11 research outputs found
Pre-hospital videoconferencing telemedicine: are we there yet?
AimsÂ
Pre-Hospital telemedicine has the potential to save lives. This study examined the challenges in the development of a mobile audio-visual telemedicine platform for the pre-hospital telemedicine component of the European Commission funded LiveCity project.Â
MethodsÂ
Open source software and off-the-shelf hardware elements were used to build a wearable field unit for the paramedic to communicate from the scene of an emergency via live video with the Emergency Department hub over a Third Generation (3G)/High Speed Packet Access (HSPA) network.Â
ResultsÂ
Videoconferencing from the scene was compromised in all but one of thirty-four telemedical consultations. Significant challenges in software and hardware suitability, durability, and reliability were identified. The 3G network was unable to provide for an uninterrupted high-quality mobile video link between the paramedic and the Emergency Department.Â
DiscussionÂ
Improvements in hardware and software design with bespoke telemedicine equipment appropriate to the pre-hospital environment as well as investment in fourth (4G) and fifth generation (5G) networks with more extensive coverage will be required to further enable the widespread adoption of optimal telemedicine in pre-hospital care.</p
Recommended from our members
Patient preferences for key drivers and facilitators of adoption of mHealth technology to manage depression: A discrete choice experiment
BackgroundIn time, we may be able to detect the early onset of symptoms of depression and even predict relapse using behavioural data gathered through mobile technologies. However, barriers to adoption exist and understanding the importance of these factors to users is vital to ensure maximum adoption.MethodIn a discrete choice experiment, people with a history of depression (N = 171) were asked to select their preferred technology from a series of vignettes containing four characteristics: privacy, clinical support, established benefit and device accuracy (i.e., ability to detect symptoms), with different levels. Mixed logit models were used to establish what was most likely to affect adoption. Sub-group analyses explored effects of age, gender, education, technology acceptance and familiarity, and nationality.ResultsHigher level of privacy, greater clinical support, increased perceived benefit and better device accuracy were important. Accuracy was the most important, with only modest compromises willing to be made to increase other factors such as privacy. Established benefit was the least valued of the attributes with participants happy with technology that had possible but unknown benefits. Preferences were moderated by technology acceptance, age, nationality, and educational background.ConclusionFor people with a history of depression, adoption of technology may be driven by the desire for accurate detection of symptoms. However, people with lower technology acceptance and educational attainment, those who were younger, and specific nationalities may be willing to compromise on some accuracy for more privacy and clinical support. These preferences should help shape design of mHealth tools.</p
Swift and XMM-Newton observations of the extraordinary gamma-ray burst 060729: More than 125 days of x-ray afterglow
We report the results of the Swift andXMM-Newton observations of the Swift -discovered GRB 060729 (T90 = 115 s).
The afterglow of this burst was exceptionally bright in X-rays as well as at UV/optical wavelengths, showing an
unusually long slow decay phase ( Alpha = 0.14 +/- 0.02), suggesting a larger energy injection phase at early times than
in other bursts. The X-ray light curve displays a break at about 60 ks after the burst. The X-ray decay slope after the
break is Alpha = 1.29 +/- 0.03. Up to 125 days after the burst we do not detect a jet break, suggesting that the jet opening
angle is larger than 28 degrees. We find that the X-ray spectra of the early phase change dramatically and can all be fitted by
an absorbed singleYpower-law models or alternatively by a blackbody plus power-law model. The power-law fits
show that the X-ray spectrum becomes steeper while the absorption column density decreases. In the blackbody
model the temperature decreases from kT = 0.6 to 0.1 keV between 85 and 160 s after the burst in the rest frame. The
afterglow was clearly detected up to 9 days after the burst in all six UVOT filters and in UVW1 even for 31 days. A
break at about 50 ks is clearly detected in all six UVOT filters from a shallow decay slope of about 0.3 and a steeper
decay slope of 1.3.The XMM-Newton observations started about 12 hr after the burst and show a typical afterglow
X-ray spectrum with Beta[SUBSCRIPT x] = 1.1 and absorption column density of 1 x 10^21 cm^-
Continuous glucose monitoring in pregnant women with type 1 diabetes (CONCEPTT): a multicentre international randomised controlled trial
Background
Pregnant women with type 1 diabetes are a high-risk population who are recommended to strive for optimal glucose control, but neonatal outcomes attributed to maternal hyperglycaemia remain suboptimal. Our aim was to examine the effectiveness of continuous glucose monitoring (CGM) on maternal glucose control and obstetric and neonatal health outcomes.
