57 research outputs found

    heat as a tracer

    Get PDF
    Not available

    The EU project Cheap-GSHPs

    Get PDF
    Not available

    Laboratory thermal conductivity measurements on gravel sample

    Get PDF
    Modern Ground Source Heat Pumps (GSHPs) systems must be designed by taking into account the ground thermal properties, in order to properly plan the capability of the heat pumps to transfer calories through the Ground Source Heat Exchangers (GSHE) to the subsoil (and vice versa). [...

    Laboratory Measurements of Gravel Thermal Conductivity: An Update Methodological Approach

    Get PDF
    Abstract Direct measurements of gravel thermal properties are usually quite challenging to be performed in laboratory, due to the very coarse sediments size. As a consequence, the reference thermal values provided by literature for gravels are quite limited and dispersed. A guarded hot plate Taurus Instruments TLP 800, usually used for measuring the thermal conductivity of buildings materials, was slightly modified in order to measure the thermal conductivity of some gravel samples. The tests were performed both in dry and wet conditions. The paper presents the first obtained results

    Soil thermal conductivity from early TRT logs using an active hybrid optic fibre system

    Get PDF
    At the Molinella test site in Italy, a monitoring well has been equipped with a hybrid active optical fibre cable down to the depth of 100 m sealed with geothermal grouting. The cored borehole provided a full stratigraphic sequence of unconsolidated alluvial deposits. The cored material has been classified from a geotechnical point of view, and the thermal parameters of the most relevant lithologies have been directly measured. Active heating of the optical fibre cable has been provided by a constant heating power injected through copper wires contained within the cable structure. This way, not only the equivalent thermal conductivity of the entire stratigraphy but also the thermal conductivity at a spatial resolution of 1 m have been obtained. For each investigated layer, the thermal conductivity obtained from the distributed temperature measurements and the ones acquired using direct measurements are interpreted and compared

    ground source heat pump systems in historical buildings two italian case studies

    Get PDF
    Abstract Reducing the energy demand of buildings has become one of the key points of the European Union. The issue related to the air conditioning of old and historical buildings is nowadays one of the most important field of operation for the primary energy saving and, at the same time, for the reduction of the CO 2 emission. The recent development of heat pump able to rise the supply of high temperature at the condenser side makes this technology suitable for the application also in historical buildings that are characterized by low thermal insulation and high thermal capacitance. In this context, the ground source heat pump systems can be used for both heating and cooling. The aim of this work is to analyze the thermal behavior of two historical buildings located in Italy, in Venice and Florence respectively. Detailed computer simulations of the buildings have been carried out by means of a transient calculation tool TRNSYS. Energy simulations of GSHP systems have been performed and a comparison with a common plant system using a gas boiler for heating and air-to-water chiller for cooling has been carried out

    An updated ground thermal properties database for GSHP applications

    Get PDF
    Abstract When a new ground source heat exchanger field is planned, underground thermal properties input data are necessary for the correct sizing of the geo-exchange system. To support the design, the EU founded Cheap-GSHPs project developed a Decision Support System, that comprises a new database of thermal properties for both rocks and unconsolidated sediments. The thermal properties database has been developed by integrating and comparing data (1) provided by the most important international guidelines, (2) acquired from a wide literature review and (3) obtained from more than 400 direct measurements. The data are mainly thermal conductivity data, hence the convective contribution provided by groundwater flow to heat transfer is not included. This paper presents and analyses the collected database
    • …
    corecore