1,336 research outputs found

    Proposta de organização e visualização de grande quantidade de imagens orbitais através de web services.

    Get PDF
    The organization of satellite imagery seeks to facilitate the presentation and manipulation of spatial information in projects of Land Management's Strategic area from Embrapa Satellite Monitoring, enabling integration between mapped data and interoperability of image data and mapped regions. As a way to standardize this organization, we followed the recommendations of national and international bodies that deal with the standardization of geographic metadata, specifically satellite images. To view this integration, a webmapping interface was created. A webmapping must be prepared to meet the needs of relationship between user and product. In this paper we propose a standardized structure for storage and maintenance of images obtained by satellite sensors aiming its availability on the web through web map services, examples of interoperability. The non-interoperability prevents sharing of information and computing resources. The visualization of web map services takes place through a webmapping that benefits from the organization structure of satellite images proposed in this paper. The hierarchical organization proposed research assistance of satellite images. As they are entered into the database, now new images will be organized in a logical structure, without affecting the search for listings older images. The webmapping allows a direct link between the metadata and geospatial data visualization. Combining web services based on Geographic Information Systems (GIS) in conjunction with the Flex technology allows the creation of Rich Internet Applications (RIA) giving the user more possibilities of interaction via the Web

    Preservação e organização da geoinformação em instituições: o caso da construção da Infraestrutura de Dados Espaciais da Embrapa.

    Get PDF
    O objetivo deste trabalho é apresentar a estratégia da Embrapa para construir sua Infraestrutura de Dados Espaciais de forma a contribuir com o debate sobre a organização, preservação e integração de dados geoespaciais heterogêneos de acordo com as diretrizes federais estabelecidas pela INDE. Para esse fim, apresentaremos as etapas do processo interno realizado na Embrapa para elaboração o plano de adesão à INDE, o qual contou com a formação de um grupo de trabalho e, em seguida, descreveremos a estratégia elaborada

    Gabapentin Bioequivalence Study: Quantification By Liquid Chromatography Coupled To Mass Spectrometry

