366 research outputs found

    NASA HRP Immunology Discipline - Use of Terrestrial Analogs

    Get PDF
    Due to the cost and operational constraints, as well as technical implementation limitations, it is desirous to perform relevant space physiology investigations first in terrestrial 'space analogs'. This is particularly true for initial investigations, which may then provide appropriate focus for subsequent flight investigations, or for mechanistic investigations that simply cannot be performed during spaceflight. Appropriate analog choice is extremely important. There are a wide variety of terrestrial space analogs, each relevant to a particular physiological discipline (or disciplines) and each with a particular fidelity (or lack thereof) to spaceflight, and each with unique operational constraints. The HRP Immunology Discipline is tasked with managing the HRP Risk concerning clinical risk for Astronaut crews related to spaceflight-associated immune dysregulation. Such dysregulation has been documented to occur during spaceflight, and found to persist for the duration of a 6-month ISS mission. Studies continue to characterize the onorbit phenomenon, but it generally consists of diminished immunocyte function, dysregulated cytokine profiles, and persistent herpesvirus reactivation. Causes are thought to synergistically include microgravity, psychological or physiological stress, radiation, and/or circadian misalignment. An appropriate terrestrial analog for immune dysregulation would replicate as many of these influences as possible. Such analogs may include clinostat or bioreactor cell culture (microgravity), hindlimb suspension (stress, fluid shifts, hypokinesis), or human deployment to remote or extreme environments (isolation, stress, circadian). Also, the laboratory setting may be used as an analog, or to augment analogs, such as sleep deprivation/misalignment or human centrifugation to replicate gravitational stress. As an appropriate example of a NASA Disciplines use of Terrestrial space analogs, this talk will discuss spaceflight associated immune dysregulation, terrestrial immune analogs, and recent analog investigations

    Evidence Report: Risk of Crew Adverse Health Event Due to Altered Immune Response

    Get PDF
    The Risk of Crew Adverse Health Event Due to Altered Immune Response is identified by the National Aeronautics and Space Administration (NASA) Human Research Program (HRP) as a recognized risk to human health and performance in space. The HRP Program Requirements Document (PRD) defines these risks. This Evidence Report provides a summary of the evidence that has been used to identify and characterize this risk. It is known that human immune function is altered in and postflight, but it is unclear at present if such alterations lead to increased susceptibility to disease. Reactivation of latent viruses has been documented in crewmembers, although this reactivation has not been directly correlated with immune changes or with observed diseases. As described in this report, further research is required to better characterize the relationships between altered immune response and susceptibility to disease during and after spaceflight. This is particularly important for future deepspace exploration missions

    Whole Blood Activation Results in Enhanced Detection of T Cell and Monocyte Cytokine Production by Flow Cytometry

    Get PDF
    An excellent monitor of the immune balance of peripheral circulating cells is to determine their cytokine production patterns in response to stimuli. Using flow cytometry a positive identification of cytokine producing cells in a mixed culture may be achieved. Recently, the ability to assess cytokine production following a wholeblood activation culture has been described. We compared whole blood culture to standard PBMC culture and determined the individual cytokine secretion patterns for both T cells and monocytes via flow cytometry. For T cells cytokine assessment following PMA +ionomycin activation: (1) a significantly greater percentages of T cells producing IFNgamma and IL-2 were observed following whole-blood culture; (2) altered T cell cytokine production kinetics were observed by varying whole blood culture times. In addition, a four-color cytometric analysis was used to allow accurate phenotyping and quantitation of cytokine producing lymphocyte populations. Using this technique we found IFNgamma production to be significantly elevated in the CD3+/CD8+ T cell population as compared to the CD3+/CD8- population following five hours of whole blood activation. Conversely, IL-2 and IL-10 production were significantly elevated in the CD3+/CD8- T cell population as compared to the CD3+/CD8+ population. Monocyte cytokine production was assessed in both culture systems following LPS activation for 24 hours. A three-color flow cytometric was used to assess two cytokines in conjunction with CD 14. The cytokine pairs used for analysis were IL-1a/IL-12, and IL-10ITNFa. Nearly all monocytes were stimulated to produce IL-1a, IL-12 and TNFalpha equally well in both culture systems. Monocyte production of IL-10 was significantly elevated following whole blood culture as compared to PBMC culture. IL-12 producing monocytes appeared to be a distinct subpopulation of the IL-1a producing set, whereas IL-10 and TNFa producing monocytes were largely mutually exclusive. IL-10 and TNFa producing monocytes may represent functionally different monocyte subsets with distinct functions. Whole blood culture eliminates the need to purify cell populations prior to culture and may have significant utility for the routine monitoring of the cytokine balances of the peripheral blood T cell and monocyte populations. In addition, there are distinct advantages to performing whole-blood (WB) activation as compared to PBMC activation. These advantages would include retaining all various cell-cell interactions as well as any soluble factors present in serum that influence cell activation. It is likely that the altered cytokine production observed following whole blood culture more accurately represents the in-vivo immune balance