Methods
In this multicentre, open-label, randomised controlled trial, we recruited women aged 18â40 years with type 1 diabetes for a minimum of 12 months who were receiving intensive insulin therapy. Participants were pregnant (â€13 weeks and 6 days' gestation) or planning pregnancy from 31 hospitals in Canada, England, Scotland, Spain, Italy, Ireland, and the USA. We ran two trials in parallel for pregnant participants and for participants planning pregnancy. In both trials, participants were randomly assigned to either CGM in addition to capillary glucose monitoring or capillary glucose monitoring alone. Randomisation was stratified by insulin delivery (pump or injections) and baseline glycated haemoglobin (HbA1c). The primary outcome was change in HbA1c from randomisation to 34 weeks' gestation in pregnant women and to 24 weeks or conception in women planning pregnancy, and was assessed in all randomised participants with baseline assessments. Secondary outcomes included obstetric and neonatal health outcomes, assessed with all available data without imputation. This trial is registered with ClinicalTrials.gov, number NCT01788527.
Findings
Between March 25, 2013, and March 22, 2016, we randomly assigned 325 women (215 pregnant, 110 planning pregnancy) to capillary glucose monitoring with CGM (108 pregnant and 53 planning pregnancy) or without (107 pregnant and 57 planning pregnancy). We found a small difference in HbA1c in pregnant women using CGM (mean difference â0·19%; 95% CI â0·34 to â0·03; p=0·0207). Pregnant CGM users spent more time in target (68% vs 61%; p=0·0034) and less time hyperglycaemic (27% vs 32%; p=0·0279) than did pregnant control participants, with comparable severe hypoglycaemia episodes (18 CGM and 21 control) and time spent hypoglycaemic (3% vs 4%; p=0·10). Neonatal health outcomes were significantly improved, with lower incidence of large for gestational age (odds ratio 0·51, 95% CI 0·28 to 0·90; p=0·0210), fewer neonatal intensive care admissions lasting more than 24 h (0·48; 0·26 to 0·86; p=0·0157), fewer incidences of neonatal hypoglycaemia (0·45; 0·22 to 0·89; p=0·0250), and 1-day shorter length of hospital stay (p=0·0091). We found no apparent benefit of CGM in women planning pregnancy. Adverse events occurred in 51 (48%) of CGM participants and 43 (40%) of control participants in the pregnancy trial, and in 12 (27%) of CGM participants and 21 (37%) of control participants in the planning pregnancy trial. Serious adverse events occurred in 13 (6%) participants in the pregnancy trial (eight [7%] CGM, five [5%] control) and in three (3%) participants in the planning pregnancy trial (two [4%] CGM and one [2%] control). The most common adverse events were skin reactions occurring in 49 (48%) of 103 CGM participants and eight (8%) of 104 control participants during pregnancy and in 23 (44%) of 52 CGM participants and five (9%) of 57 control participants in the planning pregnancy trial. The most common serious adverse events were gastrointestinal (nausea and vomiting in four participants during pregnancy and three participants planning pregnancy).
Interpretation
Use of CGM during pregnancy in patients with type 1 diabetes is associated with improved neonatal outcomes, which are likely to be attributed to reduced exposure to maternal hyperglycaemia. CGM should be offered to all pregnant women with type 1 diabetes using intensive insulin therapy. This study is the first to indicate potential for improvements in non-glycaemic health outcomes from CGM use
Recommended from our members
Event-by-event direction reconstruction of solar neutrinos in a high light-yield liquid scintillator
The direction of individual B8 solar neutrinos has been reconstructed using the SNO+ liquid scintillator detector. Prompt, directional Cherenkov light was separated from the slower, isotropic scintillation light using time information, and a maximum likelihood method was used to reconstruct the direction of individual scattered electrons. A clear directional signal was observed, correlated with the solar angle. The observation was aided by a period of low primary fluor concentration that resulted in a slower scintillator decay time. This is the first time that event-by-event direction reconstruction in high light-yield liquid scintillator has been demonstrated in a large-scale detector.</p
<i>Gaia</i> Focused Product Release: Asteroid orbital solution
Context. We report the exploitation of a sample of Solar System observations based on data from the third Gaia Data Release (Gaia DR3) of nearly 157 000 asteroids. It extends the epoch astrometric solution over the time coverage planned for the Gaia DR4, which is not expected before the end of 2025. This data set covers more than one full orbital period for the vast majority of these asteroids. The orbital solutions are derived from the Gaia data alone over a relatively short arc compared to the observation history of many of these asteroids.
