407 research outputs found

    Main aspects of forensic medicineʼs expertise in case of providing an illegal abortion manipulation in Poland: history, abortion is an acute problem of the modern polish society, a key role of forensic medicals in legal regulation of this guestions

    Get PDF
    Abortion questions are not new in the sphere of medical discussions in Poland. Especially, this topic became more acute in 2016, when it was no citizen, who could not be interested in this problem. Let us speak and describe the main aspects of taking up position of abortion manipulations in Poland. In 1993 Polish Parliament accepted the law in sphere of ‘Family planning, protecting of the fetus and conditions of pregnancy interruption’. according to this law, providing abortion service was permitted only in few cases, that was strictly described by legislation. And that main cases were: 1) pregnancy in undoubtedly threat for a woman’s health; 2) fetus has strong diseases or mature defect; 3) pregnancy was a result of crime

    Antiviral cellular therapy for enhancing T-cell reconstitution before or after hematopoietic stem cell transplantation (ACES): A two-arm, open label phase II interventional trial of pediatric patients with risk factor assessment

    Get PDF
    Viral infections remain a major risk in immunocompromised pediatric patients, and virus-specific T cell (VST) therapy has been successful for treatment of refractory viral infections in prior studies. We performed a phase II multicenter study (NCT03475212) for the treatment of pediatric patients with inborn errors of immunity and/or post allogeneic hematopoietic stem cell transplant with refractory viral infections using partially-HLA matched VSTs targeting cytomegalovirus, Epstein-Barr virus, or adenovirus. Primary endpoints were feasibility, safety, and clinical responses (\u3e1 log reduction in viremia at 28 days). Secondary endpoints were reconstitution of antiviral immunity and persistence of the infused VSTs. Suitable VST products were identified for 75 of 77 clinical queries. Clinical responses were achieved in 29 of 47 (62%) of patients post-HSCT including 73% of patients evaluable at 1-month post-infusion, meeting the primary efficacy endpoint (\u3e52%). Secondary graft rejection occurred in one child following VST infusion as described in a companion article. Corticosteroids, graft-versus-host disease, transplant-associated thrombotic microangiopathy, and eculizumab treatment correlated with poor response, while uptrending absolute lymphocyte and CD8 T cell counts correlated with good response. This study highlights key clinical factors that impact response to VSTs and demonstrates the feasibility and efficacy of this therapy in pediatric HSCT

    High-fidelity correction of genomic uracil by human mismatch repair activities

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Deamination of cytosine to produce uracil is a common and potentially mutagenic lesion in genomic DNA. U•G mismatches occur spontaneously throughout the genome, where they are repaired by factors associated with the base excision repair pathway. U•G mismatches are also the initiating lesion in immunoglobulin gene diversification, where they undergo mutagenic processing by redundant pathways, one dependent upon uracil excision and the other upon mismatch recognition by MutSα. While UNG is well known to initiate repair of uracil in DNA, the ability of MutSα to direct correction of this base has not been directly demonstrated.</p> <p>Results</p> <p>Using a biochemical assay for mismatch repair, we show that MutSα can promote efficient and faithful repair of U•G mismatches, but does not repair U•A pairs in DNA. This contrasts with UNG, which readily excises U opposite either A or G. Repair of U•G by MutSα depends upon DNA polymerase δ (pol δ), ATP, and proliferating cell nuclear antigen (PCNA), all properties of canonical mismatch repair.</p> <p>Conclusion</p> <p>These results show that faithful repair of U•G can be carried out by either the mismatch repair or base excision repair pathways. Thus, the redundant functions of these pathways in immunoglobulin gene diversification reflect their redundant functions in faithful repair. Faithful repair by either pathway is comparably efficient, suggesting that mismatch repair and base excision repair share the task of faithful repair of genomic uracil.</p

    Beam profile investigation of the new collimator system for the J-PET detector

    Get PDF
    Jagiellonian Positron Emission Tomograph (J-PET) is a multi-purpose detector which will be used for search for discrete symmetries violations in the decays of positronium atoms and for investigations with positronium atoms in life-sciences and medical diagnostics. In this article we present three methods for determination of the beam profile of collimated annihilation gamma quanta. Precise monitoring of this profile is essential for time and energy calibration of the J-PET detector and for the determination of the library of model signals used in the hit-time and hit-position reconstruction. We have we have shown that usage of two lead bricks with dimensions of 5x10x20 cm^3 enables to form a beam of annihilation quanta with Gaussian profile characterized by 1 mm FWHM. Determination of this characteristic is essential for designing and construction the collimator system for the 24-module J-PET prototype. Simulations of the beam profile for different collimator dimensions were performed. This allowed us to choose optimal collimation system in terms of the beam profile parameters, dimensions and weight of the collimator taking into account the design of the 24 module J-PET detector.Comment: 14 pages, 9 figure

    Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system

    Get PDF
    The Jagiellonian Positron Emission Tomograph (J-PET) was constructed as a prototype of the cost-effective scanner for the simultaneous metabolic imaging of the whole human body. Being optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolution, it constitutes a multi-purpose detector providing new opportunities for studying the decays of positronium atoms. Positronium is the lightest purely leptonic object decaying into photons. As an atom bound by a central potential it is a parity eigenstate, and as an atom built out of an electron and an anti-electron it is an eigenstate of the charge conjugation operator. Therefore, the positronium is a unique laboratory to study discrete symmetries whose precision is limited in principle by the effects due to the weak interactions expected at the level of (~1014^{-14}) and photon-photon interactions expected at the level of (~109^{-9}). The J-PET detector enables to perform tests of discrete symmetries in the leptonic sector via the determination of the expectation values of the discrete-symmetries-odd operators, which may be constructed from the spin of ortho-positronium atom and the momenta and polarization vectors of photons originating from its annihilation. In this article we present the potential of the J-PET detector to test the C, CP, T and CPT symmetries in the decays of positronium atoms.Comment: 27 pages, 6 figure

    Processing optimization with parallel computing for the J-PET tomography scanner

    Get PDF
    The Jagiellonian-PET (J-PET) collaboration is developing a prototype TOF-PET detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast, FPGA-based front-end electronics and the data acquisition system, as well as, low- and high-level reconstruction algorithms were specially developed to be used with the J-PET scanner. The TOF-PET data processing and reconstruction are time and resource demanding operations, especially in case of a large acceptance detector, which works in triggerless data acquisition mode. In this article, we discuss the parallel computing methods applied to optimize the data processing for the J-PET detector. We begin with general concepts of parallel computing and then we discuss several applications of those techniques in the J-PET data processing.Comment: 8 page

    A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

    Get PDF
    We present a study of the application of the Jagiellonian Positron Emission Tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetric and high acceptance scanner can be used as a multi-purpose detector well suited to pursue research including e.g. tests of discrete symmetries in decays of ortho-positronium in addition to the medical imaging. The gamma quanta originating from o-Ps decay interact in the plastic scintillators predominantly via the Compton effect, making the direct measurement of their energy impossible. Nevertheless, it is shown in this paper that the J-PET scanner will enable studies of the o-Ps3γ\to3\gamma decays with angular and energy resolution equal to σ(θ)0.4\sigma(\theta) \approx 0.4^{\circ} and σ(E)4.1\sigma(E) \approx 4.1 keV, respectively. An order of magnitude shorter decay time of signals from plastic scintillators with respect to the inorganic crystals results not only in better timing properties crucial for the reduction of physical and instrumental background, but also suppresses significantly the pileups, thus enabling compensation of the lower efficiency of the plastic scintillators by performing measurements with higher positron source activities

    Analysis framework for the J-PET scanner

    Get PDF
    J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. In this article we present the implementation of the full data-processing chain in the J-PET framework which is used for the data analysis of the J-PET tomography scanner. The Framework incorporates automated handling of PET setup parameters' database as well as high level tools for building data reconstruction procedures. Each of these components is briefly discussed.Comment: 6 pages, 1 figur

    Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector

    Get PDF
    In this paper we present prospects for using the J-PET detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays into three photons. No zero expectation values for chosen correlations between ortho-positronium spin and momentum vectors of photons would imply the existence of physics phenomena beyond the Standard Model. Previous measurements resulted in violation amplitude parameters for CP and CPT symmetries consistent with zero, with an uncertainty of about 10-3. The J-PET detector allows to determine those values with better precision thanks to a unique time and angular esolution combined with a high geometrical acceptance. Achieving the aforementioned is possible due to application of polymer scintillators instead of crystals as detectors of annihilation quanta.Comment: in Nukleonika 201

    Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector

    Full text link
    This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and allows for a simultaneous reconstruction of both location and time of the decay. Results of resolution tests of the new reconstruction in the J-PET detector based on Monte Carlo simulations are presented, which yield a spatial resolution at the level of 2 cm (FWHM) for X and Y and at the level of 1 cm (FWHM) for Z available with the present resolution of J-PET after application of a kinematic fit. Prospects of employment of this method for studying angular correlations of photons in decays of polarized ortho-positronia for the needs of tests of CP and CPT discrete symmetries are also discussed. The new reconstruction method allows for discrimination of background from random three-photon coincidences as well as for application of a novel method for determination of the linear polarization of ortho-positronium atoms, which is also introduced in this work.Comment: 18 pages, 5 figures. Accepted for publication in Nuclear Instrumentation and Methods in Physics Research
    corecore