25 research outputs found

    Algorithm to improve the diagnosis of paraneoplastic neurological syndromes associated with SOX1 antibodies

    Get PDF
    Cell-based assay; Paraneoplastic neurological syndromes; Small-cell lung cancerAssaig basat en cèl·lules; Síndromes neurològiques paraneoplàstiques; Càncer de pulmó de cèl·lules petitesEnsayo basado en células; Síndromes neurológicos paraneoplásicos; Cáncer de pulmón de células pequeñasSOX1 antibodies (SOX1-abs) are associated with paraneoplastic neurological syndromes (PNS) and small cell lung cancer (SCLC). In many clinical laboratories SOX1-abs are determined by commercial line blots without confirmation by cell-based assay (CBA) with HEK293 cells expressing SOX1. However, the diagnostic yield of commercial line blots is low and the accessibility to the CBA, that is not commercially available, limited. Here, we evaluated if the addition of the band intensity data of the line blot and the immunoreactivity in a tissue-based assay (TBA) improve the diagnostic performance of the line blot. We examined serum of 34 consecutive patients with adequate clinical information that tested positive for SOX1-abs in a commercial line blot. Samples were also assessed by TBA and CBA. SOX1-abs were confirmed by CBA in 17 (50%) patients, all (100%) had lung cancer (SCLC in 16) and 15/17 (88%) had a PNS. In the remaining 17 patients the CBA was negative and none had PNS associated with lung cancer. TBA was assessable in 30/34 patients and SOX1-abs reactivity was detected in 15/17 (88%) with positive and in 0/13 (0%) with negative CBA. Only 2 (13%) of the 15 TBA-negative patients were CBA-positive. The frequency of TBA-negative but CBA-positive increased from 10% (1/10) when the band intensity of the line blot was weak to 20% (1/5) in patients with a moderate or strong intensity band. Confirmation by CBA should be mandatory for samples (56% in this series) not assessable (4/34; 12%) or negative in the TBA (15/34; 44%).This study was funded by Instituto de Salud Carlos III - Subdirección General de Evaluación y Formento de la Investigación Sanitaria and co-funded by European Union, FIS (PI21/00255, RR-G)

    Algorithm to improve the diagnosis of paraneoplastic neurological syndromes associated with SOX1 antibodies

    Get PDF
    SOX1 antibodies (SOX1-abs) are associated with paraneoplastic neurological syndromes (PNS) and small cell lung cancer (SCLC). In many clinical laboratories SOX1-abs are determined by commercial line blots without confirmation by cell-based assay (CBA) with HEK293 cells expressing SOX1. However, the diagnostic yield of commercial line blots is low and the accessibility to the CBA, that is not commercially available, limited. Here, we evaluated if the addition of the band intensity data of the line blot and the immunoreactivity in a tissue-based assay (TBA) improve the diagnostic performance of the line blot. We examined serum of 34 consecutive patients with adequate clinical information that tested positive for SOX1-abs in a commercial line blot. Samples were also assessed by TBA and CBA. SOX1-abs were confirmed by CBA in 17 (50%) patients, all (100%) had lung cancer (SCLC in 16) and 15/17 (88%) had a PNS. In the remaining 17 patients the CBA was negative and none had PNS associated with lung cancer. TBA was assessable in 30/34 patients and SOX1-abs reactivity was detected in 15/17 (88%) with positive and in 0/13 (0%) with negative CBA. Only 2 (13%) of the 15 TBA-negative patients were CBA-positive. The frequency of TBA-negative but CBA-positive increased from 10% (1/10) when the band intensity of the line blot was weak to 20% (1/5) in patients with a moderate or strong intensity band. Confirmation by CBA should be mandatory for samples (56% in this series) not assessable (4/34; 12%) or negative in the TBA (15/34; 44%)

    CAR-T after Stem Cell Transplantation in B-Cell Lymphoproliferative Disorders: Are They Really Autologous or Allogenic Cell Therapies?

    No full text
    Allogenic hematopoietic stem cell transplantation (allo-HSCT) is one of the standard treatments for B-cell lymphoproliferative disorders; however, deep relapses are common after an allo-HSCT, and it is associated with poor prognosis. A successful approach to overcome these relapses is to exploit the body’s own immune system with chimeric antigen receptor (CAR) T-cells. These two approaches are potentially combinatorial for treating R/R B-cell lymphoproliferative disorders. Several clinical trials have described different scenarios in which allo-HSCT and CAR-T are successively combined. Further, for all transplanted patients, assessment of chimerism is important to evaluate the engraftment success. Nonetheless, for those patients who previously received an allo-HSCT there is no monitorization of chimerism before manufacturing CAR T-cells. In this review, we focus on allo-HSCT and CAR-T treatments and the different sources of T-cells for manufacturing CAR T-cells

    Harmonized D-dimer levels upon admission for prognosis of COVID-19 severity: Results from a Spanish multicenter registry (BIOCOVID-Spain study).

