37 research outputs found
Profile Monitor SEM's for the NuMI Beam at FNAL
The Neutrinos at the Main Injector (NuMI) project will extract 120 GeV
protons from the FNAL Main Injector in 8.56usec spills of 4E13 protons every
1.9 sec. We have designed secondary emission monitor (SEM) detectors to measure
beam profile and halo along the proton beam transport line. The SEM?s are Ti
foils 5um in thickness segmented in either 1?mm or 0.5?mm pitch strips,
resulting in beam loss ~5E-6. We discuss aspects of the mechanical design,
calculations of expected beam heating, and results of a beam test at the 8 GeV
transport line to MiniBoone at FNAL.Comment: to appear in proceedings of 11th Beam Instrumentation Workshop, Oak
Ridge, T
Beam-Based Alignment of the NuMI Target Station Components at FNAL
The Neutrinos at the Main Injector (NuMI) facility is a conventional
horn-focused neutrino beam which produces muon neutrinos from a beam of mesons
directed into a long evacuated decay volume. The relative alignment of the
primary proton beam, target, and focusing horns affects the neutrino energy
spectrum delivered to experiments. This paper describes a check of the
alignment of these components using the proton beam.Comment: higher resolution figures available on Fermilab Preprint Server (see
SPIRES entry), accepted for publication in Nucl. Instr. and Meth.
Beam Test of a Segmented Foil SEM Grid
A prototype Secondary-electron Emission Monitor (SEM) was installed in the 8
GeV proton transport line for the MiniBooNE experiment at Fermilab. The SEM is
a segmented grid made with 5 um Ti foils, intended for use in the 120 GeV NuMI
beam at Fermilab. Similar to previous workers, we found that the full
collection of the secondary electron signal requires a bias voltage to draw the
ejected electrons cleanly off the foils, and this effect is more pronounced at
larger beam intensity. The beam centroid and width resolutions of the SEM were
measured at beam widths of 3, 7, and 8 mm, and compared to calculations.
Extrapolating the data from this beam test, we expect a centroid and width
resolutions of 20um and 25 um, respectively, in the NuMI beam which has 1 mm
spot size.Comment: submitted to Nucl. Instr. Meth.
Study of Neutron-Induced Ionization in Helium and Argon Chamber Gases
Ion chambers used to monitor the secondary hadron and tertiary muon beam in
the NuMI neutrino beamline will be exposed to background particles, including
low energy neutrons produced in the beam dump. To understand these backgrounds,
we have studied Helium- and Argon-filled ionization chambers exposed to intense
neutron fluxes from PuBe neutron sources ( MeV). The sources emit
about 10 neutrons per second. The number of ion pairs in the chamber gas
volume per incident neutron is derived. While limited in precision because of a
large gamma ray background from the PuBe sources, our results are consistent
with the expectation that the neutrons interact purely elastically in the
chamber gas.Comment: accepted for publication in NIM
Secondary Beam Monitors for the NuMI Facility at FNAL
The Neutrinos at the Main Injector (NuMI) facility is a conventional neutrino
beam which produces muon neutrinos by focusing a beam of mesons into a long
evacuated decay volume. We have built four arrays of ionization chambers to
monitor the position and intensity of the hadron and muon beams associated with
neutrino production at locations downstream of the decay volume. This article
describes the chambers' construction, calibration, and commissioning in the
beam.Comment: Accepted for publication in Nucl. Instr. Meth.
Ion Chambers for Monitoring the NuMI Neutrino Beam at FNAL
The Neutrinos at the Main Injector (NuMI) beamline will deliver an intense
muon neutrino beam by focusing a beam of mesons into a long evacuated decay
volume. The beam must be steered with 1 mRad angular accuracy toward the Soudan
Underground Laboratory in northern Minnesota. We have built 4 arrays of
ionization chambers to monitor the neutrino beam direction and quality. The
arrays are located at 4 stations downstream of the decay volume, and measure
the remnant hadron beam and tertiary muons produced along with neutrinos in
meson decays. We review how the monitors will be used to make beam quality
measurements, and as well we review chamber construction details, radiation
damage testing, calibration, and test beam results.Comment: paper to appear in the proceedings of the 11th Beam Instrumentation
Workshop, Oak Ridge, T
Recommended from our members
Segmented foil SEM grids at Fermilab
We present recent beam data from a new design of a profile monitor for proton beams at Fermilab. The monitors, consisting of grids of segmented Ti foils 5{micro}m thick, are secondary-electron emission monitors (SEM's) We review data on the device's precision on beam centroid position, beam width, and on beam loss associated with the SEM material placed in the beam
