91 research outputs found

    Quality assurance in stereotactic radiosurgery/radiotherapy according to DIN 6875-1

    Get PDF
    The new DIN (' Deutsche Industrie- Norm') 6875- 1, which is currently being finalised, deals with quality assurance ( QA) criteria and tests methods for linear accelerator and Gamma Knife stereotactic radiosurgery/ radiotherapy including treatment planning, stereotactic frame and stereotactic imaging and a system test to check the whole chain of uncertainties. Our existing QA program, based on dedicated phantoms and test procedures, has been refined to fulfill the demands of this new DIN. The radiological and mechanical isocentre corresponded within 0.2 mm and the measured 50% isodose lines were in agreement with the calculated ones within less than 0.5 mm. The measured absorbed dose was within 3%. The resultant output factors measured for the 14-, 8- and 4- mm collimator helmet were 0.9870 +/- 0.0086, 0.9578 +/- 0.0057 and 0.8741 +/- 0.0202, respectively. For 170 consecutive tests, the mean geometrical accuracy was 0.48 +/- 0.23 mm. Besides QA phantoms and analysis software developed in- house, the use of commercially available tools facilitated the QA according to the DIN 6875- 1 with which our results complied. Copyright (C) 2004 S. Karger AG, Basel

    Welche Macht darf es denn Sein? Tracing ‘Power’ in German Foreign Policy Discourse

    Get PDF
    The relationship between ‘Germany’ and ‘power’ remains a sensitive issue. While observers tend to agree that Germany has regained the status of the most powerful country in Europe, there is debate whether that is to be welcomed or whether that is a problem. Underpinning this debate are views, both within Germany and amongst its neighbours, regarding the kind of power Germany has, or should (not) have. Against this backdrop, the article reviews the dominant role conceptions used in the expert discourse on German foreign policy since the Cold War that depict Germany as a particular type of ‘power’. Specifically, we sketch the evolution of three prominent conceptions (constrained power, civilian power, hegemonic power) and the recent emergence of a new one (shaping power). The article discusses how these labels have emerged to give meaning to Germany’s position in international relations, points to their normative and political function, and to the limited ability of such role images to tell us much about how Germany actually exercises power

    From Democratic Peace to Democratic Distinctiveness: A Critique of Democratic Exceptionalism in Peace and Conflict Studies

    Full text link

    AI for Doctors-A Course to Educate Medical Professionals in Artificial Intelligence for Medical Imaging

    No full text
    Successful adoption of artificial intelligence (AI) in medical imaging requires medical professionals to understand underlying principles and techniques. However, educational offerings tailored to the need of medical professionals are scarce. To fill this gap, we created the course AI for Doctors: Medical Imaging . An analysis of participants' opinions on AI and self-perceived skills rated on a five-point Likert scale was conducted before and after the course. The participants' attitude towards AI in medical imaging was very optimistic before and after the course. However, deeper knowledge of AI and the process for validating and deploying it resulted in significantly less overoptimism with respect to perceivable patient benefits through AI (p = 0.020). Self-assessed skill ratings significantly improved after the course, and the appreciation of the course content was very positive. However, we observed a substantial drop-out rate, mostly attributed to the lack of time of medical professionals. There is a high demand for educational offerings regarding AI in medical imaging among medical professionals, and better education may lead to a more realistic appreciation of clinical adoption. However, time constraints imposed by a busy clinical schedule need to be taken into account for successful education of medical professionals
    corecore