    No full text
    Coagulopathy is a key feature of COVID-19 and D-dimer has been reported as a predictor of severity. However, because D-dimer test results vary considerably among assays, resolving harmonization issues is fundamental to translate findings into clinical practice. In this retrospective multicenter study (BIOCOVID study), we aimed to analyze the value of harmonized D-dimer levels upon admission for the prediction of in-hospital mortality in COVID-19 patients. All-cause in-hospital mortality was defined as endpoint. For harmonization of D-dimer levels, we designed a model based on the transformation of method-specific regression lines to a reference regression line. The ability of D-dimer for prediction of death was explored by receiver operating characteristic curves analysis and the association with the endpoint by Cox regression analysis. Study population included 2663 patients. In-hospital mortality rate was 14.3%. Harmonized D-dimer upon admission yielded an area under the curve of 0.66, with an optimal cut-off value of 0.945 mg/L FEU. Patients with harmonized D-dimer ≥ 0.945 mg/L FEU had a higher mortality rate (22.4% vs. 9.2%; p

    Cardiac troponin and COVID-19 severity: Results from BIOCOVID study.

    No full text
    Myocardial injury is a common finding in COVID-19 strongly associated with severity. We analysed the prevalence and prognostic utility of myocardial injury, characterized by elevated cardiac troponin, in a large population of COVID-19 patients, and further evaluated separately the role of troponin T and I. This is a multicentre, retrospective observational study enrolling patients with laboratory-confirmed COVID-19 who were hospitalized in 32 Spanish hospitals. Elevated troponin levels were defined as values above the sex-specific 99th percentile upper reference limit, as recommended by international guidelines. Thirty-day mortality was defined as endpoint. A total of 1280 COVID-19 patients were included in this study, of whom 187 (14.6%) died during the hospitalization. Using a nonspecific sex cut-off, elevated troponin levels were found in 344 patients (26.9%), increasing to 384 (30.0%) when a sex-specific cut-off was used. This prevalence was significantly higher (42.9% vs 21.9%; P  In this multicentre study, myocardial injury was a common finding in COVID-19 patients. Its prevalence increased when a sex-specific cut-off and cardiac troponin T were used. Elevated troponin was an independent predictor of 30-day mortality, irrespective of cardiac troponin assay and cut-offs to detect myocardial injury. Hence, the early measurement of cardiac troponin may be useful for risk stratification in COVID-19

    Characteristics and laboratory findings on admission to the emergency department among 2873 hospitalized patients with COVID-19: the impact of adjusted laboratory tests in multicenter studies. A multicenter study in Spain (BIOCOVID-Spain study).

    No full text
    Identification of predictors for severe disease progression is key for risk stratification in COVID-19 patients. We aimed to describe the main characteristics and identify the early predictors for severe outcomes among hospitalized patients with COVID-19 in Spain. This was an observational, retrospective cohort study (BIOCOVID-Spain study) including COVID-19 patients admitted to 32 Spanish hospitals. Demographics, comorbidities and laboratory tests were collected. Outcome was in-hospital mortality. For analysis, laboratory tests values were previously adjusted to assure the comparability of results among participants. Cox regression was performed to identify predictors. Study population included 2873 hospitalized COVID-19 patients. Nine variables were independent predictors for in-hospital mortality, including creatinine (Hazard ratio [HR]:1.327; 95% Confidence Interval [CI]: 1.040-1.695, p = .023), troponin (HR: 2.150; 95% CI: 1.155-4.001; p = .016), platelet count (HR: 0.994; 95% CI: 0.989-0.998; p = .004) and C-reactive protein (HR: 1.037; 95% CI: 1.006-1.068; p = .019). This is the first multicenter study in which an effort was carried out to adjust the results of laboratory tests measured with different methodologies to guarantee their comparability. We reported a comprehensive information about characteristics in a large cohort of hospitalized COVID-19 patients, focusing on the analytical features. Our findings may help to identify patients early at a higher risk for an adverse outcome

    Highly-parallelized simulation of a pixelated LArTPC on a GPU

    No full text
    The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on 10310^3 pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype

    The DUNE Far Detector Vertical Drift Technology, Technical Design Report

    No full text
    International audienceDUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise. In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered. This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals

    The DUNE Far Detector Vertical Drift Technology, Technical Design Report

    No full text
    International audienceDUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise. In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered. This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals
    corecore