Performance of Sequoyah Containment Anchorage System
Deformation of a steel containment anchorage system during a severe accident may result in a leakage path at the containment boundaries. Current design criteria are based on either ductile or brittle failure modes of headed bolts that do not account for factors such as cracking of the containment basemat or deformation of the anchor bolt that may affect the behavior of the containment anchorage system. The purpose of this study was to investigate the performance of a typical ice condenser containment`s anchorage system. This was accomplished by analyzing the Sequoyah Containment Anchorage System. Based on a strength of materials approach and assuming that the anchor bolts are resisting the uplift caused by the internal pressure, one can estimate that the failure of the anchor bolts would occur at a containment pressure of 79 psig. To verify these results and to calibrate the strength of materials equation, the Sequoyah containment anchorage system was analyzed with the ABAQUS program using a three-dimensional, finite-element model. The model included portions of the steel containment building, shield building, anchor bolt assembly, reinforced concrete mat and soil foundation material
Evaluation of Steel Bridges, Volumes I & II
This report is divided into two volumes. Volume I summarizes a structural health monitoring (SHM) system that was developed for the Iowa DOT to remotely and continuously monitor fatigue critical bridges (FCB) to aid in the detection of crack formation. The developed FCB SHM system enables bridge owners to remotely monitor FCB for gradual or sudden damage formation. The SHM system utilizes fiber bragg grating (FBG) fiber optic sensors (FOSs) to measure strains at critical locations. The strain-based SHM system is trained with measured performance data to identify typical bridge response when subjected to ambient traffic loads, and that knowledge is used to evaluate newly collected data. At specified intervals, the SHM system autonomously generates evaluation reports that summarize the current behavior of the bridge. The evaluation reports are collected and distributed to the bridge owner for interpretation and decision making. This volume (Volume II) summarizes the development and demonstration of an autonomous, continuous SHM system that can be used to monitor typical girder bridges. The developed SHM system can be grouped into two main categories: an office component and a field component. The office component is a structural analysis software program that can be used to generate thresholds which are used for identifying isolated events. The field component includes hardware and field monitoring software which performs data processing and evaluation. The hardware system consists of sensors, data acquisition equipment, and a communication system backbone. The field monitoring software has been developed such that, once started, it will operate autonomously with minimal user interaction. In general, the SHM system features two key uses. First, the system can be integrated into an active bridge management system that tracks usage and structural changes. Second, the system helps owners to identify damage and deterioration
Recommended from our members
Three-dimensional analysis of AP600 standard plant shield building roof
The AP600 passive containment vessel is surrounded by a concrete cylindrical shell covered with a truncated conical roof. This roof supports the passive containment cooling system (PCS) annular tank, shield plate and other nonstructural attachments. When the shield building is subjected to different loading combinations as defined in the Standard Review Plan (SRP), some of the sections in the shield building could experience forces in excess of their design values. This report summarized the three-dimensional finite element analysis that was conducted to review the adequacy of the proposed Westinghouse shield building design. The ANSYS finite element software was utilized to analyze the Shield Building Roof (SBR) under dead, snow, wind, thermal and seismic loadings. A three-dimensional model that included a portion of the shield building cylindrical shell, the conical roof and its attachments, the eccentricities at the cone-cylinder connection and at the compression ring and the PCS tank was developed. Mesh sensitivity studies were conducted to select appropriate element size in the cylinder, cone, near air intakes and in the vicinity of the eccentricities. Also, a study was carried out to correctly idealize the water-structure interaction in the PCS tank. Response spectrum analysis was used to calculate the internal forces at different sections in the SBR under Safe Shutdown Earthquake (SSE). Forty-nine structural modes and twenty sloshing modes were used. Two horizontal components of the SSE together with a vertical component were used. Modal stress resultants were combined taking into account the effects of closely spaced modes. The three earthquake directions were combined by the Square Root of the Sum Squares method. Two load combinations were studied. The load combination that included dead, snow, fluid, thermal and seismic loads was selected to be the most critical. Interaction diagrams for critical sections were developed and used to check the design adequacy. The results demonstrated that provided area of steal on each face of several sections of the AP600 SBR was inadequate. This was also noticed when comparing the total provided area of steel per section, i.e., the area of steel on both faces. The discrepancy between Westinghouse results and these reported herein could have resulted from the different finite element mesh sizes and the assumption used in Westinghouse design
Photoreactivation and dark repair of ultraviolet light-induced pyrimidine dimers in chloroplast DNA.
A UV-specific endonuclease was used to detect ultraviolet light-induced pyrimidine dimers in chloroplast DNA of Chlamydomonas reinhardi that was specifically labeled with tritiated thymidine. All of the dimers induced by 100 J/m2 of 254 nm light are removed by photoreaction. Wild-type cells exposed to 50 J/m2 of UF light removed over 80% of the dimers from chloroplast DNA after 24 h of incubation in growth medium in the dark. A UV- sensitive mutant, UVS1, defective in the excision of pyrimidine dimers from nuclear DNA is capable of removing pyrimidine dimers from chloroplast DNA nearly as well as wild-type, suggesting that nuclear and chloroplast DNA dark-repair systems are under separate genetic control