    Medical Concerns for Exploration Class Space Missions

    Get PDF
    No abstract availabl

    Whole Blood Activation Results in Altered T Cell and Monocyte Cytokine Production Profiles by Flow Cytometry

    Get PDF
    An excellent monitor of the immune balance of peripheral circulating cells is to determine their cytokine production patterns in response to stimuli. Using flow cytometry, a positive identification of cytokine producing cells in a mixed culture may be achieved. Recently, the ability to assess cytokine production following a whole-blood activation culture has been described. In this study, whole blood activation was compared to traditional PBMC activation and the individual cytokine secretion patterns for both T cells, T cell subsets and monocytes was determined by flow cytometry. RESULTS: For T cell cytokine assessment (IFNg/IL-10 and IL-21/L-4) following PMA +ionomycin activation: (1) a Significantly greater percentages of T cells producing IFNgamma and IL-2 were observed following whole-blood culture and (2) altered T cell cytokine production kinetics were observed by varying whole blood culture times. Four-color analysiS was used to allow assessment of cytokine production by specific T cell subsets. It was found that IFNgamma production was significantly elevated in the CD3+/CD8+ T cell population as compared to the CD3+/CD8- population following five hours of whole blood activation. Conversely, IL-2 and IL-10 production were Significantly elevated in the CD3+/CD8- T cell population as compared to the CD3+/CD8+ population. Monocyte cytokine production was assessed in both culture systems following LPS activation for 24 hours. A three-color flow cytometric was used to assess two cytokines (IL-1a/IL-12 and TNFa/IL-10) in conjunction with CD14. Nearly all monocytes were stimulated to produce IL-1a, IL-12 and TNFa. equally well in both culture systems, however monocyte production of IL-10 was significantly elevated in whole blood culture as compared to PBMC culture. IL-12 producing monocytes appeared to be a distinct subpopulation of the IL-1a producing set, whereas IL-10 and TNFa producing monocytes were largely mutually exclusive. IL-10 and TNFa producing monocytes may represent distinct monocyte subsets with unique functions. CONCLUSIONS: Whole blood culture eliminates the need to purify cell populations prior to culture and may have Significant utility for the routine monitoring of the cytokine balances of the peripheral blood T cell and monocyte populations. In addition, there are distinct advantages to performing whole-blood (WB) activation as compared to PBMC activation. These advantages would include retaining all various cell-cell interactions as well as any soluble factors present in serum that influence cell activation. In this study, alterations in cytokine production are demonstrated between whole blood and PBMC activation. It is likely that whole blood activation more accurately represents the in-vivo immune balance than PBMC activation

    Effects of radiation on immune system and latent virus reactivation

    Get PDF
    The purpose of this NCRP commentary is to provide the current state of knowledge on the effects of ionizing radiation on the immune system and on latent herpes virus reactivation to the scientific community and government agencies. Its purpose is to better understand radiation-induced latent virus reactivation, which is possibly an underestimated consequence of ionizing radiation exposure. This activity should involve the radiation research community (academia, industry and regulatory agencies) and government agencies (NASA, DOD, CDC)