Aims. The work aims to produce orbital elements for a large set of asteroids based on 66 months of accurate astrometry provided by Gaia and to assess the accuracy of these orbital solutions with a comparison to the best available orbits derived from independent observations. A second validation is performed with accurate occultation timings.
Methods. We processed the raw astrometric measurements of Gaia to obtain astrometric positions of moving objects with 1D sub-mas accuracy at the bright end. For each asteroid that we matched to the data, an orbit fitting was attempted in the form of the best fit of the initial conditions at the median epoch. The force model included Newtonian and relativistic accelerations to derive the observation equations, which were solved with a linear least-squares fit.
Results. Orbits are provided in the form of state vectors in the International Celestial Reference Frame for 156 764 asteroids, including near-Earth objects, main-belt asteroids, and Trojans. For the asteroids with the best observations, the (formal) relative uncertainty Ïa/a is better than 10â10. Results are compared to orbits available from the Jet Propulsion Laboratory and MPC. Their orbits are based on much longer data arcs, but from positions of lower quality. The relative differences in semi-major axes have a mean of 5 Ă 10â10 and a scatter of 5 Ă 10â9
<i>Gaia</i> Focused Product Release: Radial velocity time series of long-period variables
Context. The third Gaia Data Release (DR3) provided photometric time series of more than 2 million long-period variable (LPV) candidates. Anticipating the publication of full radial-velocity data planned with Data Release 4, this Focused Product Release (FPR) provides radial-velocity time series for a selection of LPV candidates with high-quality observations.
Aims. We describe the production and content of the Gaia catalog of LPV radial-velocity time series, and the methods used to compute the variability parameters published as part of the Gaia FPR.
Methods. Starting from the DR3 catalog of LPV candidates, we applied several filters to construct a sample of sources with high-quality radial-velocity measurements. We modeled their radial-velocity and photometric time series to derive their periods and amplitudes, and further refined the sample by requiring compatibility between the radial-velocity period and at least one of the G, GBP, or GRP photometric periods.
Results. The catalog includes radial-velocity time series and variability parameters for 9614 sources in the magnitude range 6 âČ G/mag âČ 14, including a flagged top-quality subsample of 6093 stars whose radial-velocity periods are fully compatible with the values derived from the G, GBP, and GRP photometric time series. The radial-velocity time series contain a mean of 24 measurements per source taken unevenly over a duration of about three years. We identify the great majority of the sources (88%) as genuine LPV candidates, with about half of them showing a pulsation period and the other half displaying a long secondary period. The remaining 12% of the catalog consists of candidate ellipsoidal binaries. Quality checks against radial velocities available in the literature show excellent agreement. We provide some illustrative examples and cautionary remarks.
Conclusions. The publication of radial-velocity time series for almost ten thousand LPV candidates constitutes, by far, the largest such database available to date in the literature. The availability of simultaneous photometric measurements gives a unique added value to the Gaia catalog
<i>Gaia</i> Focused Product Release: Sources from Service Interface Function image analysis
Context. Gaiaâs readout window strategy is challenged by very dense fields in the sky. Therefore, in addition to standard Gaia observations, full Sky Mapper (SM) images were recorded for nine selected regions in the sky. A new software pipeline exploits these Service Interface Function (SIF) images of crowded fields (CFs), making use of the availability of the full two-dimensional (2D) information. This new pipeline produced half a million additional Gaia sources in the region of the omega Centauri (Ï Cen) cluster, which are published with this Focused Product Release. We discuss the dedicated SIF CF data reduction pipeline, validate its data products, and introduce their Gaia archive table.
