66 research outputs found

    Integration and fusion of standard automated perimetry and optical coherence tomography data for improved automated glaucoma diagnostics

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The performance of glaucoma diagnostic systems could be conceivably improved by the integration of functional and structural test measurements that provide relevant and complementary information for reaching a diagnosis. The purpose of this study was to investigate the performance of data fusion methods and techniques for simple combination of Standard Automated Perimetry (SAP) and Optical Coherence Tomography (OCT) data for the diagnosis of glaucoma using Artificial Neural Networks (ANNs).</p> <p>Methods</p> <p>Humphrey 24-2 SITA standard SAP and StratusOCT tests were prospectively collected from a randomly selected population of 125 healthy persons and 135 patients with glaucomatous optic nerve heads and used as input for the ANNs. We tested commercially available standard parameters as well as novel ones (fused OCT and SAP data) that exploit the spatial relationship between visual field areas and sectors of the OCT peripapillary scan circle. We evaluated the performance of these SAP and OCT derived parameters both separately and in combination.</p> <p>Results</p> <p>The diagnostic accuracy from a combination of fused SAP and OCT data (95.39%) was higher than that of the best conventional parameters of either instrument, i.e. SAP Glaucoma Hemifield Test (p < 0.001) and OCT Retinal Nerve Fiber Layer Thickness ≥ 1 quadrant (p = 0.031). Fused OCT and combined fused OCT and SAP data provided similar Area under the Receiver Operating Characteristic Curve (AROC) values of 0.978 that were significantly larger (p = 0.047) compared to ANNs using SAP parameters alone (AROC = 0.945). On the other hand, ANNs based on the OCT parameters (AROC = 0.970) did not perform significantly worse than the ANNs based on the fused or combined forms of input data. The use of fused input increased the number of tests that were correctly classified by both SAP and OCT based ANNs.</p> <p>Conclusions</p> <p>Compared to the use of SAP parameters, input from the combination of fused OCT and SAP parameters, and from fused OCT data, significantly increased the performance of ANNs. Integrating parameters by including a priori relevant information through data fusion may improve ANN classification accuracy compared to currently available methods.</p

    Binocular summation and other forms of non-dominant eye contribution in individuals with strabismic amblyopia during habitual viewing

    Get PDF
    YesAdults with amblyopia ('lazy eye'), long-standing strabismus (ocular misalignment) or both typically do not experience visual symptoms because the signal from weaker eye is given less weight than the signal from its fellow. Here we examine the contribution of the weaker eye of individuals with strabismus and amblyopia with both eyes open and with the deviating eye in its anomalous motor position. The task consisted of a blue-on-yellow detection task along a horizontal line across the central 50 degrees of the visual field. We compare the results obtained in ten individuals with strabismic amblyopia with ten visual normals. At each field location in each participant, we examined how the sensitivity exhibited under binocular conditions compared with sensitivity from four predictions, (i) a model of binocular summation, (ii) the average of the monocular sensitivities, (iii) dominant-eye sensitivity or (iv) non-dominant-eye sensitivity. The proportion of field locations for which the binocular summation model provided the best description of binocular sensitivity was similar in normals (50.6%) and amblyopes (48.2%). Average monocular sensitivity matched binocular sensitivity in 14.1% of amblyopes' field locations compared to 8.8% of normals'. Dominant-eye sensitivity explained sensitivity at 27.1% of field locations in amblyopes but 21.2% in normals. Non-dominant-eye sensitivity explained sensitivity at 10.6% of field locations in amblyopes but 19.4% in normals. Binocular summation provided the best description of the sensitivity profile in 6/10 amblyopes compared to 7/10 of normals. In three amblyopes, dominant-eye sensitivity most closely reflected binocular sensitivity (compared to two normals) and in the remaining amblyope, binocular sensitivity approximated to an average of the monocular sensitivities. Our results suggest a strong positive contribution in habitual viewing from the non-dominant eye in strabismic amblyopes. This is consistent with evidence from other sources that binocular mechanisms are frequently intact in strabismic and amblyopic individuals

    Retinal nerve fiber layer thickness and cognitive ability in older people:the Lothian Birth Cohort 1936 study

    Get PDF
    BACKGROUND: This study aims to examine the relationship between the retinal nerve fiber layer (RNFL) thickness as measured by optical coherence tomography (OCT) and lifetime cognitive change in healthy older people. METHODS: In a narrow-age sample population from the Lothian Birth Cohort 1936 who were all aged approximately 72 years when tested, participants underwent RNFL measurements using OCT. General linear modeling was used to calculate the effect of RNFL thickness on three domains; general cognitive ability (g-factor), general processing speed (g-speed) and general memory ability (g-memory) using age at time of assessment and gender as co-variates. RESULTS: Of 105 participants, 96 completed OCT scans that were of suitable quality for assessment were analyzed. Using age and gender as covariates, we found only one significant association, between the inferior area RNFL thickness and g-speed (p = 0.049, η(2) = 0.045). Interestingly, when we included age 11 IQ as a covariate in addition to age and gender, there were several statistically significant associations (p = 0.029 to 0.048, η(2) = 0.00 to 0.059) in a negative direction; decreasing scores on measures of g-factor and g-speed were associated with increasing RNFL thickness (r = −0.229 to −0.243, p < 0.05). No significant associations were found between RNFL thickness and g-memory ability. When we considered the number of years of education as a covariate, we found no significant associations between the RNFL thickness and cognitive scores. CONCLUSIONS: In a community dwelling cohort of healthy older people, increased RNFL thickness appeared to be associated with lower general processing speed and lower general cognitive ability when age 11 IQ scores were included as a covariate

    Glaucoma surgery with or without adjunctive antiproliferatives in normal tension glaucoma: 1 Intraocular pressure control and complications

    No full text
    BACKGROUND—Reduction of intraocular pressure (IOP) by 20-30% with glaucoma drainage surgery slows disease progression in normal tension glaucoma (NTG). It is not clear whether adjunctive antiproliferative agents are necessary or safe in eyes at low risk for scarring.
METHOD—86 eyes of 73 white NTG patients who had undergone a primary guarded fistulising procedure were reviewed. 25 eyes had no antiproliferatives, 36 had peroperative 5-fluorouracil (5-FU) and 25 had peroperative mitomycin C (MMC). Their postoperative IOPs, complications, and changes in visual acuity were recorded.
RESULTS—Eyes that had no adjunctive antiproliferative less commonly maintained a 20-30% reduction in IOP (47.4% at 2 years) compared with either the 5-FU group (69.4%at 2 years, p=0.01) or the MMC group (64.9% at 2 years, p=0.04). Eyes that had adjunctive MMC more often had late hypotony (28%, p=0.02) and late bleb leak (12%, p<0.001). Eyes that had adjunctive MMC also more often had a two lines loss of Snellen visual acuity (39.8% by 2 years) compared with those that had adjunctive 5-FU (14.7% by 2 years), p=0.06.
CONCLUSION—For NTG patients at low risk of scarring trabeculectomy with adjunctive peroperative 5-FU should maintain a suitable target IOP without the additional sight threatening complications seen with adjunctive MMC.

    • …
    corecore