    Risk of Crew Adverse Health Event Due to Altered Immune Response

    Get PDF
    Determining the effect of space travel on the human immune system has proven to be extremely challenging. Limited opportunities for in-flight studies, varying mission durations, technical and logistical obstacles, small subject numbers, and a broad range of potential assays have contributed to this problem. Additionally, the inherent complexity of the immune system, with its vast array of cell populations, sub-populations, diverse regulatory molecules, and broad interactions with other physiological systems, makes determining precise variables to measure very difficult. There is also the challenge of determining the clinical significance of any observed immune alterations. Will such a change lead to disease, or is it a transient subclinical observation related to short-term stress? The effect of this problem may be observed by scanning publications associated with immunity and spaceflight, which began to appear during the 1970s. Although individually they are each valid studies, the comprehensive literature to date suffers from widely varying sampling methods and assay techniques, low subject counts, and sometimes a disparate focus on narrow aspects of immunity. The most clinically relevant data are derived from in-flight human studies, which have demonstrated altered cell-mediated immunity and reactivation of latent herpes viruses. Much more data are available from post-flight testing of humans, with clear evidence of altered cytokine production patterns, altered leukocyte distribution, continued latent viral reactivation, and evidence of dramatically altered virus-specific immunity. It is unknown if post-flight assessments relate to the in-flight condition or are a response to landing stress and readaptation. In-flight culture of cells has clearly demonstrated that immune cells are gravity-sensitive and display altered functional characteristics. It is unknown if these data are related to in vivo immune cell function or are an artifact of microgravity culture. Ground analog testing of humans and animals, as well as microgravity-analog cell culture, has demonstrated utility. However, in all cases, it is not known with certainty if these data would reflect similar testing during space travel. Given their ready availability, ground analogs may be extremely useful for assay development and the evaluation of potential countermeasures. In general, the evidence base suffers from widely disparate studies on small numbers of subjects that do not directly correlate well with each other or spaceflight itself. Also lacking are investigations of the effect of gender on adaption to spaceflight. This results in significant knowledge 'gaps' that must be filled by future studies to completely determine any clinical risk related to immunity for human exploration-class space missions. These gaps include a significant lack of in-flight data, particularly during long-duration space missions. The International Space Station represents an excellent science platform with which to address this knowledge gap. Other knowledge gaps include lack of a single validated ground analog for the phenomenon and a lack of flight-compatible laboratory equipment capable of monitoring astronauts (for either clinical or research purposes). However, enough significant data exist, as described in this manuscript, to warrant addressing this phenomenon during the utilization phase of the ISS. A recent Space Shuttle investigation has confirmed the 31 in-flight nature of immune dysregulation, demonstrating that it is not merely a post-flight phenomenon. Several current studies are ongoing onboard the ISS that should thoroughly characterize the phenomenon. NASA recognizes that if spaceflight-associated immune dysregulation persists during exploration flights in conjunction with other dangers, such as high-energy radiation, the result may be a significant clinical risk. This emphasizes the need for a continued integrated comprehensive approach to determining the effect of prolonged spaceflight, separated from transient launch and landing stresses, on human immunity. After such studies, the phenomenon will be understood, and, hopefully, a monitoring strategy will have been developed that could be used to monitor the effectiveness of countermeasur

    Medical and Scientific Evaluations aboard the KC-135. Microgravity-Compatible Flow Cytometer

    Get PDF
    A spaceflight-compatible flow cytometer would be useful for the diagnosis of astronaut illness during long duration spaceflight and for conducting in-flight research to evaluate the effects of microgravity on human physiology. Until recently, the primary limitations preventing the development of a spaceflight compatible flow cytometer have been largely mechanical. Standard commercially available flow cytometers are large, complex instruments that use high-energy lasers and require significant training to operate. Standard flow cytometers function by suspending the particles to be analyzed inside a sheath fluid for analysis. This requires the presence of several liters of sheath fluid for operation, and generates a corresponding amount of liquid hazardous waste. The particles are then passed through a flow cell which uses the fluid mechanical property of hydrodynamic focusing to place the cells in single-file (laminar flow) as they pass through a laser beam for scanning and evaluation. Many spaceflight experiments have demonstrated that fluid physics is dramatically altered in microgravity (MSF [Manned Space Flight] Fluid Physics Data Sheet-August 1997) and previous studies have shown that sheath-fluid based hydrodynamic focusing may also be altered during microgravity (Crucian et al, 2000). For these reasons it is likely that any spaceflight compatible design for a flow cytometer would abandon the sheath fluid requirement. The elimination of sheath fluid would remove both the problems of weight associated with large volumes of liquids as well as the large volume of liquid waste generated. It would also create the need for a method to create laminar particle flow distinct from the standard sheath-fluid based method. The spaceflight prototype instrument is based on a recently developed commercial flow cytometer possessing a novel flow cell design that creates single-particle laser scanning and evaluation without the need for sheath-fluid based hydrodynamic focusing. This instrument also possesses a number of design advances that make it conditionally microgravity compatible: it is highly miniaturized and lightweight, uses a low energy diode laser, has a small number of moving parts, does not use sheath fluid and does not generate significant liquid waste. Although possessing certain limitations, the commercial cytometer functions operationally like a standard bench top laboratory flow cytometer, aspirating liquid particle samples and generating histogram or dot-plot data in standard FCS file format. In its current configuration however, the cytometer is limited to three parameter/two-color capability (two color PMTs + forward scatter), does not allow compensation between colors, does not allow linear analysis and is operated by rather inflexible software with limited capabilities. This is due to the fact that the cytometer has been designed and marketed as an instrument specific to a few particular assays, not as a multipurpose cytometer

    Micron2 Lab: Microfluidic Microbiology Lab Project

    Get PDF
    Microbial monitoring during spaceflight is crucial to maintain crew health and ensure water purifications systems are functioning properly. Current protocols for in-flight enumeration of bacteria in potable water systems require culture based methods. In this project, we aim to develop a flight- and microgravity-compatible flow cytometer capable of counting total microbial counts in the water supply and differentiating live from dead bacteria
    corecore