19 research outputs found

    Effectiveness of neonatal pulse oximetry screening for detection of critical congenital heart disease in daily clinical routine—results from a prospective multicenter study

    Get PDF
    Pulse oximetry screening (POS) has been proposed as an effective, noninvasive, inexpensive tool allowing earlier diagnosis of critical congenital heart disease (cCHD). Our aim was to test the hypothesis that POS can reduce the diagnostic gap in cCHD in daily clinical routine in the setting of tertiary, secondary and primary care centres. We conducted a prospective multicenter trial in Saxony, Germany. POS was performed in healthy term and post-term newborns at the age of 24–72 h. If an oxygen saturation (SpO2) of ≤95% was measured on lower extremities and confirmed after 1 h, complete clinical examination and echocardiography were performed. POS was defined as false-negative when a diagnosis of cCHD was made after POS in the participating hospitals/at our centre. From July 2006–June 2008, 42,240 newborns from 34 institutions have been included. Seventy-two children were excluded due to prenatal diagnosis (n = 54) or clinical signs of cCHD (n = 18) before POS. Seven hundred ninety-five newborns did not receive POS, mainly due to early discharge after birth (n = 727; 91%). In 41,445 newborns, POS was performed. POS was true positive in 14, false positive in 40, true negative in 41,384 and false negative in four children (three had been excluded for violation of study protocol). Sensitivity, specificity, positive and negative predictive value were 77.78%, 99.90%, 25.93% and 99.99%, respectively. With POS as an adjunct to prenatal diagnosis, physical examination and clinical observation, the percentage of newborns with late diagnosis of cCHD was 4.4%. POS can substantially reduce the postnatal diagnostic gap in cCHD, and false-positive results leading to unnecessary examinations of healthy newborns are rare. POS should be implemented in routine postnatal care

    Methodology of calculation of construction and hydrodynamic parameters of a foam layer apparatus for mass-transfer processes

    Get PDF
    Промислова реалізація методу стабілізації газорідинного шару дозволяє значно розширити галузь застосування пінних апаратів і відкриває нові можливості інтенсифікації технологічних процесів з одночасним створенням маловідходних технологій. У статті встановлені основні параметри, що впливають на гідродинаміку пінних апаратів, розглянуті основні конструкції та режими роботи пінних апаратів. Виявлено зв'язок гідродинамічних параметрів. Розглянуто гідродинамічні закономірності пінного шару. Вказані фактори, що впливають на процес масообміну, як в газовій, так і в рідкій фазах. Проведений аналіз ряду досліджень показав, що перспективним напрямком інтенсифікації процесу масообміну є розробка апаратів з трифазним псевдозрідженим шаром зрошуваної насадки складних форм із сітчастих матеріалів. Отже, необхідне проведення спеціальних досліджень гідродинамічних режимів роботи апарату з сітчастою насадкою і визначенням параметрів, що впливають на швидкість переходу насадки з одного режиму в інший.Industrial implementation of the stabilization method of the gas-liquid layer can significantly expand the field of use of foaming apparatus and opens up new opportunities for intensifying technological processes with the simultaneous creation of low-waste technologies. The article establishes the basic parameters influencing the hydrodynamics of foam apparatus, considers the basic constructions and operating modes of foam apparatus. The connection of hydrodynamic parameters is revealed. The hydrodynamic laws of the foam layer are considered. The indicated factors affecting the process of mass transfer, both in the gas and in the liquid phases. The conducted analysis of a number of studies showed that the perspective direction of intensification of the mass transfer process is the development of apparatuses with a three-phase fluidized bed of an irrigated nozzle of complex forms with mesh materials

    Cardiac troponin I release after transcatheter atrial septal defect closure depends on occluder size but not on patient’s age

    No full text
    Objective: To examine whether transcatheter closure of secundum atrial septal defect (ASD) with the Amplatzer septal occluder leads to more myocardial injury in children than in adults. Design: In a prospective study with children and adults cardiac troponin I (cTnI) serum concentrations were determined by immunoassay (AxSYM, Abbott Laboratories) before, during, and up to 20 months after surgical or transcatheter ASD closure. Patients: Four groups of patients were studied: transcatheter ASD closure (group 1: 22 children, age range 3.26–14.7 years; group 2: 22 adults, 18.0–67.3 years), surgical ASD closure (group 3: 18 children, 3.12–13.5 years), and diagnostic catheterisation (group 4: 12 children, 2.68–15.0 years). Results: cTnI concentrations were significantly increased after occluder implantation with higher serum concentrations in children than in adults (immediately after implantation: group 1, 3.2 (4.4) μg/l; group 2, 1.1 (4.2) μg/l; four hours after implantation: group 1, 4.8 (5.0) μg/l; group 2, 1.7 (2.3) μg/l; both p < 0.01, group 1 v group 2; one day after implantation: group 1, 3.0 (5.7) μg/l; group 2, 2.2 (5.2) μg/l) but were less than 20% of those after surgical ASD closure (group 3; p < 0.001) where the highest cTnI concentration was found (37.1 (26.3) μg/l). Diagnostic catheterisation (group 4) was not associated with detectable cTnI increase. From the cTnI concentrations the total amount of cTnI released after ASD closure was estimated for each patient. This was dependent on the size of the occluder (p < 0.05) but not on the patient’s age or procedural duration. Conclusion: In regard to interventional ASD closure our data do not provide evidence that the child’s myocardium is more vulnerable. Transcatheter ASD closure induces minor myocardial lesion, the extent of which depends on the size of the Amplatzer septal occluder but is irrespective of the patient’s age

    Balloon valvuloplasty in the treatment of congenital aortic valve stenosis - a retrospective multicenter survey of more than 1000 patients

    Full text link
    In this retrospective multicenter study, balloon valvuloplasty of the aortic valve has effectively postponed the need for surgery in infants, children and adolescents up to 18 years of age
    corecore