1,055 research outputs found

    Influence of the heterointerface sharpness on exciton recombination dynamics in an ensemble of (In,Al)As/AlAs quantum dots with indirect band-gap

    Full text link
    The dynamics of exciton recombination in an ensemble of indirect band-gap (In,Al)As/AlAs quantum dots with type-I band alignment is studied. The lifetime of confined excitons which are indirect in momentum-space is mainly influenced by the sharpness of the heterointerface between the (In,Al)As quantum dot and the AlAs barrier matrix. Time-resolved photoluminescence experiments and theoretical model calculations reveal a strong dependence of the exciton lifetime on the thickness of the interface diffusion layer. The lifetime of excitons with a particular optical transition energy varies because this energy is obtained for quantum dots differing in size, shape and composition. The different exciton lifetimes, which result in photoluminescence with non-exponential decay obeying a power-law function, can be described by a phenomenological distribution function, which allows one to explain the photoluminescence decay with one fitting parameter only.Comment: 10 pages, 7 figure

    Spin dynamics and magnetic-field-induced polarization of excitons in ultrathin GaAs/AlAs quantum wells with indirect band gap and type-II band alignment

    Full text link
    The exciton spin dynamics are investigated both experimentally and theoretically in two-monolayer-thick GaAs/AlAs quantum wells with an indirect band gap and a type-II band alignment. The magnetic-field-induced circular polarization of photoluminescence, PcP_c, is studied as function of the magnetic field strength and direction as well as sample temperature. The observed nonmonotonic behaviour of these functions is provided by the interplay of bright and dark exciton states contributing to the emission. To interpret the experiment, we have developed a kinetic master equation model which accounts for the dynamics of the spin states in this exciton quartet, radiative and nonradiative recombination processes, and redistribution of excitons between these states as result of spin relaxation. The model offers quantitative agreement with experiment and allows us to evaluate, for the studied structure, the heavy-hole gg factor, ghh=+3.5g_{hh}=+3.5, and the spin relaxation times of electron, τse=33 μ\tau_{se} = 33~\mus, and hole, τsh=3 μ\tau_{sh} = 3~\mus, bound in the exciton.Comment: 17 pages, 16 figure

    Carbon Ion irradiation in the treatment of grossly incomplete or unresectable malignant peripheral nerve sheaths tumors: acute toxicity and preliminary outcome

    Get PDF
    Background: To report our early experience with carbon ion irradiation in the treatment of gross residual or unresectable malignant peripheral nerve sheath tumors (MPNST). Methods: We retrospectively analysed 11 patients (pts) with MPNST, who have been treated with carbon ion irradiation (C12) at our institution between 2010 and 2013. All pts had measurable gross disease at the initiation of radiation treatment. Median age was 47 years (29-79). Tumors were mainly located in the pelvic/sacral (5 pts) and sinunasal/orbital region (5 pts). 5 pts presented already in recurrent situation, 3 pts had been previously irradiated, and in 3 pts MPNST were neurofibromatosis type 1 (NF1) associated. Median cumulative dose was 60 GyE. Treatment was carried out either as a combination of IMRT plus C12 boost (4 pts) or C12 only (7 pts). Results: Median follow-up was 17 months (3-31 months). We observed 3 local progressions, translating into estimated 1- and 2-year local control rates of 65%. One patient developed distant failure, resulting in estimated 1- and 2-year PFS rates of 56%. Two patients have died, therefore the estimated 1- and 2-year OS rates are 75%. Acute radiation related toxicities were generally mild, no grade 3 side effects were observed. Severe late toxicity (grade 3) was scored in 2 patients (trismus, wound healing delays). Conclusion: Carbon ion irradiation yields very promising short term local control and overall survival rates with low morbidity in patients suffering from gross residual or unresectable malignant peripheral nerve sheath tumors and should be further investigated in a prospective trial

    Treatment of malignant sinonasal tumours with intensity-modulated radiotherapy (IMRT) and carbon ion boost (C12)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Most patients with cancers of the nasal cavity or paranasal sinuses are candidates of radiation therapy either due incomplete resection or technical inoperability. Local control in this disease is dose dependent but technically challenging due to close proximity of critical organs and accompanying toxicity. Modern techniques such as IMRT improve toxicity rates while local control remains unchanged. Raster-scanned carbon ion therapy with highly conformal dose distributions may allow higher doses at comparable or reduced side-effects.</p> <p>Methods/design</p> <p>The IMRT-HIT-SNT trial is a prospective, mono-centric, phase II trial evaluating toxicity (primary endpoint: mucositis ≥ CTCAE°III) and efficacy (secondary endpoint: local control, disease-free and overall survival) in the combined treatment with IMRT and carbon ion boost in 30 patients with histologically proven (≥R1-resected or inoperable) adeno-/or squamous cell carcinoma of the nasal cavity or paransal sinuses. Patients receive 24 GyE carbon ions (8 fractions) and IMRT (50 Gy at 2.0 Gy/fraction).</p> <p>Discussion</p> <p>The primary objective of IMRT-HIT-SNT is to evaluate toxicity and feasibility of the proposed treatment in sinonasal malignancies.</p> <p>Trial Registration</p> <p>Clinical trial identifier <a href="http://www.clinicaltrials.gov/ct2/show/NCT01220752">NCT 01220752</a></p

    Spin diffusion in the Mn2+ ion system of II-VI diluted magnetic semiconductor heterostructures

    Full text link
    The magnetization dynamics in diluted magnetic semiconductor heterostructures based on (Zn,Mn)Se and (Cd,Mn)Te has been studied experimentally by optical methods and simulated numerically. In the samples with nonhomogeneous magnetic ion distribution this dynamics is contributed by spin-lattice relaxation and spin diffusion in the Mn spin system. The spin diffusion coefficient of 7x10^(-8) cm^2/s has been evaluated for Zn(0.99)Mn(0.01)Se from comparison of experimental and numerical results. Calculations of the giant Zeeman splitting of the exciton states and the magnetization dynamics in the ordered alloys and parabolic quantum wells fabricated by the digital growth technique show perfect agreement with the experimental data. In both structure types the spin diffusion has an essential contribution to the magnetization dynamics.Comment: 12 pages, 11 figure
    corecore