19 research outputs found

    The Monte Carlo validation framework for the discriminant partial least squares model extended with variable selection methods applied to authenticity studies of Viagra (R) based on chromatographic impurity profiles

    No full text
    &lt;p&gt;The aim of this work was to develop a general framework for the validation of discriminant models based on the Monte Carlo approach that is used in the context of authenticity studies based on chromatographic impurity profiles. The performance of the validation approach was applied to evaluate the usefulness of the diagnostic logic rule obtained from the partial least squares discriminant model (PLS-DA) that was built to discriminate authentic Viagra® samples from counterfeits (a two-class problem). The major advantage of the proposed validation framework stems from the possibility of obtaining distributions for different figures of merit that describe the PLS-DA model such as, e.g., sensitivity, specificity, correct classification rate and area under the curve in a function of model complexity. Therefore, one can quickly evaluate their uncertainty estimates. Moreover, the Monte Carlo model validation allows balanced sets of training samples to be designed, which is required at the stage of the construction of PLS-DA and is recommended in order to obtain fair estimates that are based on an independent set of samples. In this study, as an illustrative example, 46 authentic Viagra® samples and 97 counterfeit samples were analyzed and described by their impurity profiles that were determined using high performance liquid chromatography with photodiode array detection and further discriminated using the PLS-DA approach. In addition, we demonstrated how to extend the Monte Carlo validation framework with four different variable selection schemes: the elimination of uninformative variables, the importance of a variable in projections, selectivity ratio and significance multivariate correlation. The best PLS-DA model was based on a subset of variables that were selected using the variable importance in the projection approach. For an independent test set, average estimates with the corresponding standard deviation (based on 1000 Monte Carlo runs) of the correct classification rate, sensitivity, specificity and area under the curve were equal to 96.42% ± 2.04, 98.69% ± 1.38, 94.16% ± 3.52 and 0.982 ± 0.017, respectively.&lt;/p&gt;</p

    A strategy for the identification of plants in illegal pharmaceutical preparations and food supplements using chromatographic fingerprints

    No full text
    The detection of regulated and forbidden herbs in pharmaceutical preparations and nutritional supplements is a growing problem for laboratories charged with the analysis of illegal pharmaceutical preparations and counterfeit medicines. This article presents a feasibility study of the use of chromatographic fingerprints for the detection of plants in pharmaceutical preparations. Fingerprints were developed for three non-regulated common herbal products-Rhamnus purshiana, Passiflora incarnata L. and Crataegus monogyna-and this was done by combining three different types of detection: diode-array detection, evaporative light scattering detection and mass spectrometry. It is shown that these plants could be detected in respective triturations of the dry extracts with lactose and three different herbal matrices as well as in commercial preparations purchased on the open market</p

    Headspace-gas chromatographic fingerprints to discriminate and classify counterfeit medicines

    No full text
    &lt;p&gt;Counterfeit medicines are a global threat to public health. These pharmaceuticals are not subjected to quality control and therefore their safety, quality and efficacy cannot be guaranteed. Today, the safety evaluation of counterfeit medicines is mainly based on the identification and quantification of the active substances present. However, the analysis of potential toxic secondary components, like residual solvents, becomes more important. Assessment of residual solvent content and chemometric analysis of fingerprints might be useful in the discrimination between genuine and counterfeit pharmaceuticals. Moreover, the fingerprint approach might also contribute in the evaluation of the health risks different types of counterfeit medicines pose. In this study a number of genuine and counterfeit Viagra(®) and Cialis(®) samples were analyzed for residual solvent content using headspace-GC-MS. The obtained chromatograms were used as fingerprints and analyzed using different chemometric techniques: Principal Component Analysis, Projection Pursuit, Classification and Regression Trees and Soft Independent Modelling of Class Analogy. It was tested whether these techniques can distinguish genuine pharmaceuticals from counterfeit ones and if distinct types of counterfeits could be differentiated based on health risks. This chemometric analysis showed that for both data sets PCA clearly discriminated between genuine and counterfeit drugs, and SIMCA generated the best predictive models. This technique not only resulted in a 100% correct classification rate for the discrimination between genuine and counterfeit medicines, the classification of the counterfeit samples was also superior compared to CART. This study shows that chemometric analysis of headspace-GC impurity fingerprints allows to distinguish between genuine and counterfeit medicines and to differentiate between groups of counterfeit products based on the public health risks they pose.&lt;/p&gt;</p

    Detection of sibutramine in adulterated dietary supplements using attenuated total reflectance-infrared spectroscopy

