991 research outputs found

    Zero Field precession and hysteretic threshold currents in spin torque oscillators with tilted polarizer

    Full text link
    Using non-linear system theory and numerical simulations we map out the static and dynamic phase diagram in zero applied field of a spin torque oscillator with a tilted polarizer (TP-STO).We find that for sufficiently large currents, even very small tilt angles (beta>1 degree) will lead to steady free layer precession in zero field. Within a rather large range of tilt angles, 1 degree< beta <19 degree, we find coexisting static states and hysteretic switching between these using only current. In a more narrow window (1 degree<beta<5 degree) one of the static states turns into a limit cycle (precession). The coexistence of static and dynamic states in zero magnetic field is unique to the tilted polarizer and leads to large hysteresis in the upper and lower threshold currents for TP-STO operation.Comment: 5 pages, 4 figure

    In Vivo Spike-Timing-Dependent Plasticity in the Optic Tectum of Xenopus Laevis

    Get PDF
    Spike-timing-dependent plasticity (STDP) is found in vivo in a variety of systems and species, but the first demonstrations of in vivo STDP were carried out in the optic tectum of Xenopus laevis embryos. Since then, the optic tectum has served as an excellent experimental model for studying STDP in sensory systems, allowing researchers to probe the developmental consequences of this form of synaptic plasticity during early development. In this review, we will describe what is known about the role of STDP in shaping feed-forward and recurrent circuits in the optic tectum with a focus on the functional implications for vision. We will discuss both the similarities and differences between the optic tectum and mammalian sensory systems that are relevant to STDP. Finally, we will highlight the unique properties of the embryonic tectum that make it an important system for researchers who are interested in how STDP contributes to activity-dependent development of sensory computations

    Minimal effects of waterborne exposure to single-walled carbon nanotubes on behaviour and physiology of juvenile rainbow trout (Oncorhynchus mykiss).

    Get PDF
    Fish behaviours are often considered to be sensitive endpoints of waterborne contaminants, but little attention has been given to engineered nanomaterials. The present study aimed to determine the locomotor and social behaviours of rainbow trout (Oncorhynchus mykiss) during waterborne exposure to single-walled carbon nanotubes (SWCNTs), and to ascertain the physiological basis for any observed effects. Dispersed stock suspensions of SWCNTs were prepared by stirring in sodium dodecyl sulphate (SDS), an anionic surfactant, on an equal w/w basis. Trout were exposed to control (no SWCNT or SDS), 0.25 mg L(-1) SDS (dispersant control), or 0.25 mg L(-1) of SWCNT for 10 days. Video tracking analysis of spontaneous locomotion of individual fish revealed no significant effects of SWCNT on mean velocity when active, total distance moved, or the distribution of swimming speeds. Hepatic glycogen levels were also unaffected. Fish exposed to SWCNTs retained competitive fitness when compelled to compete in energetically costly aggressive interactions with fish from both control groups. Assessment of the respiratory physiology of the fish revealed no significant changes in ventilation rate or gill injuries. Haematocrit and haemoglobin concentrations in the blood were unaffected by SWCNT exposure; and the absence of changes in the red and white pulp of the spleen excluded a compensatory haematopoietic response to protect the circulation. Despite some minor histological changes in the kidneys of fish exposed to SWCNT compared to controls, plasma ion concentrations and tissue electrolytes were largely unaffected. Direct neurotoxicity of SWCNT was unlikely with the brains showing mostly normal histology, and with no effects on acetylcholinesterase or Na(+)/K(+)-ATPase activities in whole brain homogenates. The minimal effects of waterborne exposure to SWCNT observed in this study are in contrast to our previous report of SWCNT toxicity in trout, suggesting that details of the dispersion method and co-exposure concentration of the dispersing agent may alter toxicity

    Quantum control of 88^{88}Sr+^+ in a miniature linear Paul trap

    Full text link
    We report on the construction and characterization of an apparatus for quantum information experiments using 88^{88}Sr+^+ ions. A miniature linear radio-frequency (rf) Paul trap was designed and built. Trap frequencies above 1 MHz in all directions are obtained with 50 V on the trap end-caps and less than 1 W of rf power. We encode a quantum bit (qubit) in the two spin states of the S1/2S_{1/2} electronic ground-state of the ion. We constructed all the necessary laser sources for laser cooling and full coherent manipulation of the ions' external and internal states. Oscillating magnetic fields are used for coherent spin rotations. High-fidelity readout as well as a coherence time of 2.5 ms are demonstrated. Following resolved sideband cooling the average axial vibrational quanta of a single trapped ion is nˉ=0.05\bar n=0.05 and a heating rate of nˉ˙=0.016\dot{\bar n}=0.016 ms1^{-1} is measured.Comment: 8 pages,9 figure

