be used for the muon trigger in coincidence with other muon chambers in CMS
- …