9,670 research outputs found
Nematicity as a route to a magnetic field-induced spin density wave order; application to the high temperature cuprates
The electronic nematic order characterized by broken rotational symmetry has
been suggested to play an important role in the phase diagram of the high
temperature cuprates. We study the interplay between the electronic nematic
order and a spin density wave order in the presence of a magnetic field. We
show that a cooperation of the nematicity and the magnetic field induces a
finite coupling between the spin density wave and spin-triplet staggered flux
orders. As a consequence of such a coupling, the magnon gap decreases as the
magnetic field increases, and it eventually condenses beyond a critical
magnetic field leading to a field-induced spin density wave order. Both
commensurate and incommensurate orders are studied, and the experimental
implications of our findings are discussed.Comment: 5 pages, 3 figure
Suppression of X-rays from radiative shocks by their thin-shell instability
We examine X-rays from radiatively cooled shocks, focusing on how their
thin-shell instability reduces X-ray emission. For 2D simulations of collision
between equal expanding winds, we carry out a parameter study of such
instability as a function of the ratio of radiative vs. adiabatic-expansion
cooling lengths. In the adiabatic regime, the extended cooling layer suppresses
instability, leading to planar shock compression with X-ray luminosity that
follows closely the expected (Lx ~ M^2) quadratic scaling with mass-loss rate M
. In the strongly radiative limit, the X-ray emission now follows an expected
linear scaling with mass loss (Lx ~ M), but the instability deforms the shock
compression into extended shear layers with oblique shocks along fingers of
cooled, dense material. The spatial dispersion of shock thermalization limits
strong X-ray emission to the tips and troughs of the fingers, and so reduces
the X-ray emission (here by about a factor 1/50) below what is expected from
analytic radiative-shock models without unstable structure. Between these two
limits, X-ray emission can switch between a high-state associated with extended
shock compression, and a low-state characterized by extensive shear. Further
study is needed to clarify the origin of this "shear mixing reduction factor"
in X-ray emission, and its dependence on parameters like the shock Mach number
Recommended from our members
Sequential Changes of Plasma C-Reactive Protein, Erythrocyte Sedimentation Rate and White Blood Cell Count in Spine Surgery : Comparison between Lumbar Open Discectomy and Posterior Lumbar Interbody Fusion.
ObjectiveC-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) are often utilized to evaluate for postoperative infection. Abnormal values may be detected after surgery even in case of non-infection because of muscle injury, transfusion, which disturbed prompt perioperative management. The purpose of this study was to evaluate and compare the perioperative CRP, ESR, and white blood cell (WBC) counts after spine surgery, which was proved to be non-infection.MethodsTwenty patients of lumbar open discectomy (LOD) and 20 patients of posterior lumbar interbody fusion (PLIF) were enrolled in this study. Preoperative and postoperative prophylactic antibiotics were administered routinely for 7 days. Blood samples were obtained one day before surgery and postoperative day (POD) 1, POD3, and POD7. Using repeated measures ANOVA, changes in effect measures over time and between groups over time were assessed. All data analysis was conducted using SAS v.9.1.ResultsChanges in CRP, within treatment groups over time and between treatment groups over time were both statistically significant F(3,120)=5.05, p=0.003 and F(1,39)=7.46, p=0.01, respectively. Most dramatic changes were decreases in the LOD group on POD3 and POD7. Changes in ESR, within treatment groups over time and between treatment groups over time were also found to be statistically significant, F(3,120)=6.67, p=0.0003 and F(1,39)=3.99, p=0.01, respectively. Changes in WBC values also were be statistically significant within groups over time, F(3,120)=40.52, p<0.001, however, no significant difference was found in between groups WBC levels over time, F(1,39)=0.02, p=0.89.ConclusionWe found that, dramatic decrease of CRP was detected on POD3 and POD7 in LOD group of non-infection and dramatic increase of ESR on POD3 and POD7 in PLIF group of non-infection. We also assumed that CRP would be more effective and sensitive parameter especially in LOD than PLIF for early detection of infectious complications. Awareness of the typical pattern of CRP, ESR, and WBC may help to evaluate the early postoperative course
A novel method of increasing the range of 1.65µm OTDR using a Q-switched erbium fibre laser
This paper demonstrates a novel method of increasing the range of a 1.65µm optical time domain reflectometer system (OTDR). OTDR measurements at 1.65µm are more sensitive to fibre macro and micro bending losses than those produced at wavelengths 1.3 and 1.55µm. This enables problems to be identified in their early stages reducing the risk of total system failure. However, the dynamic range of current 1.65µm OTDR systems
Fully integrated CMOS power amplifier design using the distributed active-transformer architecture
A novel on-chip impedance matching and power-combining method, the distributed active transformer is presented. It combines several low-voltage push-pull amplifiers efficiently with their outputs in series to produce a larger output power while maintaining a 50-Ω match. It also uses virtual ac grounds and magnetic couplings extensively to eliminate the need for any off-chip component, such as tuned bonding wires or external inductors. Furthermore, it desensitizes the operation of the amplifier to the inductance of bonding wires making the design more reproducible. To demonstrate the feasibility of this concept, a 2.4-GHz 2-W 2-V truly fully integrated power amplifier with 50-Ω input and output matching has been fabricated using 0.35-μm CMOS transistors. It achieves a power added efficiency (PAE) of 41 % at this power level. It can also produce 450 mW using a 1-V supply. Harmonic suppression is 64 dBc or better. This new topology makes possible a truly fully integrated watt-level gigahertz range low-voltage CMOS power amplifier for the first time
A 2.4-GHz, 2.2-W, 2-V fully-integrated CMOS circular-geometry active-transformer power amplifier
A 2.4-GHz, 2.2-W, 2-V fully integrated circular geometry power amplifier with 50 Ω input and output matching is fabricated using 2.5V, 0.35 pm CMOS transistors. It can also produce 450mW using a 1V supply. Harmonic suppression is 64dB or better. An on-chip circular-geometry active-transformer is used to combine several push-pull low-voltage amplifiers efficiently to produce a larger output power while maintaining a 50 Ω match. This new on-chip power combining and impedance matching method uses virtual ac grounds and magnetic couplings extensively to eliminate the need for any off-chip component such as wirebonds. It also desensitizes the operation of the amplifier to the inductance of bonding wires and makes the design more reproducible. This new topology makes possible a fully-integrated 2.2W, 2.4GHz, low voltage CMOS power amplifier for the first time
Stereotactic guidance for navigated percutaneous sacroiliac joint fusion.
Arthrodesis of the sacroiliac joint (SIJ) for surgical treatment of SIJ dysfunction has regained interest among spine specialists. Current techniques described in the literature most often utilize intraoperative fluoroscopy to aid in implant placement; however, image guidance for SIJ fusion may allow for minimally invasive percutaneous instrumentation with more precise implant placement. In the following cases, we performed percutaneous stereotactic navigated sacroiliac instrumentation using O-arm® multidimensional surgical imaging with StealthStation® navigation (Medtronic, Inc. Minneapolis, MN). Patients were positioned prone and an image-guidance reference frame was placed contralateral to the surgical site. O-arm® integrated with StealthStation® allowed immediate auto-registration. The skin incision was planned with an image-guidance probe. An image-guided awl, drill and tap were utilized to choose a starting point and trajectory. Threaded titanium cage(s) packed with autograft and/or allograft were then placed. O-arm® image-guidance allowed for implant placement in the SIJ with a small skin incision. However, we could not track the cage depth position with our current system, and in one patient, the SIJ cage had to be revised secondary to the anterior breach of sacrum
- …