    No full text
    &lt;p&gt;Sibutramine is one of the most occurring adulterants encountered in dietary supplements with slimming as indication. These adulterated dietary supplements often contain a herbal matrix. When customs intercept these kind of supplements it is almost impossible to discriminate between the legal products and the adulterated ones, due to misleading packaging. Therefore in most cases these products are confiscated and send to laboratories for analysis. This results inherently in the confiscation of legal, non-adulterated products. Therefore there is a need for easy to use equipment and techniques to perform an initial screening of samples. Attenuated total reflectance-infrared (ATR-IR) spectroscopy was evaluated for the detection of sibutramine in adulterated dietary supplements. Data interpretation was performed using different basic chemometric techniques. It was found that the use of ATR-IR combined with the k-Nearest Neighbours (k-NN) was able to detect all adulterated dietary supplements in an external test set and this with a minimum of false positive results. This means that a small amount of legal products will still be confiscated and analyzed in a laboratory to be found negative, but no adulterated samples will pass the initial ATR-IR screening.&lt;/p&gt;</p

    Testing of complementarity of PDA and MS detectors using chromatographic fingerprinting of genuine and counterfeit samples containing sildenafil citrate

    No full text
    &lt;p&gt;Counterfeit medicines are a global threat to public health. High amounts enter the European market, which is why characterization of these products is a very important issue. In this study, a high-performance liquid chromatography-photodiode array (HPLC-PDA) and high-performance liquid chromatography-mass spectrometry (HPLC-MS) method were developed for the analysis of genuine Viagra®, generic products of Viagra®, and counterfeit samples in order to obtain different types of fingerprints. These data were included in the chemometric data analysis, aiming to test whether PDA and MS are complementary detection techniques. The MS data comprise both MS1 and MS2 fingerprints; the PDA data consist of fingerprints measured at three different wavelengths, i.e., 254, 270, and 290 nm, and all possible combinations of these wavelengths. First, it was verified if both groups of fingerprints can discriminate between genuine, generic, and counterfeit medicines separately; next, it was studied if the obtained results could be ameliorated by combining both fingerprint types. This data analysis showed that MS1 does not provide suitable classification models since several genuines and generics are classified as counterfeits and vice versa. However, when analyzing the MS1_MS2 data in combination with partial least squares-discriminant analysis (PLS-DA), a perfect discrimination was obtained. When only using data measured at 254 nm, good classification models can be obtained by k nearest neighbors (kNN) and soft independent modelling of class analogy (SIMCA), which might be interesting for the characterization of counterfeit drugs in developing countries. However, in general, the combination of PDA and MS data (254 nm_MS1) is preferred due to less classification errors between the genuines/generics and counterfeits compared to PDA and MS data separately.&lt;/p&gt;</p

    ATR-FTIR spectroscopy and chemometrics : an interesting tool to discriminate and characterize counterfeit medicines

    No full text
    &lt;p&gt;Counterfeit medicines pose a huge threat to public health worldwide. High amounts of counterfeit pharmaceuticals enter the European market and therefore detection of these products is essential. Attenuated Total Reflection Fourier-Transform infrared spectroscopy (ATR-FTIR) might be useful for the screening of counterfeit medicines since it is easy to use and little sample preparation is required. Furthermore, this approach might be helpful to customs to obtain a first evaluation of suspected samples. This study proposes a combination of ATR-FTIR and chemometrics to discriminate and classify counterfeit medicines. A sample set, containing 209 samples in total, was analyzed using ATR-FTIR and the obtained spectra were used as fingerprints in the chemometric data-analysis which included Principal Component Analysis (PCA), k-Nearest Neighbours (k-NN), Classification and Regression Trees (CART) and Soft Independent Modelling of Class Analogy (SIMCA). First it was verified whether the mentioned techniques are capable to distinguish samples containing different active pharmaceutical ingredients (APIs). PCA showed a clear tendency of discrimination based on the API present; k-NN, CART and SIMCA were capable to create suitable prediction models based on the presence of different APIs. However k-NN performs the least while SIMCA performs the best. Secondly, it was tested whether these three models could be expanded to discriminate between genuine and counterfeit samples as well. k-NN was not able to make the desired discrimination and therefore it was not useful. CART performed better but also this model was less suited. SIMCA, on the other hand, resulted in a model with a 100% correct discrimination between genuine and counterfeit drugs. This study shows that chemometric analysis of ATR-FTIR fingerprints is a valuable tool to discriminate genuine from counterfeit samples and to classify counterfeit medicines.&lt;/p&gt;</p
    corecore