    Get PDF
    The study was performed to compare the bioavailability of two gabapentin 400 mg capsule formulation (Gabapentin from Arrow Farmacêutica S/A as test formulation and Neurontin ® from Pfizer, Brazil, as reference formulation) in 26 volunteers of both sexes. The study was conducted open with randomized two period crossover design and a one week wash out period. Plasma samples were obtained over a 48 hour interval. The gabapentin was analyzed by LC/MS/MS, in the presence of pracetamole as internal standard. With plasma concentration vs. time curves, data obtained from this metabolite, the following pharmacokinetics parameters were obtained: AUC 0-t, AUC 0-inf and C max. Geometric mean of gabapentin/Neurontin ® 400 mg individual percent ratio was 100.58% AUC 0-t, 101.35% for AUC 0-inf and 97.76% for C max. The 90% confidence intervals were 92.00 - 109.95%, 93.00 - 110.44%, 88.41 - 108.10%, respectively. Since the 90% confidence intervals for C max, AUC 0-t and AUC 0 -inf were within the 80 - 125% interval proposed by Food and Drug Administration, it was concluded that gabapentin 400 mg capsule was bioequivalent to Neurontin ® 400 mg capsule according to both the rate and extent of absorption. © 2011 Junior EA, et al.38187190Wattananat, T., Akarawut, W., Validated LC-MS-MS Method for the Determination of Gabapentin in Human Plasma: Application to a Bioequivalence Study (2009) J Chromatogr Sci, 47, pp. 868-871Stewart, B.H., Kagler, A.R., Thompson, P.R., Bockbrader, H.N., A saturable transport mechanism in the intestinal absorption of gabapentin is the underlying cause of the lack of proportionality between increasing dose and drug levels in plasma (1993) Pharma Res, 10, pp. 276-281McLean, M.J., Gabapentin in the management of convulsive disorders (1999) Epilepsia, 40, pp. 39-50Goa, K.L., Sorkin, E.M., Gabapentin: A review of its pharmacological properties and clinical potential in epilepsy (1993) Drugs, 46, pp. 409-427Zhu, Z., Neirinck, L., High-performance liquid chromatographic method for the determination of gabapentin in human plasma (2002) J Chromatogr B Analyt Technol Biomed Life Sci, 779, pp. 307-312Sagirli, O., Cetin, S.M., Determination of gabapentin in human plasma and urine by high-performance liquid chromatography with UV-vis detection (2006) J Pharm Biomed Anal, 42, pp. 618-624Jalalizadeh, H., Souri, E., Tehrani, M.B., Jahangiri, A., Validated HPLC method for the determination of gabapentin in human plasma using precolumn derivatization with 1-fluoro-2,4-dinitrobenzene and its application to a pharmacokinetic study (2007) J Chromatogr B Analyt Technol Biomed Life Sci, 854, pp. 43-47Forrest, G., Sills, G.J., Leach, J.P., Brodie, M.J., Determination of gabapentin in plasma by high-performance liquid chromatography (1996) J Chromatogr B Analyt Technol Biomed Life Sci, 681, pp. 421-425Tang, P.H., Miles, M.V., Glauser, T.A., Degrauw, T., Automated microanalysis of gabapentin in human serum by high-performance liquid chromatography with fluorometric detection (1999) J Chromatogr B Analyt Technol Biomed Life Sci, 727, pp. 125-129Hassan, E.M., Belal, F., Al-Deeb, O.A., Khalil, N.Y., Spectrofluorimetric determination of vigabatrin and gabapentin in dosage forms and spiked plasma samples through derivatization with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (2001) J. AOAC Int., 84, pp. 1017-1024Gauthier, D., Gupta, R., Determination of gabapentin in plasma by liquid chromatography with fluorescence detection after solid-phase extraction with a C18 column (2002) Clin Chem, 48, pp. 2259-2261Chung, T.C., Tai, C.T., Wu, H.L., Simple and sensitive liquid chromatographic method with fluorimetric detection for the analysis of gabapentin in human plasma (2006) J Chromatogr A, 119, pp. 294-298Bahrami, G., Kiani, A., Sensitive high-performance liquid chromatographic quantitation of gabapentin in human serum using liquid-liquid extraction and pre-column derivatization with 9-fluorenylmethyl chloroformate (2006) J Chromatogr B Analyt Technol Biomed Life Sci, 835, pp. 123-126Krivanek, P., Koppatz, K., Turnheim, K., Simultaneous isocratic HPLC determination of vigabatrin and gabapentin in human plasma by dansyl derivatization (2003) Ther Drug Monit, 25, pp. 374-377Chang, S.Y., Wang, F.Y., Simple and sensitive liquid chromatographic method with fluorimetric detection for the analysis of gabapentin in human plasma (2004) J Chromatogr B Analyt Technol Biomed Life Sci, 799, pp. 265-270Wolf, C.E., Saady, J.J., Poklis, A., Determination of gabapentin in serum using solid phase extraction and gas-liquid chromatography (1996) J Anal Toxicol, 20, pp. 498-501Kushnir, M.M., Cossett, J., Brown, P.I., Urry, F.M., Analysis of gabapentin in serum and plasma by solid-phase extraction and gas chromatography-mass spectrometry for therapeutic drug monitoring (1999) J Anal Toxicol, 23, pp. 1-6Borrey, D.C., Godderis, K.O., Engelrelst, V.I., Bernard, D.R., Langlois, M.R., Quantitative determination of vigabatrin and gabapentin in human serum by gas chromatography-mass spectrometry (2005) Clin Chim Acta, 354, pp. 147-151Gambelunghe, C., Mariucci, G., Tantucci, M., Ambrosini, M.V., Gas chromatography-tandemmass spectrometry analysis of gabapentin in serum (2005) Biomed Chromatogr, 19, pp. 63-67Matar, K.M., Abdel-Hamid, M.E., Rapid tandem mass spectrometric method for determination of gabapentin in human plasma (2005) Chromatographia, 61, pp. 499-504Ramakrishna, N.V.S., Vishwottam, K.N., Koteshwara, M., Maroj, S., Santosh, M., Rapid quantification of gabapentin in human plasma by liquid chromatography/tandemmass spectrometry (2006) J Pharm Biomed Anal, 40, pp. 360-368Ifa, D.R., Falci, M., Moraes, M.E., Bezerra, F.A., Moraes, M.O., Gabapentin quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study (2001) J Mass Spectrom, 36, pp. 188-194Ji, H.Y., Jeong, D.W., Kim, Y.H., Kim, H.H., Yoon, Y.S., Determination of gabapentin in human plasma using hydrophilic interaction liquid chromatography with tandem mass spectrometry (2006) Rapid Commun Mass Spectrom, 20, pp. 2127-2132Carlsson, K.C., Reubsaet, J.L., Sample preparation and determination of gabapentin in venous and capillary blood using liquid chromatography-tandem mass spectrometry (2004) J Pharm Biomed Anal, 34, pp. 415-423Park, J.H., Jhee, O.H., Park, S.H., Lee, J.S., Lee, M.H., Validated LC-MS/ MS method for quantification of gabapentin in human plasma: Application to pharmacokinetic and bioequivalence studies in Korean volunteers (2007) Biomed Chromatogr, 21, pp. 829-83

    Uso de controlador de versão para desenvolvimento distribuído de software.

    Get PDF
    Este trabalho tem por objetivo apresentar a utilização de um software controlador de versão no desenvolvimento do WebGIS SOMA Brasil da Embrapa Monitoramento por Satélite. O controlador escolhido foi o GIT, por trabalhar de forma distribuída e tornar possível o desenvolvimento de código localmente, ou seja, sem a necessidade de estar conectado a um servidor em tempo integral, comum em outros tipos de controladores de versão. O GIT é uma ferramenta de código aberto criada inicialmente para gerenciamento de atualizações no sistema base do Linux (kernel). Atualmente a ferramenta é utilizada em inúmeros outros projetos, entre eles PostgreSQL, Facebook e Netflix. O trabalho visa apresentar os resultados obtidos na utilização da ferramenta para a integração de código entre diferentes desenvolvedores e para a resolução de problemas decorrentes de modificações feitas em um mesmo arquivo. O GIT também possibilita implementar backup de código com um custo baixo de armazenamento, além de tornar possível fazer um histórico de versões lançadas e/ou em teste. A implantação do sistema GIT permitiu que diferentes desenvolvedores pudessem realizar testes, alterações e melhorias sem afetar diretamente o sistema em produção. Assim que se mostram estáveis e funcionais, as alterações podem ser facilmente incorporadas na versão do sistema em produção

    WebGis Moçambique: organização das bases de dados espaciais para a plataforma GeoServer.

    Get PDF
    bitstream/item/57239/1/024-11.pd

    SOMABRASIL: Sistema de Observação e Monitoramento da Agricultura no Brasil.

    Get PDF
    bitstream/item/69644/1/026-12.pd
    corecore