258 research outputs found

    Breast cancer radiotherapy and the risk of acute coronary events - insights from a process oriented model

    Get PDF
    BACKGROUND AND PURPOSE: Acute coronary events (ACEs) are considered the most important side effect of radiotherapy (RT) for breast cancer but underlying mechanisms still have to be identified. Process oriented models mathematically describe the development of disease and provide a link between mechanisms and subsequent risk. Here, this link is exploited to learn about the underlying mechanisms from the observed age-time patterns of ACE risk. MATERIALS AND METHODS: A process oriented model of atherosclerosis and subsequent ACEs was applied to a contemporary breast cancer cohort of 810 patients with measurements of coronary artery calcification. Patients with prior ischemic heart disease were excluded. The process oriented model describes disease development as a series of different stages. Different variants of the model were fitted to the data. In each variant, one stage was assumed to be accelerated in relation to mean heart dose. RESULTS: During a mean follow up of 9.1 years, 25 ACEs occurred. The model reproduced the prevalence and associated risk of coronary calcifications. Mean heart dose significantly improved the fit only when implemented as affecting a late stage of atherosclerosis on already existing, complicated lesions (achieving p = 0.007). This can be understood by atherosclerosis being a slowly progressing disease. Therefore, an increase of ACEs few years after RT requires advanced atherosclerosis at the time of RT. CONCLUSION: Risk of ACE increases within few years in patients with advanced atherosclerosis at RT. Therefore, patients should be assessed for cardiovascular risk, and also elderly patients need to be considered for heart sparing techniques

    Effecto: Op weg naar effectief ondernemerschapsonderwijs in Vlaanderen

    Get PDF
    Performance assessment of innovation projects is a central issue in innovation management research. Using existing literature, a model is developed to assess the performance of new product and new service development projects. In this model, project performance is defined as a combination of a formatively indicated operational performance construct and a reflectively indicated product performance construct. The validity of this model is tested based on a sample of 219 innovation projects assessed by innovation managers. Using only the innovation managers' responses, it is, however, not possible to distinguish between operational and product performance. The impact of common method bias and informant bias is subsequently assessed using a subsample of 128 of these 219 innovation projects that are assessed by the innovation manager and the project leader. These latter results show that operational and product performance are two distinct constructs. In addition, the multitrait–multimethod analyses show that especially the more abstract items of performance, such as the perceptions of quality, captured knowledge, competitive advantage, gained reputation, and customer satisfaction, suffer from random error and informant bias. Project leaders appear to be better informed to assess operational performance, while innovation managers are better in assessing product performance. The paper concludes with a qualitative comparison of several alternative performance models: the project performance model as derived from the literature, a similar (misspecified) reflective performance model, two stand-alone models in which operational and product performance are assessed separately, and a mixed model that uses a combination of innovation managers' and project managers' data. Based on this comparison, it is advised to use either the stand-alone models for operational performance and product performance or the mixed model whereby the project leader assesses operational performance and the innovation manager the product performance of an innovation project

    Evaluation of interplay and organ motion effects by means of 4D dose reconstruction and accumulation

    Get PDF
    PURPOSE: Pencil beam scanned proton therapy (PBS-PT) treatment quality might be compromised by interplay and motion effects. Via fraction-wise reconstruction of 4D dose distributions and dose accumulation, we assess the clinical relevance of motion related target dose degradation in thoracic cancer patients. METHODS AND MATERIALS: For the ten thoracic patients (Hodgkin lymphoma and non-small cell lung cancer) treated at our proton therapy facility, daily breathing pattern records, treatment delivery log-files and weekly repeated 4DCTs were collected. Patients exhibited point-max target motion of up to 20 mm. They received robustly optimized treatment plans, delivered with five-times rescanning in fractionated regimen. Treatment delivery records were used to reconstruct 4D dose distributions and the accumulated treatment course dose per patient. Fraction-wise target dose degradations were analyzed and the accumulated treatment course dose, representing an estimation of the delivered dose, was compared with the prescribed dose. RESULTS: No clinically relevant loss of target dose homogeneity was found in the fraction-wise reconstructed 4D dose distributions. Overall, in 97% of all reconstructed fraction doses, D98 remained within 5% from the prescription dose. The V95 of accumulated treatment course doses was higher than 99.7% for all ten patients. CONCLUSIONS: 4D dose reconstruction and accumulation enables the clinical estimation of actual exhibited interplay and motion effects. In the patients considered here, the loss of homogeneity caused by interplay and organ motion did not show systematic pattern and smeared out throughout the course of fractionated PBS-PT treatment. Dose degradation due to anatomical changes showed to be more severe and triggered treatment adaptations for five patients

    Bicuspid Aortic Valve Stenosis and the Effect of Vitamin K2 on Calcification Using F-Sodium Fluoride Positron Emission Tomography/Magnetic Resonance:The BASIK2 Rationale and Trial Design