    Enteroscopic Balloon Dilation of Multiple Ileal Strictures in Suspected Crohn's Disease

    Get PDF
    AbstractWith the advent of small bowel enteroscopy, the limits to the endoscopic access to the small bowel have been further exceeded, allowing histology sampling and therapeutical maneuvers. This conquest is of crucial meaning in small bowel inflammatory diseases. In this setting, enteroscopy may lead to a definite diagnosis, overcoming the limits of the anatomic disease location and of other (radiological and endoscopic imaging) techniques. Furthermore, enteroscopy permits strictures visualization and dilation, reducing or postponing the need for surgery. In this article the authors demonstrate the technique of hydrostatic balloon dilation of small bowel strictures suggestive of Crohn's disease in a patient suffering from persistent obscure gastrointestinal bleeding. This article is part of an expert video encyclopedia

    Are ancient dwarf satellites the building blocks of the Galactic halo?

    Get PDF
    This article has been accepted for publication in Monthly Notices of the Royal Astronomical Society. ©: 2016 The Author(s). Published by Oxford University Press on behalf of the Royal Astronomical Society. All rights reserved.According to the current cosmological cold dark matter paradigm, the Galactic halo could have been the result of the assemblage of smaller structures. Here we explore the hypothesis that the classical and ultra-faint dwarf spheroidal satellites of the Milky Way have been the building blocks of the Galactic halo by comparing their [α/Fe] and [Ba/Fe] versus [Fe/H] patterns with the ones observed in Galactic halo stars. The α elements deviate substantially from the observed abundances in the Galactic halo stars for [Fe/H] values larger than −2 dex, while they overlap for lower metallicities. On the other hand, for the [Ba/Fe] ratio, the discrepancy is extended at all [Fe/H] values, suggesting that the majority of stars in the halo are likely to have been formed in situ. Therefore, we suggest that [Ba/Fe] ratios are a better diagnostic than [α/Fe] ratios. Moreover, for the first time we consider the effects of an enriched infall of gas with the same chemical abundances as the matter ejected and/or stripped from dwarf satellites of the Milky Way on the chemical evolution of the Galactic halo. We find that the resulting chemical abundances of the halo stars depend on the assumed infall time-scale, and the presence of a threshold in the gas for star formation. In particular, in models with an infall time-scale for the halo around 0.8 Gyr coupled with a threshold in the surface gas density for the star formation (4 M pc−2), and the enriched infall from dwarf spheroidal satellites, the first halo stars formed show [Fe/H]>−2.4 dex. In this case, to explain [α/Fe] data for stars with [Fe/H]<−2.4 dex, we need stars formed in dSph systems.Peer reviewedFinal Published versio

    Flow cytometric S-phase fraction in soft-tissue sarcoma: prognostic importance analysed in 160 patients.

    Get PDF
    We could determine the S-phase fraction (SPF) by flow cytometric DNA analysis of paraffin archival material in 160 of 260 patients with soft-tissue sarcoma of extremity and trunk wall. The prognostic value of SPF was compared with other clinicopathological factors. The median follow-up time was 16 (6-31) years. In a univariate analysis, deep tumour location, increasing tumour size and histological malignancy grade, microscopic tumour necrosis, vascular invasion, DNA non-diploidy and high SPF (>3.0%) were associated with poor metastasis-free survival. In a multivariate analysis, microscopic tumour necrosis and high SPF were independently prognostic for metastasis. Used in combination with tumour size, microscopic tumour necrosis and vascular invasion, SPF could identify a group of patients with a 5-year metastasis-free survival rate of 0.97. This group constituted one-quarter of all patients. Patients with low SPF who did recur had a prolonged clinical course both as regards metastases and local recurrence. We conclude that SPF is a valuable adjunct in prognostication in soft-tissue sarcoma

    High-fidelity state detection and tomography of a single ion Zeeman qubit

    Full text link
    We demonstrate high-fidelity Zeeman qubit state detection in a single trapped 88 Sr+ ion. Qubit readout is performed by shelving one of the qubit states to a metastable level using a narrow linewidth diode laser at 674 nm followed by state-selective fluorescence detection. The average fidelity reached for the readout of the qubit state is 0.9989(1). We then measure the fidelity of state tomography, averaged over all possible single-qubit states, which is 0.9979(2). We also fully characterize the detection process using quantum process tomography. This readout fidelity is compatible with recent estimates of the detection error-threshold required for fault-tolerant computation, whereas high-fidelity state tomography opens the way for high-precision quantum process tomography
    corecore