21 research outputs found

    Synthesis of the Ti-Silicate Form of BEC Polymorph of B-Zeolite Assisted by Molecular Modeling

    Full text link
    This document is the Accepted Manuscript version of a Published Work that appeared in final form in The Journal of Physical Chemistry C, copyright © American Chemical Society after peer review and technical editing by the publisher. To access the final edited and published work see http://doi.org/10.1021/jp805400u Published Work, see http://pubs.acs.org/page/policy/articlesonrequest/index.html[EN] The K(+) free pure silica form of polymorph C (BEC) of beta-zeolite has been synthesized with a cationic organic structure directing agent (SDA) that was predicted best, out of a series of nine potentials, by means of modeling techniques. On the bases of this synthesis method, the Ti-BEC zeolite has been obtained which owing to the pore topology and dimensions shows a higher epoxidation activity than the Ti-beta-polymorph either with H(2)O(2) or organic peroxides as oxidants.The authors thank the CICYT for financial support (Project MAT 2006-14274-CO2-01). G.S. thanks "Centro de Calculo de la Universidad Politecnica de Valencia" for the use of their computational facilities. M.M. and P.S. thank ITQ for a scholarship. We also thank intramural project CRENATUM.Moliner Marin, M.; Serna Merino, PM.; Cantin Sanz, A.; Sastre Navarro, GI.; Díaz Cabañas, MJ.; Corma Canós, A. (2008). Synthesis of the Ti-Silicate Form of BEC Polymorph of B-Zeolite Assisted by Molecular Modeling. The Journal of Physical Chemistry C. 112(49):19547-19554. https://doi.org/10.1021/jp805400uS19547195541124

    Seguimiento de las guías españolas para el manejo del asma por el médico de atención primaria: un estudio observacional ambispectivo

    Get PDF
    Objetivo Evaluar el grado de seguimiento de las recomendaciones de las versiones de la Guía española para el manejo del asma (GEMA 2009 y 2015) y su repercusión en el control de la enfermedad. Material y métodos Estudio observacional y ambispectivo realizado entre septiembre del 2015 y abril del 2016, en el que participaron 314 médicos de atención primaria y 2.864 pacientes. Resultados Utilizando datos retrospectivos, 81 de los 314 médicos (25, 8% [IC del 95%, 21, 3 a 30, 9]) comunicaron seguir las recomendaciones de la GEMA 2009. Al inicio del estudio, 88 de los 314 médicos (28, 0% [IC del 95%, 23, 4 a 33, 2]) seguían las recomendaciones de la GEMA 2015. El tener un asma mal controlada (OR 0, 19, IC del 95%, 0, 13 a 0, 28) y presentar un asma persistente grave al inicio del estudio (OR 0, 20, IC del 95%, 0, 12 a 0, 34) se asociaron negativamente con tener un asma bien controlada al final del seguimiento. Por el contrario, el seguimiento de las recomendaciones de la GEMA 2015 se asoció de manera positiva con una mayor posibilidad de que el paciente tuviera un asma bien controlada al final del periodo de seguimiento (OR 1, 70, IC del 95%, 1, 40 a 2, 06). Conclusiones El escaso seguimiento de las guías clínicas para el manejo del asma constituye un problema común entre los médicos de atención primaria. Un seguimiento de estas guías se asocia con un control mejor del asma. Existe la necesidad de actuaciones que puedan mejorar el seguimiento por parte de los médicos de atención primaria de las guías para el manejo del asma. Objective: To assess the degree of compliance with the recommendations of the 2009 and 2015 versions of the Spanish guidelines for managing asthma (Guía Española para el Manejo del Asma [GEMA]) and the effect of this compliance on controlling the disease. Material and methods: We conducted an observational ambispective study between September 2015 and April 2016 in which 314 primary care physicians and 2864 patients participated. Results: Using retrospective data, we found that 81 of the 314 physicians (25.8%; 95% CI 21.3–30.9) stated that they complied with the GEMA2009 recommendations. At the start of the study, 88 of the 314 physicians (28.0%; 95% CI 23.4–33.2) complied with the GEMA2015 recommendations. Poorly controlled asthma (OR, 0.19; 95% CI 0.13–0.28) and persistent severe asthma at the start of the study (OR, 0.20; 95% CI 0.12–0.34) were negatively associated with having well-controlled asthma by the end of the follow-up. In contrast, compliance with the GEMA2015 recommendations was positively associated with a greater likelihood that the patient would have well-controlled asthma by the end of the follow-up (OR, 1.70; 95% CI 1.40–2.06). Conclusions: Low compliance with the clinical guidelines for managing asthma is a common problem among primary care physicians. Compliance with these guidelines is associated with better asthma control. Actions need to be taken to improve primary care physician compliance with the asthma management guidelines

