20 research outputs found

    Investigation of the use of Coincidences Between Fast Neutrons and Gamma Rays for the Detection of Special Nuclear Materials

    Get PDF
    The emergence of new methodologies with promising applications that could impact nuclear security and emergency preparedness detection systems in the near future motivate the development of computational tools that allow the theoretical investigation of the relevant design parameters for such detection systems. Here, we present Monte Carlo simulations using the MCNP6 code to investigate the use of fast neutron-neutron and gamma-neutron coincidences in addition to conventional methods for detection of special nuclear materials (SNM) using inorganic scintillator detectors. The results show fair agreement between MCNP6 and MCNP-PoliMi simulations for neutron-neutron coincidences and that coincident detection of gamma rays and fast neutrons has a potential for enhancing the sensitivity for detection of SNM compared with conventional gamma-ray, single-neutron, and fast neutron-neutron coincidence detection schemes

    La renovación de la palabra en el bicentenario de la Argentina : los colores de la mirada lingüística

    Get PDF
    El libro reúne trabajos en los que se exponen resultados de investigaciones presentadas por investigadores de Argentina, Chile, Brasil, España, Italia y Alemania en el XII Congreso de la Sociedad Argentina de Lingüística (SAL), Bicentenario: la renovación de la palabra, realizado en Mendoza, Argentina, entre el 6 y el 9 de abril de 2010. Las temáticas abordadas en los 167 capítulos muestran las grandes líneas de investigación que se desarrollan fundamentalmente en nuestro país, pero también en los otros países mencionados arriba, y señalan además las áreas que recién se inician, con poca tradición en nuestro país y que deberían fomentarse. Los trabajos aquí publicados se enmarcan dentro de las siguientes disciplinas y/o campos de investigación: Fonología, Sintaxis, Semántica y Pragmática, Lingüística Cognitiva, Análisis del Discurso, Psicolingüística, Adquisición de la Lengua, Sociolingüística y Dialectología, Didáctica de la lengua, Lingüística Aplicada, Lingüística Computacional, Historia de la Lengua y la Lingüística, Lenguas Aborígenes, Filosofía del Lenguaje, Lexicología y Terminología

    Influence of the presence of tissue expanders on energy deposition for post-mastectomy radiotherapy.

    Get PDF
    An increasing number of studies have shown that post-mastectomy radiotherapy presents benefits associated with the patients survival and a significant fraction of the treated patients makes use of tissue expanders for breast reconstruction. Some models of tissue expanders have a magnetic disk on their surface that constitutes heterogeneity in the radiation field, which can affect the dose distribution during the radiotherapy treatment. In this study, the influence of a metallic heterogeneity positioned in a breast tissue expander was evaluated by means of Monte Carlo simulations using the MCNPX code and using Eclipse treatment planning system. Deposited energy values were calculated in structures which have clinical importance for the treatment. Additionally, the effect in the absorbed energy due to backscattering and attenuation of the incident beam caused by the heterogeneity, as well as due to the expansion of the prosthesis, was evaluated in target structures for a 6 MV photon beam by simulations. The dose distributions for a breast treatment were calculated using a convolution/superposition algorithm from the Eclipse treatment planning system. When compared with the smallest breast expander volume, underdosage of 7% was found for the largest volume of breast implant, in the case of frontal irradiation of the chest wall, by Monte Carlo simulations. No significant changes were found in dose distributions for the presence of the heterogeneity during the treatment planning of irradiation with an opposed pair of beams. Even considering the limitation of the treatment planning system, the results obtained with its use confirm those ones found by Monte Carlo simulations for a tangent beam irradiation. The presence of a heterogeneity didn't alters the dose distributions on treatment structures. The underdosage of 7% observed with Monte Carlo simulations were found for irradiation at 0°, not used frequently in a clinical routine

    Evaluation of the radiotherapy treatment planning in the presence of a magnetic valve tissue expander.

    No full text
    The combination of radiotherapy treatments and breast reconstruction, using temporary tissue expanders, generates several concerns due to the presence of a magnetic valve inside the radiation field. The objective of this work is to evaluate a radiotherapy treatment planning for a patient using a tissue expander. Isodose curve maps, obtained using radiochromic films, were compared to the ones calculated with two different dose calculation algorithms of the Eclipse radiotherapy Treatment Planning System (TPS), considering the presence or absence of the heterogeneity. The TPS calculation considering the presence of the heterogeneity shows changes around 5% in the isodose curves when they were compared with the calculation without heterogeneity correction. This calculation did not take in account the real density value of the heterogeneity. This limitation was quantified to be around 10% in comparison with the TPS calculation and experimental measurements using the radiochromic film. These results show that the magnetic valve should be taken in account in dose calculations of the TPS. With respect to the AAA and Pencil Beam Convolution algorithms, when the calculation is compared with the real distribution, AAA presents a distribution more similar to experimental dose distribution

    Deposited energy curves calculated with MCNP for the three heterogeneity types studied on the structures representing chest wall and breast tissue and skin (A) 0°, (B) 90° and (C) for 270° irradiation, respectively.

    No full text
    <p>Deposited energy curves calculated with MCNP for the three heterogeneity types studied on the structures representing chest wall and breast tissue and skin (A) 0°, (B) 90° and (C) for 270° irradiation, respectively.</p

    Treatment Planning isodose Curves for the two extremes volumes considered with and without heterogeneity correction algorithm applied.

    No full text
    <p>The curve of 5000cGy is the prescribed curve. (A) Planning Isodose curves for the first volume without heterogeneity correction and (B) with correction; (C) Planning Isodose curves for the last volume without heterogeneity correction and (D) with correction.</p
    corecore