Aims. Our aim is to improve the completeness of the Gaia source inventory in a very dense region in the sky, Ï Cen.
Methods. An adapted version of Gaiaâs Source Detection and Image Parameter Determination software located sources in the 2D SIF CF images. These source detections were clustered and assigned to new SIF CF or existing Gaia sources by Gaia s cross-match software. For the new sources, astrometry was calculated using the Astrometric Global Iterative Solution software, and photometry was obtained in the Gaia DR3 reference system. We validated the results by comparing them to the public Gaia DR3 catalogue and external Hubble Space Telescope data.
Results. With this Focused Product Release, 526 587 new sources have been added to the Gaia catalogue in Ï Cen. Apart from positions and brightnesses, the additional catalogue contains parallaxes and proper motions, but no meaningful colour information. While SIF CF source parameters generally have a lower precision than nominal Gaia sources, in the cluster centre they increase the depth of the combined catalogue by three magnitudes and improve the source density by a factor of ten.
Conclusions. This first SIF CF data publication already adds great value to the Gaia catalogue. It demonstrates what to expect for the fourth Gaia catalogue, which will contain additional sources for all nine SIF CF regions
Gaia Data Release 2: The kinematics of globular clusters and dwarf galaxies around the Milky Way
Aims. The goal of this paper is to demonstrate the outstanding quality of the second data release of the Gaia mission and its power for constraining many different aspects of the dynamics of the satellites of the Milky Way. We focus here on determining the proper motions of 75 Galactic globular clusters, nine dwarf spheroidal galaxies, one ultra-faint system, and the Large and Small Magellanic Clouds.Methods. Using data extracted from the Gaia archive, we derived the proper motions and parallaxes for these systems, as well as their uncertainties. We demonstrate that the errors, statistical and systematic, are relatively well understood. We integrated the orbits of these objects in three different Galactic potentials, and characterised their properties. We present the derived proper motions, space velocities, and characteristic orbital parameters in various tables to facilitate their use by the astronomical community.Results. Our limited and straightforward analyses have allowed us for example to (i) determine absolute and very precise proper motions for globular clusters; (ii) detect clear rotation signatures in the proper motions of at least five globular clusters; (iii) show that the satellites of the Milky Way are all on high-inclination orbits, but that they do not share a single plane of motion; (iv) derive a lower limit for the mass of the Milky Way of 9.1-2.6+6.2 Ă 1011 Mâ based on the assumption that the Leo I dwarf spheroidal is bound; (v) derive a rotation curve for the Large Magellanic Cloud based solely on proper motions that is competitive with line-of-sight velocity curves, now using many orders of magnitude more sources; and (vi) unveil the dynamical effect of the bar on the motions of stars in the Large Magellanic Cloud.Conclusions. All these results highlight the incredible power of the Gaia astrometric mission, and in particular of its second data release.</div
<i>Gaia</i> Data Release 3
Gaia Data Release 3 provides novel flux-calibrated low-resolution spectrophotometry for â220 million sources in the wavelength range 330 nm †λ †1050 nm (XP spectra). Synthetic photometry directly tied to a flux in physical units can be obtained from these spectra for any passband fully enclosed in this wavelength range. We describe how synthetic photometry can be obtained from XP spectra, illustrating the performance that can be achieved under a range of different conditions â for example passband width and wavelength range â as well as the limits and the problems affecting it. Existing top-quality photometry can be reproduced within a few per cent over a wide range of magnitudes and colour, for wide and medium bands, and with up to millimag accuracy when synthetic photometry is standardised with respect to these external sources. Some examples of potential scientific application are presented, including the detection of multiple populations in globular clusters, the estimation of metallicity extended to the very metal-poor regime, and the classification of white dwarfs. A catalogue providing standardised photometry for â2.2â
Ăâ
108 sources in several wide bands of widely used photometric systems is provided (Gaia Synthetic Photometry Catalogue; GSPC) as well as a catalogue of â105 white dwarfs with DA/non-DA classification obtained with a Random Forest algorithm (Gaia Synthetic Photometry Catalogue for White Dwarfs; GSPC-WD)