11 research outputs found

    Le service de santé de Montréal de l'établissement au démantèlement (1865-1975)

    Get PDF
    Au cours de la décennie 1970, le Québec entreprend une vaste réforme de son système de santé qui aboutit au démantèlement des anciennes structures de santé publique mises en place à partir de 1926 comme les unités sanitaires de comté ou de la fin du xixe siècle comme le service de santé de la ville de Montréal. Cette étude, en cours et partie d'une enquête plus vaste sur les conditions d'institutionnalisation des pratiques de santé publique au Québec du milieu du xixe s. à nos jours, analyse ..

    Impact of stagnation and sampling volume on water microbial quality monitoring in large buildings

    Get PDF
    Microbial drinking water quality can be altered in large buildings, especially after stagnation. In this study, bacterial profiles were generated according to the stagnation time and the volume of water collected at the tap. Successive volumes of cold and hot water were sampled after controlled stagnation periods. Bacterial profiles revealed an important decline (> 2 log) in culturable cells in the first 500 mL sampled from the hot and cold water systems, with a steep decline in the first 15 mL. The strong exponential correlation (R2 >/= 0.97) between the culturable cell counts in water and the pipe surface-to-volume ratio suggests the biofilm as the main contributor to the rapid increase in suspended culturable cells measured after a short stagnation of one-hour. Results evidence the contribution of the high surface-to-volume ratio at the point of use and the impact of short stagnation times on the increased bacterial load observed. Simple faucets with minimal internal surface area should be preferred to minimize surface area. Sampling protocol, including sampling volume and prior stagnation, was also shown to impact the resulting culturable cell concentration by more than 1000-fold. Sampling a smaller volume on first draw after stagnation will help maximize recovery of bacteria

    Hospital drains as reservoirs of Pseudomonas aeruginosa: Multiple-locus variable-number of tandem repeats analysis genotypes recovered from faucets, sink surfaces and patients

    Get PDF
    Identifying environmental sources of Pseudomonas aeruginosa (Pa) related to hospital-acquired infections represents a key challenge for public health. Biofilms in water systems offer protection and favorable growth conditions, and are prime reservoirs of microorganisms. A comparative genotyping survey assessing the relationship between Pa strains recovered in hospital sink biofilm and isolated in clinical specimens was conducted. Environmental strains from drain, faucet and sink-surface biofilm were recovered by a culture method after an incubation time ranging from 48 to 240 h. The genotyping of 38 environmental and 32 clinical isolates was performed using a multiple-locus variable-number of tandem repeats analysis (MLVA). More than one-third of Pa isolates were only cultivable following >/=48 h of incubation, and were predominantly from faucet and sink-surface biofilms. In total, 41/70 strains were grouped within eight genotypes (A to H). Genotype B grouped a clinical and an environmental strain isolated in the same ward, 5 months apart, suggesting this genotype could thrive in both contexts. Genotype E grouped environmental isolates that were highly prevalent throughout the hospital and that required a longer incubation time. The results from the multi-hospital follow-up study support the drain as an important reservoir of Pa dissemination to faucets, sink surfaces and patients. Optimizing the recovery of environmental strains will strengthen epidemiological investigations, facilitate pathway identification, and assist in identifying and controlling the reservoirs potentially associated to hospital-acquired infections

    Impact of stagnation and sampling volume on water microbial quality monitoring in large buildings

    No full text
    <div><p>Microbial drinking water quality can be altered in large buildings, especially after stagnation. In this study, bacterial profiles were generated according to the stagnation time and the volume of water collected at the tap. Successive volumes of cold and hot water were sampled after controlled stagnation periods. Bacterial profiles revealed an important decline (> 2 log) in culturable cells in the first 500 mL sampled from the hot and cold water systems, with a steep decline in the first 15 mL. The strong exponential correlation (R<sup>2</sup> ≥ 0.97) between the culturable cell counts in water and the pipe surface-to-volume ratio suggests the biofilm as the main contributor to the rapid increase in suspended culturable cells measured after a short stagnation of one-hour. Results evidence the contribution of the high surface-to-volume ratio at the point of use and the impact of short stagnation times on the increased bacterial load observed. Simple faucets with minimal internal surface area should be preferred to minimize surface area. Sampling protocol, including sampling volume and prior stagnation, was also shown to impact the resulting culturable cell concentration by more than 1000-fold. Sampling a smaller volume on first draw after stagnation will help maximize recovery of bacteria.</p></div

    Sampling sequence illustrating the origin of the water within the premise plumbing, and estimated surface-to-volume ratio for each section.

    No full text
    <p>Sampling sequence illustrating the origin of the water within the premise plumbing, and estimated surface-to-volume ratio for each section.</p

    Apparent cell release per unit of pipe surface in cold water during stagnation at the tap.

    No full text
    <p>Release of bacteria was calculated based on cell increase over the duration of the stagnation period, for (a) culturable, (b) viable and (c) total cells.</p

    Mean HPC concentration calculated for the cumulated sampling volume after 1 h stagnation (n = 2) and 24h or more of stagnation (n = 10).

    No full text
    <p>HPC concentrations is shown as a function of sampling volume for the first liter collected at the tap and after 5 minutes of flush time.</p

    Hospital Drains as Reservoirs of Pseudomonas aeruginosa: Multiple-Locus Variable-Number of Tandem Repeats Analysis Genotypes Recovered from Faucets, Sink Surfaces and Patients

    No full text
    Identifying environmental sources of Pseudomonas aeruginosa (Pa) related to hospital-acquired infections represents a key challenge for public health. Biofilms in water systems offer protection and favorable growth conditions, and are prime reservoirs of microorganisms. A comparative genotyping survey assessing the relationship between Pa strains recovered in hospital sink biofilm and isolated in clinical specimens was conducted. Environmental strains from drain, faucet and sink-surface biofilm were recovered by a culture method after an incubation time ranging from 48 to 240 h. The genotyping of 38 environmental and 32 clinical isolates was performed using a multiple-locus variable-number of tandem repeats analysis (MLVA). More than one-third of Pa isolates were only cultivable following ≥48 h of incubation, and were predominantly from faucet and sink-surface biofilms. In total, 41/70 strains were grouped within eight genotypes (A to H). Genotype B grouped a clinical and an environmental strain isolated in the same ward, 5 months apart, suggesting this genotype could thrive in both contexts. Genotype E grouped environmental isolates that were highly prevalent throughout the hospital and that required a longer incubation time. The results from the multi-hospital follow-up study support the drain as an important reservoir of Pa dissemination to faucets, sink surfaces and patients. Optimizing the recovery of environmental strains will strengthen epidemiological investigations, facilitate pathway identification, and assist in identifying and controlling the reservoirs potentially associated to hospital-acquired infections
    corecore