    Get PDF
    BASIK2 is a prospective, double-blind, randomized placebo-controlled trial investigating the effect of vitamin K2 (menaquinone-7;MK7) on imaging measurements of calcification in the bicuspid aortic valve (BAV) and calcific aortic valve stenosis (CAVS). BAV is associated with early development of CAVS. Pathophysiologic mechanisms are incompletely defined, and the only treatment available is valve replacement upon progression to severe symptomatic stenosis. Matrix Gla protein (MGP) inactivity is suggested to be involved in progression. Being a vitamin K dependent protein, supplementation with MK7 is a pharmacological option for activating MGP and intervening in the progression of CAVS. Forty-four subjects with BAV and mild–moderate CAVS will be included in the study, and baseline 18F-sodiumfluoride (18F-NaF) positron emission tomography (PET)/ magnetic resonance (MR) and computed tomography (CT) assessments will be performed. Thereafter, subjects will be randomized (1:1) to MK7 (360 mcg/day) or placebo. During an 18-month follow-up period, subjects will visit the hospital every 6 months, undergoing a second 18F-NaF PET/MR after 6 months and CT after 6 and 18 months. The primary endpoint is the change in PET/MR 18F-NaF uptake (6 months minus baseline) compared to this delta change in the placebo arm. The main secondary endpoints are changes in calcium score (CT), progression of the left ventricularremodeling response and CAVS severity (echocardiography). We will also examine the association between early calcification activity (PET) and later changes in calcium score (CT)

    Pupillary Responses to High-Irradiance Blue Light Correlate with Glaucoma Severity

    Get PDF
    PurposeTo evaluate whether a chromatic pupillometry test can be used to detect impaired function of intrinsically photosensitive retinal ganglion cells (ipRGCs) in patients with primary open-angle glaucoma (POAG) and to determine if pupillary responses correlate with optic nerve damage and visual loss.DesignCross-sectional study.ParticipantsOne hundred sixty-one healthy controls recruited from a community polyclinic (55 men; 151 ethnic Chinese) and 40 POAG patients recruited from a glaucoma clinic (22 men; 35 ethnic Chinese) 50 years of age or older.MethodsSubjects underwent monocular exposure to narrowband blue light (469 nm) or red light (631 nm) using a modified Ganzfeld dome. Each light stimulus was increased gradually over 2 minutes to activate sequentially the rods, cones, and ipRGCs that mediate the pupillary light reflex. Pupil diameter was recorded using an infrared pupillography system.Main Outcome MeasuresPupillary responses to blue light and red light were compared between control subjects and those with POAG by constructing dose-response curves across a wide range of corneal irradiances (7–14 log photons/cm2 per second). In patients with POAG, pupillary responses were evaluated relative to standard automated perimetry testing (Humphrey Visual Field [HVF]; Carl Zeiss Meditec, Dublin, CA) and scanning laser ophthalmoscopy parameters (Heidelberg Retinal Tomography [HRT]; Heidelberg Engineering, Heidelberg, Germany).ResultsThe pupillary light reflex was reduced in patients with POAG only at higher irradiance levels, corresponding to the range of activation of ipRGCs. Pupillary responses to high-irradiance blue light associated more strongly with disease severity compared with responses to red light, with a significant linear correlation observed between pupil diameter and HVF mean deviation (r = −0.44; P = 0.005) as well as HRT linear cup-to-disc ratio (r = 0.61; P < 0.001) and several other optic nerve head parameters.ConclusionsIn glaucomatous eyes, reduced pupillary responses to high-irradiance blue light were associated with greater visual field loss and optic disc cupping. In POAG, a short chromatic pupillometry test that evaluates the function of ipRGCs can be used to estimate the degree of damage to retinal ganglion cells that mediate image-forming vision. This approach could prove useful in detecting glaucoma

    A biological question and a balanced (orthogonal) design: the ingredients to efficiently analyze two-color microarrays with Confirmatory Factor Analysis

    Get PDF
    BACKGROUND: Factor analysis (FA) has been widely applied in microarray studies as a data-reduction-tool without any a-priori assumption regarding associations between observed data and latent structure (Exploratory Factor Analysis). A disadvantage is that the representation of data in a reduced set of dimensions can be difficult to interpret, as biological contrasts do not necessarily coincide with single dimensions. However, FA can also be applied as an instrument to confirm what is expected on the basis of pre-established hypotheses (Confirmatory Factor Analysis, CFA). We show that with a hypothesis incorporated in a balanced (orthogonal) design, including 'SelfSelf' hybridizations, dye swaps and independent replications, FA can be used to identify the latent factors underlying the correlation structure among the observed two-color microarray data. An orthogonal design will reflect the principal components associated with each experimental factor. We applied CFA to a microarray study performed to investigate cisplatin resistance in four ovarian cancer cell lines, which only differ in their degree of cisplatin resistance. RESULTS: Two latent factors, coinciding with principal components, representing the differences in cisplatin resistance between the four ovarian cancer cell lines were easily identified. From these two factors 315 genes associated with cisplatin resistance were selected, 199 genes from the first factor (False Discovery Rate (FDR): 19%) and 152 (FDR: 24%) from the second factor, while both gene sets shared 36. The differential expression of 16 genes was validated with reverse transcription-polymerase chain reaction. CONCLUSION: Our results show that FA is an efficient method to analyze two-color microarray data provided that there is a pre-defined hypothesis reflected in an orthogonal design
    corecore