    A synthesis, MAS NMR, synchrotron X-ray powder diffraction, and computational study of zeolite SSZ-23

    No full text
    The zeolite SSZ-23 (STT) is the first zeolite found to contain channels bounded by seven and nine tetrahedral atom windows. A survey of the synthetic conditions needed to prepare SSZ-23 has been carried out, and the resulting materials characterized by synchrotron X-ray powder diffraction and magic-angle spinning NMR spectroscopy to obtain details of the long-range crystalline structure and short-range connectivity defects. The lattice energy minimized structure is in excellent agreement with the experimental results, and a comparison with other zeolites that have been simulated in this way is made.</p

    A synthesis, MAS NMR, synchrotron X-ray powder diffraction, and computational study of zeolite SSZ-23

    No full text
    The zeolite SSZ-23 (STT) is the first zeolite found to contain channels bounded by seven and nine tetrahedral atom windows. A survey of the synthetic conditions needed to prepare SSZ-23 has been carried out, and the resulting materials characterized by synchrotron X-ray powder diffraction and magic-angle spinning NMR spectroscopy to obtain details of the long-range crystalline structure and short-range connectivity defects. The lattice energy minimized structure is in excellent agreement with the experimental results, and a comparison with other zeolites that have been simulated in this way is made.</p

    Diseño y comparativa de biomateriales para el tratamiento de defectos óseos. Estudio de su comportamiento in vivo en modelo animal de conejo

    No full text
    Objetivo: Comparar in vivo la capacidad de formación ósea de dos tipos de biomateriales diseñados como sustitutivos óseos respecto a autoinjerto de cresta iliaca, uno basado en carbonatohidroxiapatita y otro en vidrio mesoporoso bioactivo. Material y método: Estudio experimental compuesto por 14 conejos de Nueva Zelanda hembras adultas donde se realizó un defecto crítico en hueso radio. La muestra fue dividida en cuatro grupos: defecto sin material, con autoinjerto de cresta iliaca, con soporte de carbonatohidroxiapatita y con soporte de vidrio mesoporoso bioactivo. Se realizaron estudios seriados de radiología simple a las 2, 4, 6 y 12 semanas y estudio de micro-TC a eutanasia a las 6 y 12 semanas. Resultados: En el estudio de radiología simple, el grupo de autoinjerto mostró las mayores puntuaciones de formación ósea (7,5 puntos). Ambos grupos de biomateriales presentaron formación ósea similar (5,3 y 6 puntos, respectivamente) y mayor al defecto sin material (4 puntos), pero siempre menor que el grupo de autoinjerto. Los resultados del estudio de micro-TC mostraron el mayor volumen de hueso en el área de estudio en el grupo de autoinjerto. Los grupos con sustitutivos óseos presentaron mayor volumen de hueso que el grupo sin material, pero siempre menor que en el grupo de autoinjerto.Fundación de la Sociedad Espanola de Cirugía Ortopédica y TraumatologíaInstituto de salud Carlos IIIDepto. de Química en Ciencias FarmacéuticasFac. de FarmaciaTRUEpu
    corecore